Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running...Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...展开更多
To confirm the rheological characteristic of sewage in the research and application of urban sewage source heat pump system, the viscosity of sewage was investigated. The tube-type rheometer was used in this experimen...To confirm the rheological characteristic of sewage in the research and application of urban sewage source heat pump system, the viscosity of sewage was investigated. The tube-type rheometer was used in this experimental study, and the sewage was treated as homogeneous non-Newtonian fluid. In addition, the relational expression between viscosity parameters was developed, and the function of apparent viscosity was obtained. It is concluded that the viscosity characteristic of sewage is influenced largely by complex mixture in sewage, and the sewage has the characteristic of sheared densification fluid.展开更多
基金Supported by National Natural Science Foundation of China (No. 50578048)"Heating, Gas, Ventilation and Air Conditioning" Key Laboratory Open Subject in Beijing (No. KF200710)the Postdoctoral Researcher Science Foundation of China (No. 20090450986)
文摘Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...
基金Sponsored by the National Natural Science Foundation of China (Grant No.50578048)
文摘To confirm the rheological characteristic of sewage in the research and application of urban sewage source heat pump system, the viscosity of sewage was investigated. The tube-type rheometer was used in this experimental study, and the sewage was treated as homogeneous non-Newtonian fluid. In addition, the relational expression between viscosity parameters was developed, and the function of apparent viscosity was obtained. It is concluded that the viscosity characteristic of sewage is influenced largely by complex mixture in sewage, and the sewage has the characteristic of sheared densification fluid.