Due to the phenomenon of abandoning wind power and photo voltage(PV)power in the“Three Northern Areas”in China,this paper presents an optimal strategy for coordinating and dispatching“source-load”in power system b...Due to the phenomenon of abandoning wind power and photo voltage(PV)power in the“Three Northern Areas”in China,this paper presents an optimal strategy for coordinating and dispatching“source-load”in power system based on multiple time scales.On the basis of the analysis of the uncertainty of wind power and PV power as well as the characteristics of load side resource dispatching,the optimal model of coordinating and dispatching“source-load”in power system based on multiple time scales is established.It can simultaneously and effectively dispatch conventional generators,wind plant,PV power station,pumped-storage power station and load side resources by optimally using three time scales:day-ahead,intra-day and real-time.According to the latest predicted information of wind power,PV power and load,the original generation schedule can be rolled and amended by using the corresponding time scale.The effectiveness of the model can be verified by a real system.The simulation results show that the proposed model can make full use of“source-load”resources to improve the ability to consume wind power and PV power of the grid-connected system.展开更多
Xiliaohe River watershed plays an important role in regional and national grain security.With the development of society and economy,water consumption that increased dramatically causes water shortages.Crop water requ...Xiliaohe River watershed plays an important role in regional and national grain security.With the development of society and economy,water consumption that increased dramatically causes water shortages.Crop water requirement can provide quantitative basis for making regional irrigation scheme.In this study,spring maize water requirement is calculated by using PenmanMonteith formula and spring maize coefficient from May to September at 10 meteorological stations in Xiliaohe River watershed from 1951 to 2005.The variation trend of the spring maize water requirement during the whole growing stage,water requirement in every month,and meteorological influencing factors are obtained by using Mann-Kendall method,and the degree of grey incidence between the water requirement and meteorological influencing factors are shown.The results are the spring maize water requirement during the whole growing stages increases at half of the stations in Xiliaohe River watershed,and are remarkably affected by the water requirement in May.The monthly mean,maximum and minimum air temperature form May to September show an increasing trend in Xiliaohe River watershed in recent 55 years.The monthly mean and minimum air temperature increases notably.The relative humidity,precipitation,wind speed and sunshine show a decreasing trend with variety for different months.The monthly maximum air temperature,wind speed,sunshine and monthly mean air temperature have the highest correlation degree with spring maize water requirement from May to September.展开更多
MHPPs (micro hydro power plants) have become prominent in hydropower plants as a solution to provide the energy demands of the grid. In this study, a new hybrid renewable energy based DC excitation system for synchr...MHPPs (micro hydro power plants) have become prominent in hydropower plants as a solution to provide the energy demands of the grid. In this study, a new hybrid renewable energy based DC excitation system for synchronous generator in the developed MHPP system is introduced. Proposed hybrid DC excitation system consists of solar & hydrogen energy based power generating systems. Hybrid renewable energy based system is used for the excitation of the synchronous generator in the MHPP test system. The renewables are used as a secondary energy source to provide the excitation current to a synchronous generator that generates energy in MHPP. A PV (photovoltaic) array is used as the main source of excitation, and a FC (fuel cell) stack is used for DC excitation in the lack of sunshine. In the experimental setup, an electrical control card is developed, and a microcontroller is used to perform the proposed excitation system. All experimental results obtained from 5 kW rated power MHHP test system. Experimental results show that, the proposed method provides the continuous excitation current, and the operation of the synchronous generator is uninterrupted. The proposed method is also practical and easily implemented for MHPP systems.展开更多
基金Major Projects of Gansu Province(No.17ZD2GA010)Power Company Technology Projects of State Grid Corporation in Gansu Province(No.52272716000K)
文摘Due to the phenomenon of abandoning wind power and photo voltage(PV)power in the“Three Northern Areas”in China,this paper presents an optimal strategy for coordinating and dispatching“source-load”in power system based on multiple time scales.On the basis of the analysis of the uncertainty of wind power and PV power as well as the characteristics of load side resource dispatching,the optimal model of coordinating and dispatching“source-load”in power system based on multiple time scales is established.It can simultaneously and effectively dispatch conventional generators,wind plant,PV power station,pumped-storage power station and load side resources by optimally using three time scales:day-ahead,intra-day and real-time.According to the latest predicted information of wind power,PV power and load,the original generation schedule can be rolled and amended by using the corresponding time scale.The effectiveness of the model can be verified by a real system.The simulation results show that the proposed model can make full use of“source-load”resources to improve the ability to consume wind power and PV power of the grid-connected system.
基金supported by Natural Science Foundation of China (Grant no.40771204,Grant no. 40801006 and Grant no.40801223)
文摘Xiliaohe River watershed plays an important role in regional and national grain security.With the development of society and economy,water consumption that increased dramatically causes water shortages.Crop water requirement can provide quantitative basis for making regional irrigation scheme.In this study,spring maize water requirement is calculated by using PenmanMonteith formula and spring maize coefficient from May to September at 10 meteorological stations in Xiliaohe River watershed from 1951 to 2005.The variation trend of the spring maize water requirement during the whole growing stage,water requirement in every month,and meteorological influencing factors are obtained by using Mann-Kendall method,and the degree of grey incidence between the water requirement and meteorological influencing factors are shown.The results are the spring maize water requirement during the whole growing stages increases at half of the stations in Xiliaohe River watershed,and are remarkably affected by the water requirement in May.The monthly mean,maximum and minimum air temperature form May to September show an increasing trend in Xiliaohe River watershed in recent 55 years.The monthly mean and minimum air temperature increases notably.The relative humidity,precipitation,wind speed and sunshine show a decreasing trend with variety for different months.The monthly maximum air temperature,wind speed,sunshine and monthly mean air temperature have the highest correlation degree with spring maize water requirement from May to September.
文摘MHPPs (micro hydro power plants) have become prominent in hydropower plants as a solution to provide the energy demands of the grid. In this study, a new hybrid renewable energy based DC excitation system for synchronous generator in the developed MHPP system is introduced. Proposed hybrid DC excitation system consists of solar & hydrogen energy based power generating systems. Hybrid renewable energy based system is used for the excitation of the synchronous generator in the MHPP test system. The renewables are used as a secondary energy source to provide the excitation current to a synchronous generator that generates energy in MHPP. A PV (photovoltaic) array is used as the main source of excitation, and a FC (fuel cell) stack is used for DC excitation in the lack of sunshine. In the experimental setup, an electrical control card is developed, and a microcontroller is used to perform the proposed excitation system. All experimental results obtained from 5 kW rated power MHHP test system. Experimental results show that, the proposed method provides the continuous excitation current, and the operation of the synchronous generator is uninterrupted. The proposed method is also practical and easily implemented for MHPP systems.