This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters fuel substitutio...This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.展开更多
With the analysis on regulating system in 200 MW steam turbine, the necessity of appending the fast-opening function to the original system is set forth and a new type of fast-opening mechanism is devised. The mathema...With the analysis on regulating system in 200 MW steam turbine, the necessity of appending the fast-opening function to the original system is set forth and a new type of fast-opening mechanism is devised. The mathematical model of system is built up. With the use of AMESIM software, the displacement curve of the piston, the force curve of the cartridge valve spool, the pressure curve and the flux curve in the regulation process are obtained based on simulation. The performances of three fast-opening systems composed of cartridge valves with different diameters are compared. Based on the analysis on factors that affect the execution time of fast-opening, the dead zone of the fast-opening system is put forward. To overcome the defect, dif- ferent operation modes are adopted for different zones. The result shows that with the increase of the valve diameter, the regulating time in the dead zone significantly exceeds the fast-opening time in the whole journey. Accordingly, the optimization operation tactic in the dead zone and the qualification conditions are brought forward. The fast-opening system composed of 32 mm cartridge valves is taken as an example with use of the tactic. The simulation result shows that the maximum regulating time is shortened by 509 ms.展开更多
In this paper the effects of the condenser design parameters(such as turbine inlet condition.turbine power and condenser pressure) on heat transfer area,cooling water flow-rate.condenser cost and specific energy gener...In this paper the effects of the condenser design parameters(such as turbine inlet condition.turbine power and condenser pressure) on heat transfer area,cooling water flow-rate.condenser cost and specific energy generation cost are studied for surface type condenser.The results are given in the text and also shown as diagrams.展开更多
Experimental investigations of non-equilibrium spontaneous condensation in transonic steam flow were carded out in linear blade cascade. The linear cascade consists of the stator blades of the last stage of low pressu...Experimental investigations of non-equilibrium spontaneous condensation in transonic steam flow were carded out in linear blade cascade. The linear cascade consists of the stator blades of the last stage of low pressure steam turbine. The applied experimental test section is a part of a small scale steam power plant located at Silesian Uni- versity of Technology in Gliwice. The steam parameters at the test section inlet correspond to the real conditions in low pressure part of 200MWe steam turbine. The losses in the cascade were estimated using measured static pressure and temperature behind the cascade and the total parameters at inlet. The static pressure measurements on the blade surface as well as the Schlieren pictures were used to assess the flow field in linear cascade of steam turbine stator blades.展开更多
基金Foundation item: Supported by the National Special Fund for Agro-scientific Research in the Public Interest (No.201003024), and the National Natural Science Foundation of China (No.51409042 No. 51209034).
文摘This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.
基金Project (No. NCET-04-0545) supported by the "New Century Elitist Supporting Plan" Fund Project of Education Ministry of China
文摘With the analysis on regulating system in 200 MW steam turbine, the necessity of appending the fast-opening function to the original system is set forth and a new type of fast-opening mechanism is devised. The mathematical model of system is built up. With the use of AMESIM software, the displacement curve of the piston, the force curve of the cartridge valve spool, the pressure curve and the flux curve in the regulation process are obtained based on simulation. The performances of three fast-opening systems composed of cartridge valves with different diameters are compared. Based on the analysis on factors that affect the execution time of fast-opening, the dead zone of the fast-opening system is put forward. To overcome the defect, dif- ferent operation modes are adopted for different zones. The result shows that with the increase of the valve diameter, the regulating time in the dead zone significantly exceeds the fast-opening time in the whole journey. Accordingly, the optimization operation tactic in the dead zone and the qualification conditions are brought forward. The fast-opening system composed of 32 mm cartridge valves is taken as an example with use of the tactic. The simulation result shows that the maximum regulating time is shortened by 509 ms.
文摘In this paper the effects of the condenser design parameters(such as turbine inlet condition.turbine power and condenser pressure) on heat transfer area,cooling water flow-rate.condenser cost and specific energy generation cost are studied for surface type condenser.The results are given in the text and also shown as diagrams.
基金supported by the National Science Centre funds within the project with nr.2011/03/B/ST8/06425
文摘Experimental investigations of non-equilibrium spontaneous condensation in transonic steam flow were carded out in linear blade cascade. The linear cascade consists of the stator blades of the last stage of low pressure steam turbine. The applied experimental test section is a part of a small scale steam power plant located at Silesian Uni- versity of Technology in Gliwice. The steam parameters at the test section inlet correspond to the real conditions in low pressure part of 200MWe steam turbine. The losses in the cascade were estimated using measured static pressure and temperature behind the cascade and the total parameters at inlet. The static pressure measurements on the blade surface as well as the Schlieren pictures were used to assess the flow field in linear cascade of steam turbine stator blades.