One of the key problems in the use of underground gas storage is frequent leakage. It can lead to the actual gas storage amount being less than that accounted for. Combining numerical simulation and parameter auto fit...One of the key problems in the use of underground gas storage is frequent leakage. It can lead to the actual gas storage amount being less than that accounted for. Combining numerical simulation and parameter auto fit, this paper ascertains the dynamic variation of the pressure in the storage reservoir, adjusts the actual injecting and producing gas to fit the accounted pressure with the tested pressure, obtains the gas leakage of the storage, and then determines the difference between accounted amount and leakage amount. The result is the actual reserves of the storage. The simulation result shows that the method presented can provide a theoretic foundation for estimating the leakage amount, thereby ensuring the actual reserves, searching the leakage route, and reducing leakage by adjusting the storage method.展开更多
This paper addresses the effect of leakage on the natural frequencies of a large amplitude vibrating panel backed by a cavity, which has not been considered in many other related studies. The structural-acoustic gover...This paper addresses the effect of leakage on the natural frequencies of a large amplitude vibrating panel backed by a cavity, which has not been considered in many other related studies. The structural-acoustic governing equations are employed to study this nonlinear problem. An elliptical integral method, which was recently developed for the nonlinear panel cavity problem, is introduced here to solve for the structural-acoustics responses. The present results agree reasonably well with those obtained from the classical harmonic balance method. Modal convergences of the nonlinear solutions are performed to verify the proposed method. The effects of vibration amplitude and leakage size are studied and discussed. It is found that (1) the edge leakages in a panel cavity system significantly affect the natural frequency properties, and (2) the edge leakages induce a low frequency acoustic resonance.展开更多
文摘One of the key problems in the use of underground gas storage is frequent leakage. It can lead to the actual gas storage amount being less than that accounted for. Combining numerical simulation and parameter auto fit, this paper ascertains the dynamic variation of the pressure in the storage reservoir, adjusts the actual injecting and producing gas to fit the accounted pressure with the tested pressure, obtains the gas leakage of the storage, and then determines the difference between accounted amount and leakage amount. The result is the actual reserves of the storage. The simulation result shows that the method presented can provide a theoretic foundation for estimating the leakage amount, thereby ensuring the actual reserves, searching the leakage route, and reducing leakage by adjusting the storage method.
基金Project supported by the City USRG Grant(No.7004701),China
文摘This paper addresses the effect of leakage on the natural frequencies of a large amplitude vibrating panel backed by a cavity, which has not been considered in many other related studies. The structural-acoustic governing equations are employed to study this nonlinear problem. An elliptical integral method, which was recently developed for the nonlinear panel cavity problem, is introduced here to solve for the structural-acoustics responses. The present results agree reasonably well with those obtained from the classical harmonic balance method. Modal convergences of the nonlinear solutions are performed to verify the proposed method. The effects of vibration amplitude and leakage size are studied and discussed. It is found that (1) the edge leakages in a panel cavity system significantly affect the natural frequency properties, and (2) the edge leakages induce a low frequency acoustic resonance.