The determination method of 10-hydroxycamptothecin in Camptotheca acuminata fruits by high-performance liquid chromatogram (HPLC) was studied. The HPLC analysis was performed on a HIQ sil C18(4.6×250 mm) column w...The determination method of 10-hydroxycamptothecin in Camptotheca acuminata fruits by high-performance liquid chromatogram (HPLC) was studied. The HPLC analysis was performed on a HIQ sil C18(4.6×250 mm) column with mobile phase of acetonitrilewater (3:7, V:V), flow rate 1 mLmin-1 and UV detective wavelength 266 nm. Extracting 10-hydroxycamptothecin by ultrasonic method from fruits of C. acuminata to prepare samples for analysis was systematically discussed. The optimal extraction condition was carried out by 60% alcohol solution at 60℃ for 50 minutes.展开更多
An ion mobility spectrometer equipped with a laser ionization source is used for the sensitive detection of benzene.Mobility spectra of the benzene are presented.We also discussed the mobility spectra at various conce...An ion mobility spectrometer equipped with a laser ionization source is used for the sensitive detection of benzene.Mobility spectra of the benzene are presented.We also discussed the mobility spectra at various concentrations and drift voltages.Detection limits are determined to be in the upper ppb_v range.In the end,the advantages and possibilities of this technique are briefly discussed.展开更多
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with...The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%.展开更多
Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their d...Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+).展开更多
基金This paper was supported by National Natural Science Foundation of China (No. 30070086).
文摘The determination method of 10-hydroxycamptothecin in Camptotheca acuminata fruits by high-performance liquid chromatogram (HPLC) was studied. The HPLC analysis was performed on a HIQ sil C18(4.6×250 mm) column with mobile phase of acetonitrilewater (3:7, V:V), flow rate 1 mLmin-1 and UV detective wavelength 266 nm. Extracting 10-hydroxycamptothecin by ultrasonic method from fruits of C. acuminata to prepare samples for analysis was systematically discussed. The optimal extraction condition was carried out by 60% alcohol solution at 60℃ for 50 minutes.
文摘An ion mobility spectrometer equipped with a laser ionization source is used for the sensitive detection of benzene.Mobility spectra of the benzene are presented.We also discussed the mobility spectra at various concentrations and drift voltages.Detection limits are determined to be in the upper ppb_v range.In the end,the advantages and possibilities of this technique are briefly discussed.
基金Project (04JJ40016) supported by the Natural Science Foundation of Hunan Province, China
文摘The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%.
基金Projects(61533021,61321003,61273185)supported by the National Natural Science Foundation of ChinaProject(2015CX007)supported by the Innovation-driven Plan in Central South University,ChinaProject(13JJ8003)supported by the Joint Fund of Hunan Provincial Natural Science Foundation of China
文摘Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+).