The direct drive electro-hydraulic servo system is a new approach hydraulic system. It is much smaller and easier controlled than traditional systems and is a perfect energy saver. This paper will briefly introduce th...The direct drive electro-hydraulic servo system is a new approach hydraulic system. It is much smaller and easier controlled than traditional systems and is a perfect energy saver. This paper will briefly introduce the popular nonlinearities in the electro-hydraulic system and analyse the effect of nonlinearities in direct drive electro-hydraulic position servo system by means of simulation research. Some valuable conclusions are given.展开更多
This paper sets Chaihu Town, Zhongxiang City of Hubei Province as an example, analyzing the ecological and hydrological conditions of Chaihu Town, applying LID (low impact development) mode and putting forward the e...This paper sets Chaihu Town, Zhongxiang City of Hubei Province as an example, analyzing the ecological and hydrological conditions of Chaihu Town, applying LID (low impact development) mode and putting forward the ecological stormwater regulation system planning strategy which adapts to the development of small towns. The main conclusions are as follows: (1) The "three-low" development mode is put forward, which means low impact, low cost and low carbon, using this construction mode to minimize the ecological impact, relying on natural green space and water to achieve the function of rainstorm regulation; (2) Through the analysis and calculation of the local amount of precipitation, this paper scientifically calculates the required area of storage water and green space, taking the roads as trunks, green spaces as stems, water as veins, and building the green infrastructure system; (3) The author has been repairing and integrating the original drainage ditches of the planning area, replacing traditional rain drainage pipes, establishing "two-loop" water network system which aims at the detention and purification of rainwater, maximizing ecological benefit, economic benefit and landscape benefit.展开更多
The thermal engineering research has been executed for the threecircuit heat exchanger of a coiled type, that provides the thermal loads regulation for the heating and hot water supply systems. A processing curve of t...The thermal engineering research has been executed for the threecircuit heat exchanger of a coiled type, that provides the thermal loads regulation for the heating and hot water supply systems. A processing curve of the warmth supply regulation at a combined heating and hot water supply load, was used at that. It is important to know the processes running inside the apparatus for the technical characteristics improvement of the threecircuit heat exchanger of a coiled type. The task solution will allow save the materials consumption for the threecircuit heat exchangers of a coiled type manufacturing in the future.展开更多
The paper presents selected experience of the authors resulting from the optimization tests of double-regulated water turbines. Among the methods for measuring the discharge through the turbine used in such tests, par...The paper presents selected experience of the authors resulting from the optimization tests of double-regulated water turbines. Among the methods for measuring the discharge through the turbine used in such tests, particular attention was paid to index methods allowing to measure the relative discharge through the turbine-the index current meter method and the methods based on measuring the differential pressure between two points properly located at the turbine flow system (i.e., Winter-Kennedy method). These methods contribute to effective reduction of the cost of optimizing the turbine that is extremely important for small hydropower plants regarding installed capacity. The paper presents selected examples of the optimization tests and experiences that arise from these tests.展开更多
文摘The direct drive electro-hydraulic servo system is a new approach hydraulic system. It is much smaller and easier controlled than traditional systems and is a perfect energy saver. This paper will briefly introduce the popular nonlinearities in the electro-hydraulic system and analyse the effect of nonlinearities in direct drive electro-hydraulic position servo system by means of simulation research. Some valuable conclusions are given.
文摘This paper sets Chaihu Town, Zhongxiang City of Hubei Province as an example, analyzing the ecological and hydrological conditions of Chaihu Town, applying LID (low impact development) mode and putting forward the ecological stormwater regulation system planning strategy which adapts to the development of small towns. The main conclusions are as follows: (1) The "three-low" development mode is put forward, which means low impact, low cost and low carbon, using this construction mode to minimize the ecological impact, relying on natural green space and water to achieve the function of rainstorm regulation; (2) Through the analysis and calculation of the local amount of precipitation, this paper scientifically calculates the required area of storage water and green space, taking the roads as trunks, green spaces as stems, water as veins, and building the green infrastructure system; (3) The author has been repairing and integrating the original drainage ditches of the planning area, replacing traditional rain drainage pipes, establishing "two-loop" water network system which aims at the detention and purification of rainwater, maximizing ecological benefit, economic benefit and landscape benefit.
文摘The thermal engineering research has been executed for the threecircuit heat exchanger of a coiled type, that provides the thermal loads regulation for the heating and hot water supply systems. A processing curve of the warmth supply regulation at a combined heating and hot water supply load, was used at that. It is important to know the processes running inside the apparatus for the technical characteristics improvement of the threecircuit heat exchanger of a coiled type. The task solution will allow save the materials consumption for the threecircuit heat exchangers of a coiled type manufacturing in the future.
文摘The paper presents selected experience of the authors resulting from the optimization tests of double-regulated water turbines. Among the methods for measuring the discharge through the turbine used in such tests, particular attention was paid to index methods allowing to measure the relative discharge through the turbine-the index current meter method and the methods based on measuring the differential pressure between two points properly located at the turbine flow system (i.e., Winter-Kennedy method). These methods contribute to effective reduction of the cost of optimizing the turbine that is extremely important for small hydropower plants regarding installed capacity. The paper presents selected examples of the optimization tests and experiences that arise from these tests.