Hydrodynamic cavitaion venturi tube technique is used for pico and nano bubble generations in coal column flotation. In order to determine the optimal design of hydrodynamic cavitation venture tube for pico and nano b...Hydrodynamic cavitaion venturi tube technique is used for pico and nano bubble generations in coal column flotation. In order to determine the optimal design of hydrodynamic cavitation venture tube for pico and nano bubble generation, a four-factor three-level Central Composite Design of Experimental was conducted for investigating four important design parameters of cavitation venturi tube governing the median size and the volume of pico and nano bubbles. The test results showed that maximum volume of pico and nano bubbles, 65–75%, and minimum mean pico and nano bubble size,150–240 nm, were achieved at the medium ratio of the diameter of outlet of the venturi-tube and diameter of throat(3–4), medium outlet angle(11–13°), high inlet angle(26–27°) and high ratio of the length of the throat and the diameter of throat(2.3–3). Study the effects of the producing pico and nano bubbles on fine coal flotation was performed in a 5 cm diameter 260 cm height flotation column. The optimal percentage of pico and nano bubbles was about 70%, which produced maximum combustible material recovery of 86% with clean coal ash content of 11.7%.展开更多
Total site heat integration(TSHI) provides more opportunities for energy saving in industry clusters. Some design methods including direct integration using process streams and indirect integration using intermediate-...Total site heat integration(TSHI) provides more opportunities for energy saving in industry clusters. Some design methods including direct integration using process streams and indirect integration using intermediate-fluid circuits, i.e., steam, dowtherms and hot water, have been proposed during last few decades. Indirect heat integration is preferred when the heat sources and sinks are separated in independent plants with rather long distance. This improves energy efficiency by adaption of intermediate fluid circle which acts as a utility provider for plants in a symbiotic network. However, there are some significant factors ignored in conventional TSHI, i.e. the investment of pipeline, cost of pumping and heat loss. These factors simultaneously determine the possibility and performance of heat integration. This work presents a new methodology for indirect heat integration in low temperature range using hot water circuit as intermediate-fluid medium. The new methodology enables the targeting of indirect heat integration across plants considering the factors mentioned earlier. An MINLP model with economic objective is established and solved. The optimization results give the mass flow rate of intermediate-fluid, diameter of pipeline, the temperature of the circuits and the matches of heat exchanger networks(HENS) automatically. Finally, the application of this proposed methodology is illustrated with a case study.展开更多
In this companion paper, flow patterns in the upstream and downstream tubes of a sudden-expansion cross-section (SECS) in a vertical straight pipe were presented. The effect of SECS on flow patterns upstream and down...In this companion paper, flow patterns in the upstream and downstream tubes of a sudden-expansion cross-section (SECS) in a vertical straight pipe were presented. The effect of SECS on flow patterns upstream and downstream was analyzed by comparing with flow patterns in uniform cross-section vertical tubes. It is found the effect is great. There exist great instabilities of two-phase flow in the neighboring areas of the SECS both downstream and upstream.展开更多
基金West Virginia State Coal and Energy Research Bureau(WVCERB)the Department of Mining Engineering,West Virginia University
文摘Hydrodynamic cavitaion venturi tube technique is used for pico and nano bubble generations in coal column flotation. In order to determine the optimal design of hydrodynamic cavitation venture tube for pico and nano bubble generation, a four-factor three-level Central Composite Design of Experimental was conducted for investigating four important design parameters of cavitation venturi tube governing the median size and the volume of pico and nano bubbles. The test results showed that maximum volume of pico and nano bubbles, 65–75%, and minimum mean pico and nano bubble size,150–240 nm, were achieved at the medium ratio of the diameter of outlet of the venturi-tube and diameter of throat(3–4), medium outlet angle(11–13°), high inlet angle(26–27°) and high ratio of the length of the throat and the diameter of throat(2.3–3). Study the effects of the producing pico and nano bubbles on fine coal flotation was performed in a 5 cm diameter 260 cm height flotation column. The optimal percentage of pico and nano bubbles was about 70%, which produced maximum combustible material recovery of 86% with clean coal ash content of 11.7%.
基金Supported by the National Basic Research Program of China(2012CB720500)the National Natural Science Foundation of China(21476256)
文摘Total site heat integration(TSHI) provides more opportunities for energy saving in industry clusters. Some design methods including direct integration using process streams and indirect integration using intermediate-fluid circuits, i.e., steam, dowtherms and hot water, have been proposed during last few decades. Indirect heat integration is preferred when the heat sources and sinks are separated in independent plants with rather long distance. This improves energy efficiency by adaption of intermediate fluid circle which acts as a utility provider for plants in a symbiotic network. However, there are some significant factors ignored in conventional TSHI, i.e. the investment of pipeline, cost of pumping and heat loss. These factors simultaneously determine the possibility and performance of heat integration. This work presents a new methodology for indirect heat integration in low temperature range using hot water circuit as intermediate-fluid medium. The new methodology enables the targeting of indirect heat integration across plants considering the factors mentioned earlier. An MINLP model with economic objective is established and solved. The optimization results give the mass flow rate of intermediate-fluid, diameter of pipeline, the temperature of the circuits and the matches of heat exchanger networks(HENS) automatically. Finally, the application of this proposed methodology is illustrated with a case study.
基金the National Natural Science Foundation of China (No. 59236130).
文摘In this companion paper, flow patterns in the upstream and downstream tubes of a sudden-expansion cross-section (SECS) in a vertical straight pipe were presented. The effect of SECS on flow patterns upstream and downstream was analyzed by comparing with flow patterns in uniform cross-section vertical tubes. It is found the effect is great. There exist great instabilities of two-phase flow in the neighboring areas of the SECS both downstream and upstream.