In this paper, through two case studies, evaporation systems are considered in the context of overall process, and then are optimized to obtain energy-saving effect. The possible evaporation schemes are given when int...In this paper, through two case studies, evaporation systems are considered in the context of overall process, and then are optimized to obtain energy-saving effect. The possible evaporation schemes are given when integrated with the background process and how to optimize the evaporator is shown. From the case studies, it can be seen that sometimes incomplete integration and heat pump evaporation are better than complete integration so should be considered as candidate retrofit schemes.展开更多
文摘In this paper, through two case studies, evaporation systems are considered in the context of overall process, and then are optimized to obtain energy-saving effect. The possible evaporation schemes are given when integrated with the background process and how to optimize the evaporator is shown. From the case studies, it can be seen that sometimes incomplete integration and heat pump evaporation are better than complete integration so should be considered as candidate retrofit schemes.