The contamination and environmental risk assessment of the toxic elements in sediments from the middle-downstream (Zhuzhou-Changsha section) of the Xiangjiang River in Hunan Province of China were studied. The results...The contamination and environmental risk assessment of the toxic elements in sediments from the middle-downstream (Zhuzhou-Changsha section) of the Xiangjiang River in Hunan Province of China were studied. The results show that As, Cd, Pb and Zn are major contaminants in sediments, and average concentrations of these elements significantly exceed both the Control Standards for Pollutants in Sludge of China (GB4284-84) for agricultural use in acidic soils and the effect range median (ERM) values. The average concentrations of As, Cd and Pb in the river water slightly exceed the limit of Surface Water Environment Quality Standard (GB3838-2002). The concentrations of As and Cr in depth profiles extensively change, but slight changes are observed in Pb and Zn. Cd and Zn in most sediment samples can easily enter the food-chain and bring possible ecotoxicological risk to organisms living in sediments according to the risk assessment code.展开更多
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen...Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.展开更多
基金Project (20507022) supported by the National Natural Science Foundation of ChinaProject (EREH050303) supported by the Foundation of Ministry of Education Key Laboratory of Environmental Remediation and Ecosystem Health
文摘The contamination and environmental risk assessment of the toxic elements in sediments from the middle-downstream (Zhuzhou-Changsha section) of the Xiangjiang River in Hunan Province of China were studied. The results show that As, Cd, Pb and Zn are major contaminants in sediments, and average concentrations of these elements significantly exceed both the Control Standards for Pollutants in Sludge of China (GB4284-84) for agricultural use in acidic soils and the effect range median (ERM) values. The average concentrations of As, Cd and Pb in the river water slightly exceed the limit of Surface Water Environment Quality Standard (GB3838-2002). The concentrations of As and Cr in depth profiles extensively change, but slight changes are observed in Pb and Zn. Cd and Zn in most sediment samples can easily enter the food-chain and bring possible ecotoxicological risk to organisms living in sediments according to the risk assessment code.
基金Project(2011B061200043)supported by the Guangdong Provincial Department of Science and Technology,China
文摘Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.