The present study is conducted in the scenario of the tannery waste hazards in Kasur district of Pakistan where the tannery industry is considered as major cause of groundwater quality deterioration, Area focused in t...The present study is conducted in the scenario of the tannery waste hazards in Kasur district of Pakistan where the tannery industry is considered as major cause of groundwater quality deterioration, Area focused in this research constitutes the surroundings of the effluent carrying drains near tannery units. This study includes soil explorations, groundwater monitoring and wastewater analysis in the research area so as to find out the contamination extent of chromium in subsurface. Initial groundwater monitoring exhibited chromium concentrations as high as 90 mg/L in the tannery area. Even groundwater sampling from monitoring wells installed in the adjacent areas of effluent carrying drains, showed concentrations up to 10.4 mg/L. Wastewater analysis of all the drains in the research area has evidenced potential risk of contaminant seepage into soil and groundwater as level of chromium in wastewater samples has reported to be immensely high and varies from 68 mg/L to 2,152 mg/L. However the 30 soil samples collected from two soil bores did not show any significant results as the maximum values obtained for hexavalent chromium for leaching and retained in soil are 0.02 mg/L and 8.1 mg/kg, respectively. These low concentrations of soil samples suggest that the soil contamination may not be a main environmental issue in the areas adjacent to the effluent carrying drains, The research concludes as possibility of direct interference of the tannery wastewater with groundwater through damaged structures and sewers.展开更多
TOR (Tema oil refinery) is the only petroleum refinery in Ghana. To assess the quality of the wastewater, wastewater samples taken from three points of discharge into the treatment plant and the treated effluent wer...TOR (Tema oil refinery) is the only petroleum refinery in Ghana. To assess the quality of the wastewater, wastewater samples taken from three points of discharge into the treatment plant and the treated effluent were analyzed for physico-chemical characteristics. The levels of the pH, temperature, conductivity, COD (Chemical Oxygen Demand), TDS (Total Dissolved Solids), TSS (Total Suspended Solids) and phenol were assessed from January to June, 2011. The results obtained indicate varied levels of contaminants in both the untreated and treated wastewater. The average values of the treated effluent parameters analyzed were 38 ℃, 6,258 μs.cm-1, 314 mg-L-1, 115 mg.L-1, 2,689 mg-L-1 and 1 mg.L-1 for the temperature, conductivity, COD, TDS, TSS and phenol, respectively. The results suggest that both the raw wastewater and the treated effluent did not meet the discharge limit set by Ghana Environmental Protection Agency. Therefore, the treated effluent required additional treatment before it can be discharged into the environment. This suggests that the wastewater treatment plant of TOR is ineffective for the type of wastewater produced.展开更多
文摘The present study is conducted in the scenario of the tannery waste hazards in Kasur district of Pakistan where the tannery industry is considered as major cause of groundwater quality deterioration, Area focused in this research constitutes the surroundings of the effluent carrying drains near tannery units. This study includes soil explorations, groundwater monitoring and wastewater analysis in the research area so as to find out the contamination extent of chromium in subsurface. Initial groundwater monitoring exhibited chromium concentrations as high as 90 mg/L in the tannery area. Even groundwater sampling from monitoring wells installed in the adjacent areas of effluent carrying drains, showed concentrations up to 10.4 mg/L. Wastewater analysis of all the drains in the research area has evidenced potential risk of contaminant seepage into soil and groundwater as level of chromium in wastewater samples has reported to be immensely high and varies from 68 mg/L to 2,152 mg/L. However the 30 soil samples collected from two soil bores did not show any significant results as the maximum values obtained for hexavalent chromium for leaching and retained in soil are 0.02 mg/L and 8.1 mg/kg, respectively. These low concentrations of soil samples suggest that the soil contamination may not be a main environmental issue in the areas adjacent to the effluent carrying drains, The research concludes as possibility of direct interference of the tannery wastewater with groundwater through damaged structures and sewers.
文摘TOR (Tema oil refinery) is the only petroleum refinery in Ghana. To assess the quality of the wastewater, wastewater samples taken from three points of discharge into the treatment plant and the treated effluent were analyzed for physico-chemical characteristics. The levels of the pH, temperature, conductivity, COD (Chemical Oxygen Demand), TDS (Total Dissolved Solids), TSS (Total Suspended Solids) and phenol were assessed from January to June, 2011. The results obtained indicate varied levels of contaminants in both the untreated and treated wastewater. The average values of the treated effluent parameters analyzed were 38 ℃, 6,258 μs.cm-1, 314 mg-L-1, 115 mg.L-1, 2,689 mg-L-1 and 1 mg.L-1 for the temperature, conductivity, COD, TDS, TSS and phenol, respectively. The results suggest that both the raw wastewater and the treated effluent did not meet the discharge limit set by Ghana Environmental Protection Agency. Therefore, the treated effluent required additional treatment before it can be discharged into the environment. This suggests that the wastewater treatment plant of TOR is ineffective for the type of wastewater produced.