To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and p...To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season.展开更多
A hybrid optimal algorithm, named the SAA-PA in brief, based on the simulated annealing algorithm (SAA) and the Powell algorithm (PA) is proposed. The proposed algorithm puts the random search strategy of the SAA ...A hybrid optimal algorithm, named the SAA-PA in brief, based on the simulated annealing algorithm (SAA) and the Powell algorithm (PA) is proposed. The proposed algorithm puts the random search strategy of the SAA into the PA, which can prevent optimizing courses from trapping in local optima. The SAA-PA can effectively solve multimodal optimization in the distributed multi-pump Raman amplifier (DMRA). Optimal results show that, under the conditions of the on-off gain of 10 dB, the gain bandwidth of larger than 80 nm and the fiber length of 80 km, the gain ripple of less than 1.25 dB can be designed from the DMRA with only four backward pumps after the optimization of the proposed SAA-PA. Compared with the pure SAA, the SAA-PA can attain a lower gain ripple with the same number of pumps. Also, the relationship between the optimal signal bandwidth and the number of pumps can be simulated numerically with the SAA-PA.展开更多
In this work,we simulated 2D infrared spectroscopy(IR)spectroscopy in both transmission geometry and Brewster-angle reflection geometry.Light dispersion and the leakage of s-polarized light are considered in simulatin...In this work,we simulated 2D infrared spectroscopy(IR)spectroscopy in both transmission geometry and Brewster-angle reflection geometry.Light dispersion and the leakage of s-polarized light are considered in simulating the enhancement factor of the reflection mode.Our simulation shows that the dispersion in reflection will only alter the 2D IR lineshape slightly and can be corrected.Leaking spolarized light due to imperfectness of IR polarizers in the reflection geometry may limit the enhancement factor,but such limit is above what a typical experiment can reach.In the current experiment,the enhancement factor is mainly limited by the precision of incident angle,for which ordinary rotation stages are probably not adequate enough.Moreover,traditional energy ratio of pump and probe pulses,which is 9:1,may not be ideal and could be changed to 2:1 in the reflection geometry.Considering all the above factors,the enhancement on the order of 1000 is possible in the current experiment.Nevertheless,near-Brewster angle reflection will enhance both the signal and the noise caused by the signal itself,therefore this method only works if the noise is unrelated to the signal,particularly if the noise is caused by the fluctuation in the probe.It cannot improve the signal to noise ratio when the dominate noise is from the signal itself.The theoretical results here agree reasonably well with published experiment results and pave way for realizing even higher enhancement at nearer-Brewster angle.展开更多
Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly ...Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly because use working fluids that do not cause ozone depletion and can reduce the global warming emissions.The hybrid heat pump processes combine the conventional vapor-compression and the absorption heat pump cycles.Studies about the simulations and modeling of hybrid heat pumps are few in literature.In this research a mathematical model for single effect absorption and hybrid heat pump is carried out with Chem Cad? 6.0.1.LiBr–H_2O is used as working fluid while electrolytic NRTL and electrolytes latent heat are used as thermodynamic model due to the better results.Binary parameters of activity coef ficients are regressed from experimental vapor pressure data while default constants are used for the solubility expressions.A design of heat pumps is developed and a new modeling of generator is analyzed.The coef ficient of performance of absorption heat pump and hybrid heat pump is equal to 0.7 and 0.83 respectively.For absorption heat pump a sensitivity analysis is carried out to evaluate the effect of temperature and pressure generator,the concentration of Li–Br solution on coef ficient of performance,cooling capacity and working fluid temperature.For hybrid heat pump,the different coef ficients of performance,the primary energy ratio,the generator heat,and the compressor power are analyzed for different values of compressor proportion.Results show that comparing the two systems the hybrid pump allows to save more primary energy,costs and carbon dioxide emissions with respect to absorption heat pump with the increasing of compressor proportion parameter.Future researches should focus on the construction of this heat pumps integrated in chemical processes as a biogas plant or trigeneration systems.展开更多
A single-mode laser noise model driven by quadratic colored pump noise and biased amplitude modulationsignal is proposed.The analytic expression of signal-to-noise ratio is calculated by using a new linearized procedu...A single-mode laser noise model driven by quadratic colored pump noise and biased amplitude modulationsignal is proposed.The analytic expression of signal-to-noise ratio is calculated by using a new linearized procedure.Itis found that there are three different typies of stochastic resonance in the model:the conventional form of stochasticresonance,the stochastic resonance in the broad sense,and the bona fide SR.展开更多
The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature fiel...The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature field and velocity field in the device were obtained. The performance of the liquid-desiccant evaporator was studied as the concentration of the inlet solution varied between 21% and 30% and the pipe wall temperature between 30 and 50 ℃. Results show that the humidification rate and the humidification efficiency increased with the inlet air temperature, the solution flow rate, the solution temperature, and the pipe wall temperature. The humidification rate and humidification efficiency decreased with increasing moisture content in inlet air and the concentration of inlet solution. The humidification rate increased substantially but the humidification efficiency decreased as the inlet air flow rate increased. The error between the simulations and experimental results is acceptable, meaning that our model can provide a theoretical basis for optimizing the performance of a humidifying evaporator.展开更多
Understanding the interaction between a fluid and a solid phase is of fundamental importance to the design of an adsorption process.Because the heat effects associated with adsorption are comparatively large,the as-su...Understanding the interaction between a fluid and a solid phase is of fundamental importance to the design of an adsorption process.Because the heat effects associated with adsorption are comparatively large,the as-sumption of isothermal behavior is a valid approximation only when uptake rates are relatively slow.In this article,we propose to determine when it is needed to choose the isothermal or non-isothermal assumption according to two physical parametersα(ratio convection/capacity) andβ(quantity of energy/capacity) .The proposed problem is solved by a mathematical method in the Laplace domain.Whenα→∞(infinitely high heat transfer coefficient) or β→0(infinitely large heat capacity) ,the limiting case is isothermal.When the diffusion is rapid(α10) the kinetics of sorption is controlled entirely by heat transfer.If the adsorption process is to be used as a heat pump,it shall be represented by an isotherm model withαandβas high as possible.展开更多
基金The National Natural Science Foundation of China(No.50676018)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2008BAJ12B02)
文摘To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season.
基金The Start-Up Research Foundation of Nanjing Uni-versity of Information Science and Technology (No.QD60)
文摘A hybrid optimal algorithm, named the SAA-PA in brief, based on the simulated annealing algorithm (SAA) and the Powell algorithm (PA) is proposed. The proposed algorithm puts the random search strategy of the SAA into the PA, which can prevent optimizing courses from trapping in local optima. The SAA-PA can effectively solve multimodal optimization in the distributed multi-pump Raman amplifier (DMRA). Optimal results show that, under the conditions of the on-off gain of 10 dB, the gain bandwidth of larger than 80 nm and the fiber length of 80 km, the gain ripple of less than 1.25 dB can be designed from the DMRA with only four backward pumps after the optimization of the proposed SAA-PA. Compared with the pure SAA, the SAA-PA can attain a lower gain ripple with the same number of pumps. Also, the relationship between the optimal signal bandwidth and the number of pumps can be simulated numerically with the SAA-PA.
基金supported by the National Natural Science Foundation of China(No.21973102,No.21573243,and No.21327802)。
文摘In this work,we simulated 2D infrared spectroscopy(IR)spectroscopy in both transmission geometry and Brewster-angle reflection geometry.Light dispersion and the leakage of s-polarized light are considered in simulating the enhancement factor of the reflection mode.Our simulation shows that the dispersion in reflection will only alter the 2D IR lineshape slightly and can be corrected.Leaking spolarized light due to imperfectness of IR polarizers in the reflection geometry may limit the enhancement factor,but such limit is above what a typical experiment can reach.In the current experiment,the enhancement factor is mainly limited by the precision of incident angle,for which ordinary rotation stages are probably not adequate enough.Moreover,traditional energy ratio of pump and probe pulses,which is 9:1,may not be ideal and could be changed to 2:1 in the reflection geometry.Considering all the above factors,the enhancement on the order of 1000 is possible in the current experiment.Nevertheless,near-Brewster angle reflection will enhance both the signal and the noise caused by the signal itself,therefore this method only works if the noise is unrelated to the signal,particularly if the noise is caused by the fluctuation in the probe.It cannot improve the signal to noise ratio when the dominate noise is from the signal itself.The theoretical results here agree reasonably well with published experiment results and pave way for realizing even higher enhancement at nearer-Brewster angle.
文摘Recovering waste heat from industrial processes is bene ficial in order to reduce the primary energy demands and heat pumps can be used to this purpose.Absorption heat pumps are energy-saving and environment-friendly because use working fluids that do not cause ozone depletion and can reduce the global warming emissions.The hybrid heat pump processes combine the conventional vapor-compression and the absorption heat pump cycles.Studies about the simulations and modeling of hybrid heat pumps are few in literature.In this research a mathematical model for single effect absorption and hybrid heat pump is carried out with Chem Cad? 6.0.1.LiBr–H_2O is used as working fluid while electrolytic NRTL and electrolytes latent heat are used as thermodynamic model due to the better results.Binary parameters of activity coef ficients are regressed from experimental vapor pressure data while default constants are used for the solubility expressions.A design of heat pumps is developed and a new modeling of generator is analyzed.The coef ficient of performance of absorption heat pump and hybrid heat pump is equal to 0.7 and 0.83 respectively.For absorption heat pump a sensitivity analysis is carried out to evaluate the effect of temperature and pressure generator,the concentration of Li–Br solution on coef ficient of performance,cooling capacity and working fluid temperature.For hybrid heat pump,the different coef ficients of performance,the primary energy ratio,the generator heat,and the compressor power are analyzed for different values of compressor proportion.Results show that comparing the two systems the hybrid pump allows to save more primary energy,costs and carbon dioxide emissions with respect to absorption heat pump with the increasing of compressor proportion parameter.Future researches should focus on the construction of this heat pumps integrated in chemical processes as a biogas plant or trigeneration systems.
基金Supported by National Natural Science Foundation of China under Grant No.10275025
文摘A single-mode laser noise model driven by quadratic colored pump noise and biased amplitude modulationsignal is proposed.The analytic expression of signal-to-noise ratio is calculated by using a new linearized procedure.Itis found that there are three different typies of stochastic resonance in the model:the conventional form of stochasticresonance,the stochastic resonance in the broad sense,and the bona fide SR.
基金Project(2016YFC0700100) supported by the National Key R&D Program of ChinaProject(JDJQ20160103) supported by Promotion of the Connotation Development Quota Project of Colleges and Universities-Outstanding Youth of Architectural University,China
文摘The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature field and velocity field in the device were obtained. The performance of the liquid-desiccant evaporator was studied as the concentration of the inlet solution varied between 21% and 30% and the pipe wall temperature between 30 and 50 ℃. Results show that the humidification rate and the humidification efficiency increased with the inlet air temperature, the solution flow rate, the solution temperature, and the pipe wall temperature. The humidification rate and humidification efficiency decreased with increasing moisture content in inlet air and the concentration of inlet solution. The humidification rate increased substantially but the humidification efficiency decreased as the inlet air flow rate increased. The error between the simulations and experimental results is acceptable, meaning that our model can provide a theoretical basis for optimizing the performance of a humidifying evaporator.
文摘Understanding the interaction between a fluid and a solid phase is of fundamental importance to the design of an adsorption process.Because the heat effects associated with adsorption are comparatively large,the as-sumption of isothermal behavior is a valid approximation only when uptake rates are relatively slow.In this article,we propose to determine when it is needed to choose the isothermal or non-isothermal assumption according to two physical parametersα(ratio convection/capacity) andβ(quantity of energy/capacity) .The proposed problem is solved by a mathematical method in the Laplace domain.Whenα→∞(infinitely high heat transfer coefficient) or β→0(infinitely large heat capacity) ,the limiting case is isothermal.When the diffusion is rapid(α10) the kinetics of sorption is controlled entirely by heat transfer.If the adsorption process is to be used as a heat pump,it shall be represented by an isotherm model withαandβas high as possible.