期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
容积式液压缸带压精密测定液压部件微泄漏量
1
作者 王继昆 张汝贵 秦振山 《包头职业技术学院学报》 2005年第4期7-9,共3页
带压精密测定液压零部件产品微小泄漏量,一直是困扰液压产品生产行业的难题。本文阐述了用容积式液压缸精密测定液压部件产品微泄漏的原理及采取的主要技术措施。
关键词 液压试验台 容积式液压缸 泄漏测量
下载PDF
高低齿迷宫密封泄漏量实验及计算分析 被引量:10
2
作者 周国宇 王旭东 +1 位作者 林智荣 袁新 《工程热物理学报》 EI CAS CSCD 北大核心 2015年第9期1889-1893,共5页
本文通过数值计算模拟了高低齿型迷宫密封的内部流动结构,对比了不同压比和转速下密封性能的变化,同时通过实验验证了模拟结果。实验和计算结果表明,密封的泄漏量随压比的升高而变大,并在一定压比范围具有较好的线性相关性。当转子转速... 本文通过数值计算模拟了高低齿型迷宫密封的内部流动结构,对比了不同压比和转速下密封性能的变化,同时通过实验验证了模拟结果。实验和计算结果表明,密封的泄漏量随压比的升高而变大,并在一定压比范围具有较好的线性相关性。当转子转速比较低时,转动对泄漏量影响不明显;当转速超过某个临界值的时候,泄漏量会随转速的增加而减少。这个临界值的大小与密封的结构、压比等因素有关。通过对密封内部流场结构的分析,提出了初步的优化方案,其中的核心思想是提高间隙节流的强度和动能耗散的速度。 展开更多
关键词 高低齿迷宫密封 内部流动结构 泄漏量测量 优化结构
原文传递
Comparison of two methods for assessing leakage radiation dose around the head of the medical linear accelerators 被引量:1
3
作者 Ehab M. Attalla 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第9期435-438,共4页
Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakag... Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakage radiation around the head of the linear accelerators.Methods:Measurements were performed using a 30 cm3ion chamber;the gantry at 0°,the X-ray head at 0°,the field size at between the central axis and a plane surface at a FSD of 100 as a reference,a series of concentric circles having radii of 50,75,and 100 cm with their common centre at the reference point.The absorbed dose was measured at the reference point,and this would be used as the reference dose.With the diaphragm closed,the measurements were taken along the circumference of the three circles and at 45°intervals.Results:Leakage radiations while the treatment head was in the vertical position varied between 0.016%–0.04%.With the head lying horizontally,leakage radiation was the same order magnitude and varied between 0.02%–0.07%.In the second method,the verification was accomplished by closing the collimator jaws and covering the head of the treatment unit with the ready pack films.The films were marked to permit the determination of their positions on the machine after exposed and processed.With the diaphragm closed,and the ready packs films around the linear accelerator the beam turned on for 2500 cGy(2500 MU).The optical density of these films was measured and compared with this of the reference dose.Leakage radiation varied according to the film positions and the magnitude of leakage was between 0.005%–0.075%.Conclusion:The differences between the values of the leakage radiation levels observed at different measurement points do not only reflect differences in the effective shielding thickness of the head wall,but are also related to differences in the distances between the target and the measurement points.The experimental errors involved in dosimetric measurement also contribute to such differences. 展开更多
关键词 leakage radiation acceptance testing linear accelerator ion chamber ready packs film
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部