Imaging technologies are utilized to study the brain morphology and the functions of rat models of Parkinson disease (PD). Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) are used to ob...Imaging technologies are utilized to study the brain morphology and the functions of rat models of Parkinson disease (PD). Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) are used to obtain morphological imaging data. Functional imaging data, such as the spectrum and blood flow changes are obtained by proton magnetic resonance spectroscopy (1H-MRS) and CT perfusion (CTP). Results show that PD rat models have no characteristic morphological imaging abnormalities, but exist regional cerebral blood flow (CBF) reductions and spectral changes in the striatum.展开更多
Crystalline Co nanocomposites in the rutile TiO2 were synthesized by 180 keV Co ion beam implantation at temperature of 623 K with the fluence of 4×10^16 cm^-2. The structural and magnetic properties of samples w...Crystalline Co nanocomposites in the rutile TiO2 were synthesized by 180 keV Co ion beam implantation at temperature of 623 K with the fluence of 4×10^16 cm^-2. The structural and magnetic properties of samples with different thermal treatment were characterized by synchrotron radiation X-ray diffraction (SR-XRD), high resolution transmission electron mi- croscopy (HRTEM), Rutherford backscattering/channeling and the superconducting quantum interference device magnetometer. The SR-XRD results reveal the formation of hcp and fce phases of Co clusters, and the SR-XRD and HRTEM show that Co nanocrystals (NCs) have been formed in TiO2 after ion implantation. With increasing of annealing temperature, the transition of hcp to fcc Co is observed, and the Co NCs sizes were increased with increasing post-annealing temperature. At annealing temperature 1073 K, the lattice damaged is significantly removed compared with the virgin sample. The Co NCs forming inside TiO2 are the major contribution of the measured ferromagnetism.展开更多
MULTIPLE sclerosis (MS) is a common inflammatory demyelinating disorder of central nervous system, and the disease burder could be well evaluated by conven-tional magnetic resonance imaging (MRI),1 including T2-we...MULTIPLE sclerosis (MS) is a common inflammatory demyelinating disorder of central nervous system, and the disease burder could be well evaluated by conven-tional magnetic resonance imaging (MRI),1 including T2-weighted, fluid-attenuatd inversion recovery, and postcontrast Tl-weighted sequences. 2 We investigated the perfusion state of MS plaques using brain perfusion imaging in a 12-year-old boy with MS.展开更多
Objective: To investigate the value of MR perfusion imaging in evaluating the curative effect of intervention treatment of hepatic cancer. Methods: 36 patients underwent MR perfusion imaging after intervention treat...Objective: To investigate the value of MR perfusion imaging in evaluating the curative effect of intervention treatment of hepatic cancer. Methods: 36 patients underwent MR perfusion imaging after intervention treatment. The quantization results were differed between carcinoma residue and benign tissue. And the diagnosis accuracy was judged, Results: There was a significant difference in mean MSI between residue tumor after surgery and the benign enhancement area. The timeintension curve of residue tumor was observed to ascend rapidly to reach the peak, whereas that of the enhancement tissue ascended slowly to reach the peak. The sensitivity and specificity of PWl on detection of residuary or recurrent tumor were 0.89 and 0.73 respectively. Conclusion: PWl is a very sensitive imaging technique that can be used to distinguish liver tissue condition after surgery. PWI contributed to early stage diagnosis and dynamic monitoring following HCC surgery.展开更多
Objective To investigate the role of peffusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic fiver. Methods With a 4F catheter, 1% diluted carbon tetrachloride ( 1 ml/kg) was selectively in...Objective To investigate the role of peffusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic fiver. Methods With a 4F catheter, 1% diluted carbon tetrachloride ( 1 ml/kg) was selectively injected into fight or left hepatic artery of 12 dogs fortnightly. The half fiver into which carbon tetrachloride was injected was called as study side (SS), while the other half fiver without carbon tetrachloride injection was called as study control side (SCS). Conventional and peffusion-weighted MRI were performed in every 4 weeks. Via a 4F catheter, 5ml gadolinium diethylentriamine pentaaceti acid (Gd-DTPA) dilution was injected into superior mesenteric artery at the 5th scan. The signal intensity-thne curves of SS, SCS, and portal vein were completed in MR workstation. The maximal relative signal increase ( MRSI), peak time ( tp), and slope of the curves were measured. Results On conventional MR images, no abnormalities of externality and signal intensity were observed in both SS and SCS of fiver at each stage. The mean tp, MP, SI, and slope of intensity-time curves in normal fiver were 10. 56 seconds, 1.01, and 10. 23 arbitrary unit (au)/s, respectively. Three parameters of curves didn't show obvious change in SCS of fiver at every stage. Abnormal perfusion curves occurred in SS of fiver at the 12th week after the 1st injection. The abnormality of perfusion curve in SS was more and more serious as the times of injection increased. The mean tp, IVlRSI, and slope intensity-time curves in SS of fiver were 19.45 seconds, 0. 43, and 3. 60 au/s respectively at the 24th week. Conclusion Perfusion-weighted imaging can potentially provide information about portal peffusion of hepatic parenchyma, and to some degree, reflect the severity of cirrhosis.展开更多
基金Supported by the National Natural Science Foundation of China (30671997)~~
文摘Imaging technologies are utilized to study the brain morphology and the functions of rat models of Parkinson disease (PD). Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) are used to obtain morphological imaging data. Functional imaging data, such as the spectrum and blood flow changes are obtained by proton magnetic resonance spectroscopy (1H-MRS) and CT perfusion (CTP). Results show that PD rat models have no characteristic morphological imaging abnormalities, but exist regional cerebral blood flow (CBF) reductions and spectral changes in the striatum.
基金The work was supported by the National Natural Science Foundation of China (No.10875004 and No.11005005), and National Basic Research Program of China (No.2010CB832904), the 2011 Self-Raised Funds Project of HeBei Science and Technology Bureau (No.11316736), and the 2011 Key Project of the Langfang Teachers College (No.LSZZ201101).
文摘Crystalline Co nanocomposites in the rutile TiO2 were synthesized by 180 keV Co ion beam implantation at temperature of 623 K with the fluence of 4×10^16 cm^-2. The structural and magnetic properties of samples with different thermal treatment were characterized by synchrotron radiation X-ray diffraction (SR-XRD), high resolution transmission electron mi- croscopy (HRTEM), Rutherford backscattering/channeling and the superconducting quantum interference device magnetometer. The SR-XRD results reveal the formation of hcp and fce phases of Co clusters, and the SR-XRD and HRTEM show that Co nanocrystals (NCs) have been formed in TiO2 after ion implantation. With increasing of annealing temperature, the transition of hcp to fcc Co is observed, and the Co NCs sizes were increased with increasing post-annealing temperature. At annealing temperature 1073 K, the lattice damaged is significantly removed compared with the virgin sample. The Co NCs forming inside TiO2 are the major contribution of the measured ferromagnetism.
文摘MULTIPLE sclerosis (MS) is a common inflammatory demyelinating disorder of central nervous system, and the disease burder could be well evaluated by conven-tional magnetic resonance imaging (MRI),1 including T2-weighted, fluid-attenuatd inversion recovery, and postcontrast Tl-weighted sequences. 2 We investigated the perfusion state of MS plaques using brain perfusion imaging in a 12-year-old boy with MS.
文摘Objective: To investigate the value of MR perfusion imaging in evaluating the curative effect of intervention treatment of hepatic cancer. Methods: 36 patients underwent MR perfusion imaging after intervention treatment. The quantization results were differed between carcinoma residue and benign tissue. And the diagnosis accuracy was judged, Results: There was a significant difference in mean MSI between residue tumor after surgery and the benign enhancement area. The timeintension curve of residue tumor was observed to ascend rapidly to reach the peak, whereas that of the enhancement tissue ascended slowly to reach the peak. The sensitivity and specificity of PWl on detection of residuary or recurrent tumor were 0.89 and 0.73 respectively. Conclusion: PWl is a very sensitive imaging technique that can be used to distinguish liver tissue condition after surgery. PWI contributed to early stage diagnosis and dynamic monitoring following HCC surgery.
文摘Objective To investigate the role of peffusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic fiver. Methods With a 4F catheter, 1% diluted carbon tetrachloride ( 1 ml/kg) was selectively injected into fight or left hepatic artery of 12 dogs fortnightly. The half fiver into which carbon tetrachloride was injected was called as study side (SS), while the other half fiver without carbon tetrachloride injection was called as study control side (SCS). Conventional and peffusion-weighted MRI were performed in every 4 weeks. Via a 4F catheter, 5ml gadolinium diethylentriamine pentaaceti acid (Gd-DTPA) dilution was injected into superior mesenteric artery at the 5th scan. The signal intensity-thne curves of SS, SCS, and portal vein were completed in MR workstation. The maximal relative signal increase ( MRSI), peak time ( tp), and slope of the curves were measured. Results On conventional MR images, no abnormalities of externality and signal intensity were observed in both SS and SCS of fiver at each stage. The mean tp, MP, SI, and slope of intensity-time curves in normal fiver were 10. 56 seconds, 1.01, and 10. 23 arbitrary unit (au)/s, respectively. Three parameters of curves didn't show obvious change in SCS of fiver at every stage. Abnormal perfusion curves occurred in SS of fiver at the 12th week after the 1st injection. The abnormality of perfusion curve in SS was more and more serious as the times of injection increased. The mean tp, IVlRSI, and slope intensity-time curves in SS of fiver were 19.45 seconds, 0. 43, and 3. 60 au/s respectively at the 24th week. Conclusion Perfusion-weighted imaging can potentially provide information about portal peffusion of hepatic parenchyma, and to some degree, reflect the severity of cirrhosis.