The design method of small-flow high-head centrifugal-vortex pump was presented. This pump, configured with inducer, complex-centrifugal impeller and open-vortex impeller, was put forward to deliver gas-liquid two-pha...The design method of small-flow high-head centrifugal-vortex pump was presented. This pump, configured with inducer, complex-centrifugal impeller and open-vortex impeller, was put forward to deliver gas-liquid two-phase mixture. An HTB-5/60 type sample pump was developed and tested on a closed-loop test rig. Experimental studies on performance and cavitation tests for gas-liquid two-phase mixture were carried out compared with pure-water experimental results. Also the effect of gas phase on pump was analyzed and discussed. The experimental results show that performance and cavitation characteristics of the sample purnp deteriorates progressively with increasing volume fraction of gas. When the total capacity Qm is between 4.5 m^3·h^-1 and 6 m^3·h^-1 and the gas flow rate qg below 0.66 m^3·h^-1, or qg/Qm is lower than 15%, the characteristic curves are approximately parallel to those in pure water test, but the performance deteriorates sharply until an abrupt flow-cutting at a critical volume fraction of gas. This pump is found suitable for transporting gas-liquid two-phase mixture when working around rated capacity of 5 m^3·h^-1 with qglQm below 15%.展开更多
Free surface vortex control is vital in a pump sump system because the air absorbed by free surface vortex induc- es noise, vibration, and cavitation corrosion on the pumping system. In this study, the change of free ...Free surface vortex control is vital in a pump sump system because the air absorbed by free surface vortex induc- es noise, vibration, and cavitation corrosion on the pumping system. In this study, the change of free surface vor- tex and air absorption in a pump intake has been investigated by the Volume of Fraction (VOF) method with steady multiphase flow model in order to represent the behavior of the free surface vortex exactly. The homoge- neous free surface model is used to apply interactions of air and water. The results show that air intake by the free surface vortex motion can be visualized using the iso-surface of air volume fraction. The vortices make an air column from the free surface to the pump intake. Also, it was found that the flee surface vortex can be controlled by installing curtain walls.展开更多
基金Supported by the National Natural Science Foundation of China (50576088, 20706049) and Zhejiang Provincial Key Science Foundation (2006C21064, 2007C21067).
文摘The design method of small-flow high-head centrifugal-vortex pump was presented. This pump, configured with inducer, complex-centrifugal impeller and open-vortex impeller, was put forward to deliver gas-liquid two-phase mixture. An HTB-5/60 type sample pump was developed and tested on a closed-loop test rig. Experimental studies on performance and cavitation tests for gas-liquid two-phase mixture were carried out compared with pure-water experimental results. Also the effect of gas phase on pump was analyzed and discussed. The experimental results show that performance and cavitation characteristics of the sample purnp deteriorates progressively with increasing volume fraction of gas. When the total capacity Qm is between 4.5 m^3·h^-1 and 6 m^3·h^-1 and the gas flow rate qg below 0.66 m^3·h^-1, or qg/Qm is lower than 15%, the characteristic curves are approximately parallel to those in pure water test, but the performance deteriorates sharply until an abrupt flow-cutting at a critical volume fraction of gas. This pump is found suitable for transporting gas-liquid two-phase mixture when working around rated capacity of 5 m^3·h^-1 with qglQm below 15%.
基金supported by"BK21 Plus project"and"Human Resources Program in Energy Technology"(KETEP)granted financial resource from the Ministry of Trade,Industry&Energy,Republic of Korea.(No.20164010200940)
文摘Free surface vortex control is vital in a pump sump system because the air absorbed by free surface vortex induc- es noise, vibration, and cavitation corrosion on the pumping system. In this study, the change of free surface vor- tex and air absorption in a pump intake has been investigated by the Volume of Fraction (VOF) method with steady multiphase flow model in order to represent the behavior of the free surface vortex exactly. The homoge- neous free surface model is used to apply interactions of air and water. The results show that air intake by the free surface vortex motion can be visualized using the iso-surface of air volume fraction. The vortices make an air column from the free surface to the pump intake. Also, it was found that the flee surface vortex can be controlled by installing curtain walls.