The effect of electrolyte on settling behavior of kaolinite was studied. Effects of hard water on selective flocculation of diasporic bauxite was tested and the measures were taken to eliminate the effects of Ca2+ an...The effect of electrolyte on settling behavior of kaolinite was studied. Effects of hard water on selective flocculation of diasporic bauxite was tested and the measures were taken to eliminate the effects of Ca2+ and Mg2+ in hard water. The results indicated that, not only the concentration of electrolyte ions but also the ionic valence of the electrolyte ions affects the settling behavior of kaolinite; hard water significantly affects its selective flocculation owing to Ca2+ and Mg2+; general dispersants could not eliminate the effects of Ca2+ and Mg2+. Self-made softening agent in our lab could weaken or eliminate the effects of hard water on flocculation processes. The results of molecular dynamics simulation show that softening agent molecules could restrict Ca2+ and prevent them from playing their roles, so as to eliminate the effects. The continuous pilot experiment results of bauxite flocculation were even better than those obtained in laboratory.展开更多
Chitosan derived from crab shells, was used to prepare the graft polymer in aqueous solution with acrylamide (AM) and methacrylatoethyl trimethyl ammonium chloride (DMC) as raw materials and ceric ammonium nitrate...Chitosan derived from crab shells, was used to prepare the graft polymer in aqueous solution with acrylamide (AM) and methacrylatoethyl trimethyl ammonium chloride (DMC) as raw materials and ceric ammonium nitrate (CAN) as initiator. The flocculation ability of the resulting polymer (PCAD) was studied in waste water treatment experiments. Its properties were determined on the basis of the transmittance of waste water after flocculation. The effects of ehitosan and DMC content on PCAD's flocculation ability were studied. Floeculation experiments were also undertaken under various pH conditions. According to the experimental data, the flocculation ability could be improved when chitosan content decreased in the raw material, but the monomer conversion would decrease obviously. When the ehitosan's content was more than 65%, AM and DMC groups were less on each chitosan molecule. So PCAD's flocculation ability was poor. Similarly, high content of DMC would result in low monomer conversion and high flocculation ability. PCAD molecules with more DMC group had more positive charges. It was favorable to flocculation. However, monomer conversion would decrease with the increase of DMC content. The suitable conditions were that chitosan and DMC contents were 65% and 15-20%, respectively. The experiment data showed that PCAD had good flocculation ability under weak acidic condition. Its ability would be weakened by strong acidic or alkaline condition. The flocculation efficiency was the best at pH of 5.5 when PCAD's dosage was 8mg-Lk Compared with cationic polymer (the copolymer of AM and DMC, PAD), PCAD showed better flocculation ability under acid and neutral conditions, but worse ability under alkaline condition.展开更多
Jar tests were conducted to investigate the performance of enhanced primary treatment processes for low-concentra-tion municipal wastewater from South China by using composite flocculant combined with bio-flocculants ...Jar tests were conducted to investigate the performance of enhanced primary treatment processes for low-concentra-tion municipal wastewater from South China by using composite flocculant combined with bio-flocculants Pullulan and poly-aluminum-chloride (PAC). The optimum dosage for composite flocculant and conditions for flocculation were determined. The experimental results indicated that composite flocculant had high efficiency for removing over 95% of turbidity, over 58% of CODCr (chemical oxygen demand determined with potassium dichromate), over 91% of TP (total phosphate), and over 15% of NH3-N. Moreover, it could improve sludge settling and dehydration properties, and decrease the treatment cost.展开更多
In order to remove the low turbidity present in surface water, a novel metal-polysilicate coagulant was used to treat the raw water taken from Tanjiang River in Guangdong Province. This study on the effects of Al/Fe ...In order to remove the low turbidity present in surface water, a novel metal-polysilicate coagulant was used to treat the raw water taken from Tanjiang River in Guangdong Province. This study on the effects of Al/Fe molar ratio on the performance of a complex compound formed by polysilicic acid, aluminium and ferric salt (PAFS) showed that PAFS with Al/Fe ratio of 10:3 seemed to have the best coagulation performance in removing turbidity and color. Experimental results showed that under the conditions of polymerization time of 15 d, sedimentation time of 12 min, and pH of 6?8, PAFS with Al/Fe molar ratio of 10:3 had the best coagulation efficiency and lowest residual Al concentration. The turbid- ity decreased from 23.8 NTU to 3.23 NTU and the residual Al concentration was only 0.165 mg/L in the product water. It could be speculated that colloidal impurities and particulate Al were removed by adsorption bridging and electrical neu- tralization of long chain inorganic polymer coagulants.展开更多
基金Project (2005CB623701) supported by the National Basic Research Program of China
文摘The effect of electrolyte on settling behavior of kaolinite was studied. Effects of hard water on selective flocculation of diasporic bauxite was tested and the measures were taken to eliminate the effects of Ca2+ and Mg2+ in hard water. The results indicated that, not only the concentration of electrolyte ions but also the ionic valence of the electrolyte ions affects the settling behavior of kaolinite; hard water significantly affects its selective flocculation owing to Ca2+ and Mg2+; general dispersants could not eliminate the effects of Ca2+ and Mg2+. Self-made softening agent in our lab could weaken or eliminate the effects of hard water on flocculation processes. The results of molecular dynamics simulation show that softening agent molecules could restrict Ca2+ and prevent them from playing their roles, so as to eliminate the effects. The continuous pilot experiment results of bauxite flocculation were even better than those obtained in laboratory.
基金supported by Young Scientist Foundation (2008BS09001) from the Department of Science and Technology of Shandong Province
文摘Chitosan derived from crab shells, was used to prepare the graft polymer in aqueous solution with acrylamide (AM) and methacrylatoethyl trimethyl ammonium chloride (DMC) as raw materials and ceric ammonium nitrate (CAN) as initiator. The flocculation ability of the resulting polymer (PCAD) was studied in waste water treatment experiments. Its properties were determined on the basis of the transmittance of waste water after flocculation. The effects of ehitosan and DMC content on PCAD's flocculation ability were studied. Floeculation experiments were also undertaken under various pH conditions. According to the experimental data, the flocculation ability could be improved when chitosan content decreased in the raw material, but the monomer conversion would decrease obviously. When the ehitosan's content was more than 65%, AM and DMC groups were less on each chitosan molecule. So PCAD's flocculation ability was poor. Similarly, high content of DMC would result in low monomer conversion and high flocculation ability. PCAD molecules with more DMC group had more positive charges. It was favorable to flocculation. However, monomer conversion would decrease with the increase of DMC content. The suitable conditions were that chitosan and DMC contents were 65% and 15-20%, respectively. The experiment data showed that PCAD had good flocculation ability under weak acidic condition. Its ability would be weakened by strong acidic or alkaline condition. The flocculation efficiency was the best at pH of 5.5 when PCAD's dosage was 8mg-Lk Compared with cationic polymer (the copolymer of AM and DMC, PAD), PCAD showed better flocculation ability under acid and neutral conditions, but worse ability under alkaline condition.
基金Project (No. 2005AA601010) supported by the Hi-Tech Research and Development Program (863) of China
文摘Jar tests were conducted to investigate the performance of enhanced primary treatment processes for low-concentra-tion municipal wastewater from South China by using composite flocculant combined with bio-flocculants Pullulan and poly-aluminum-chloride (PAC). The optimum dosage for composite flocculant and conditions for flocculation were determined. The experimental results indicated that composite flocculant had high efficiency for removing over 95% of turbidity, over 58% of CODCr (chemical oxygen demand determined with potassium dichromate), over 91% of TP (total phosphate), and over 15% of NH3-N. Moreover, it could improve sludge settling and dehydration properties, and decrease the treatment cost.
基金Project (No. E9825) supported by the Natural Science Foundation of Heilongjiang Province,China
文摘In order to remove the low turbidity present in surface water, a novel metal-polysilicate coagulant was used to treat the raw water taken from Tanjiang River in Guangdong Province. This study on the effects of Al/Fe molar ratio on the performance of a complex compound formed by polysilicic acid, aluminium and ferric salt (PAFS) showed that PAFS with Al/Fe ratio of 10:3 seemed to have the best coagulation performance in removing turbidity and color. Experimental results showed that under the conditions of polymerization time of 15 d, sedimentation time of 12 min, and pH of 6?8, PAFS with Al/Fe molar ratio of 10:3 had the best coagulation efficiency and lowest residual Al concentration. The turbid- ity decreased from 23.8 NTU to 3.23 NTU and the residual Al concentration was only 0.165 mg/L in the product water. It could be speculated that colloidal impurities and particulate Al were removed by adsorption bridging and electrical neu- tralization of long chain inorganic polymer coagulants.