期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
水波泵内流体径向平衡问题的解法
1
作者 陶毅 刘英学 刘高联 《上海大学学报(自然科学版)》 CAS CSCD 2003年第4期361-364,共4页
该文分析了不可压流体在转子进出口的径向平衡问题,对不同的径向流模型进行了讨论,得到满足径向平衡条件的解析解,并对新型水泵——水波泵的进、出口进行了分析计算,为完成水波泵的设计方案提供了依据.
关键词 径向平衡 水波泵 不可压缩流动
下载PDF
水波泵的流体力学原理与设计计算 被引量:7
2
作者 刘英学 陶毅 刘高联 《流体机械》 CSCD 2003年第10期15-18,共4页
阐述了一种新型水泵———水波泵的工作原理与功能 ,并通过流体力学计算得出了该泵的主要设计参数。该泵的研制对于自然水力资源或工业与民用水循环系统废弃能量的利用具有良好的经济和社会效益。
关键词 一维非定常流 水波理论 气波增压器 水锤 水波泵
下载PDF
Pressure fluctuation and its influencing factors in circulating water pump 被引量:12
3
作者 代翠 孔繁余 董亮 《Journal of Central South University》 SCIE EI CAS 2013年第1期149-155,共7页
In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbul... In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted. 展开更多
关键词 circulating water pump turbulence model sampling frequency sampling time pressure fluctuation
下载PDF
The feasibility experimental study of pumping and shunting pump under pressure in water injection station
4
作者 Dongbo SHAO Yong WANG Suiwang ZHANG 《International Journal of Technology Management》 2013年第3期34-37,共4页
At present in the process of water injection station operation, starting and stopping the pump caused system pressure fluctuations, and the fluctuations caused many problems about downstream injection wells. In order ... At present in the process of water injection station operation, starting and stopping the pump caused system pressure fluctuations, and the fluctuations caused many problems about downstream injection wells. In order to eliminate the fluctuations and reduce problems, taking start pump, connect pump test under pressure in the water injection station installed the rotor frequency control system Changqing oil field developed. During the experiment, by progressively increasing the pressure pump to verify start pump with pressure feasibility test, the result shows when the pressure in the 0-25MPa pressure start and connect pump can be realized, and forecast the maximum pressure of the current start of the station with pressure pump. Start pump with pressure achieve the elimination of pressure fluctuations, provide the prerequisites about realizeing stable water injection pressure, and ultimately realize oil field water injection station to be automatic water injection laid a foundation. 展开更多
关键词 water injection station wire-wound motor pumping pump under pressure feasibility experiment
下载PDF
Dynamic analysis on pressure fluctuation in vaneless region of a pump turbine 被引量:6
5
作者 LI DeYou GONG RuZhi +3 位作者 WANG HongJie XIANG GaoMing WEI XianZhu LIU ZhanSheng 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2015年第5期813-824,共12页
As the pump turbine tends to be operated with high head and high rotational speed, the study of stability problems becomes more important. The pump turbine usually works at operating conditions where the guide vanes e... As the pump turbine tends to be operated with high head and high rotational speed, the study of stability problems becomes more important. The pump turbine usually works at operating conditions where the guide vanes experience strong vibrations. However, most traditional studies were carried out based on constant GVO(guide vane opening) simulations. In this work, dynamic analysis on pressure fluctuation in the vaneless region of a pump turbine model was conducted using a dynamic mesh method in turbine mode. 3D unsteady simulations were conducted where GVO was closed and opened by 1° from the initial 18°. Detailed time domain and frequency domain characteristics on pressure fluctuation in the vaneless region under different guide vane rotational states compared with constant GVO simulations were investigated. Results show that, during the guide vanes oscillating process, the low and intermediate frequency components in the vaneless region are significantly different. The amplitudes of pressure fluctuation are higher than those with constant GVO simulations, which agree better with the experimental data. In addition, the pressure fluctuation increases when GVO is opened, and vice versa. It can be concluded that pressure fluctuation in the vaneless region is strongly influenced by the oscillating of the guide vanes. 展开更多
关键词 fluctuation turbine agree unsteady listed operated opened creased Figure inlet
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部