Various doses of nitrogen ions were implanted into the surface of pure titanium, Ti6Al7Nb and Ti6Al4V, by plasma immersion ion implantation. Torsional fretting wear tests involving flat specimens of no-treated and tre...Various doses of nitrogen ions were implanted into the surface of pure titanium, Ti6Al7Nb and Ti6Al4V, by plasma immersion ion implantation. Torsional fretting wear tests involving flat specimens of no-treated and treated titanium, as well as its alloys, against a ZrO2 ball contact were performed on a torsional fretting wear test rig using a simulated physiological medium of serum solution. The treated surfaces were characterized, and the effect of implantation dose on torsional fretting behavior was discussed in detail. The results showed that the torsional fretting running and damage behavior of titanium and its alloys were strongly dependent on the dose of the implanted nitrogen ions and the angular displacement amplitude. The torsional fretting running boundary moved to smaller angular displacement amplitude, and the central light damage zone decreased, as the ion dose increased. The wear mechanisms of titanium and its alloys were oxidative wear, abrasive wear and delamination, with abrasive wear as the most common mechanism of the ion implantation layers.展开更多
The biological effects during seed germination were investigated after the dry seeds of Stevia rebaudianum Bertoni were implanted with carbon ion beam of 75 keV and 10 14 ions/cm 2. The results showed that the g...The biological effects during seed germination were investigated after the dry seeds of Stevia rebaudianum Bertoni were implanted with carbon ion beam of 75 keV and 10 14 ions/cm 2. The results showed that the germination rate of carbon ion implanted seeds was slightly higher than that of the control, but the survival rate of the treated seedlings, on the contrary, was lower than that of the control (P<0.02), while the height of the treated seedlings was significantly higher than that of the control (P<0.01). On the 4th day after germination, the leaf cell wall in the treated group was thick, some high electron_dense substance deposited in the enlarged plasmodesma; Cell membrane creased with high electron_dense granules deposited on it. The plasma membrane protruded towards cell wall, and the granules shifted via plasmodesma or deposited onto cell wall. These phenomena may be related to the conveyance of implanted ions across cell wall, or be related to the accumulation of callose. In addition, the implantation of carbon ions could increase the lamellae of the chloroplast and cause high development of the chloroplast which sometimes contained two plastid centers in an individual chloroplast. Also, the highly developed cristae, abundant mitochondria and typical crystalloid structure in microbody could be found. All these results indicated that the anabolic and catabolic activities in the seedlings implanted with carbon ions before germination were obviously more active than those in the controls.展开更多
A high speed LIGBT with localized lifetime control by using high dose and low en ergy helium implantation(LC-LIGBT) is proposed.Compared with conventional LIGB Ts,particle irradiation results show that trade-off relat...A high speed LIGBT with localized lifetime control by using high dose and low en ergy helium implantation(LC-LIGBT) is proposed.Compared with conventional LIGB Ts,particle irradiation results show that trade-off relationship between turn- off time and forward voltage drop is improved.At the same time,the forward volta ge drop and turn-off time of such device are researched,when localized lifetime control region place near the p+-n junction,even in p+ anode.The results s how for the first time,helium ions,which stop in the p+ anode,also contribute to the forward voltage drop increasing and turn-off time reducing.展开更多
[Objective] This study was to investigate the effect of N+ ion beam implantation on the survival rate and mutation rate of biocontrol strain Bacillus subtilis. [Method] The factors influencing B. subtilis ion beam im...[Objective] This study was to investigate the effect of N+ ion beam implantation on the survival rate and mutation rate of biocontrol strain Bacillus subtilis. [Method] The factors influencing B. subtilis ion beam implantation, including culture time, dilution concentration, solvent, drying time of mycoderm were optimized. B. subtilis cells were implanted by using ion beam at dose of 2.0×10^14~4.0×10^14 ions/cm2 and the energy of 30 kev. Then the methods of culturing colonies confronting each other on plate and Oxford cup diffusion were used to screening strains. [Result] The optimal parameters were found as follows: culture in liquid for 20-24 h, dilution with sterile water to 106 cells/ml and drying time of 60 min for sample preparation; the optimal N+ ion beam implantation dose of 2.0×10^14~4.0×10^14 ions/cm2 at the energy of 30 kev, the survival rate of 8.43%-26.71% and the mutation rate of 3.50%-5.43%. [Conclusion] This study provided reference for ion beam implantation mutation of B. subtilis.展开更多
A precise theoretical calculation off the pinch of voltage of the box-like ion implantation 4H-SiC MESFETs is investigated with the consideration of the effects of the ion-implanted channel and the depth of MESFETs ch...A precise theoretical calculation off the pinch of voltage of the box-like ion implantation 4H-SiC MESFETs is investigated with the consideration of the effects of the ion-implanted channel and the depth of MESFETs channel.The implant depth profile is simulated using the Monte Carlo simulator TRIM.The effects of parameters such as temperature,acceptor density,and activation rate on channel depth a,pinch off voltage are studied.展开更多
N-wells are created by P+ ion implantation into Si-faced p-type 4H-SiC epilayer. Ti and Ni are deposited in sequence on the surface of the active regions. Ni2Si is identified as the dominant phase by X-ray diffracti...N-wells are created by P+ ion implantation into Si-faced p-type 4H-SiC epilayer. Ti and Ni are deposited in sequence on the surface of the active regions. Ni2Si is identified as the dominant phase by X-ray diffraction (XRD) analysis after metallization annealing. An amorphous C film at the Ni2 Si/SiC interface is confirmed by an X-ray energy-dispersive spectrometer (XEDS). The Ni2Si and amorphous C film are etched away selectively,followed by deposition of new metal films without annealing. Measurement of the current-voltage characteristics shows that the contacts are still ohmic after the Ni2 Si and amorphous C film are replaced by new metal films. The sheet resistance Rsh of the implanted layers decreases from 975 to 438f2/D, because carbon vacancies (Vc) appeared during annealing,which act as donors for electrons in SiC.展开更多
基金Projects(U1530136,51375407)supported by the National Natural Science Foundation of China
文摘Various doses of nitrogen ions were implanted into the surface of pure titanium, Ti6Al7Nb and Ti6Al4V, by plasma immersion ion implantation. Torsional fretting wear tests involving flat specimens of no-treated and treated titanium, as well as its alloys, against a ZrO2 ball contact were performed on a torsional fretting wear test rig using a simulated physiological medium of serum solution. The treated surfaces were characterized, and the effect of implantation dose on torsional fretting behavior was discussed in detail. The results showed that the torsional fretting running and damage behavior of titanium and its alloys were strongly dependent on the dose of the implanted nitrogen ions and the angular displacement amplitude. The torsional fretting running boundary moved to smaller angular displacement amplitude, and the central light damage zone decreased, as the ion dose increased. The wear mechanisms of titanium and its alloys were oxidative wear, abrasive wear and delamination, with abrasive wear as the most common mechanism of the ion implantation layers.
文摘The biological effects during seed germination were investigated after the dry seeds of Stevia rebaudianum Bertoni were implanted with carbon ion beam of 75 keV and 10 14 ions/cm 2. The results showed that the germination rate of carbon ion implanted seeds was slightly higher than that of the control, but the survival rate of the treated seedlings, on the contrary, was lower than that of the control (P<0.02), while the height of the treated seedlings was significantly higher than that of the control (P<0.01). On the 4th day after germination, the leaf cell wall in the treated group was thick, some high electron_dense substance deposited in the enlarged plasmodesma; Cell membrane creased with high electron_dense granules deposited on it. The plasma membrane protruded towards cell wall, and the granules shifted via plasmodesma or deposited onto cell wall. These phenomena may be related to the conveyance of implanted ions across cell wall, or be related to the accumulation of callose. In addition, the implantation of carbon ions could increase the lamellae of the chloroplast and cause high development of the chloroplast which sometimes contained two plastid centers in an individual chloroplast. Also, the highly developed cristae, abundant mitochondria and typical crystalloid structure in microbody could be found. All these results indicated that the anabolic and catabolic activities in the seedlings implanted with carbon ions before germination were obviously more active than those in the controls.
文摘A high speed LIGBT with localized lifetime control by using high dose and low en ergy helium implantation(LC-LIGBT) is proposed.Compared with conventional LIGB Ts,particle irradiation results show that trade-off relationship between turn- off time and forward voltage drop is improved.At the same time,the forward volta ge drop and turn-off time of such device are researched,when localized lifetime control region place near the p+-n junction,even in p+ anode.The results s how for the first time,helium ions,which stop in the p+ anode,also contribute to the forward voltage drop increasing and turn-off time reducing.
基金Supported by the"Bud Plan"Project of Beijing Academy of Science and Technology(No.022)~~
文摘[Objective] This study was to investigate the effect of N+ ion beam implantation on the survival rate and mutation rate of biocontrol strain Bacillus subtilis. [Method] The factors influencing B. subtilis ion beam implantation, including culture time, dilution concentration, solvent, drying time of mycoderm were optimized. B. subtilis cells were implanted by using ion beam at dose of 2.0×10^14~4.0×10^14 ions/cm2 and the energy of 30 kev. Then the methods of culturing colonies confronting each other on plate and Oxford cup diffusion were used to screening strains. [Result] The optimal parameters were found as follows: culture in liquid for 20-24 h, dilution with sterile water to 106 cells/ml and drying time of 60 min for sample preparation; the optimal N+ ion beam implantation dose of 2.0×10^14~4.0×10^14 ions/cm2 at the energy of 30 kev, the survival rate of 8.43%-26.71% and the mutation rate of 3.50%-5.43%. [Conclusion] This study provided reference for ion beam implantation mutation of B. subtilis.
文摘A precise theoretical calculation off the pinch of voltage of the box-like ion implantation 4H-SiC MESFETs is investigated with the consideration of the effects of the ion-implanted channel and the depth of MESFETs channel.The implant depth profile is simulated using the Monte Carlo simulator TRIM.The effects of parameters such as temperature,acceptor density,and activation rate on channel depth a,pinch off voltage are studied.
文摘N-wells are created by P+ ion implantation into Si-faced p-type 4H-SiC epilayer. Ti and Ni are deposited in sequence on the surface of the active regions. Ni2Si is identified as the dominant phase by X-ray diffraction (XRD) analysis after metallization annealing. An amorphous C film at the Ni2 Si/SiC interface is confirmed by an X-ray energy-dispersive spectrometer (XEDS). The Ni2Si and amorphous C film are etched away selectively,followed by deposition of new metal films without annealing. Measurement of the current-voltage characteristics shows that the contacts are still ohmic after the Ni2 Si and amorphous C film are replaced by new metal films. The sheet resistance Rsh of the implanted layers decreases from 975 to 438f2/D, because carbon vacancies (Vc) appeared during annealing,which act as donors for electrons in SiC.