A 3D numerical investigation has been carried out to examine periodic laminar flow and heat transfer characteristics in a circular tube with 45°V-baffles with isothermal wall.The computations are based on the fin...A 3D numerical investigation has been carried out to examine periodic laminar flow and heat transfer characteristics in a circular tube with 45°V-baffles with isothermal wall.The computations are based on the finite volume method(FVM),and the SIMPLE algorithm has been implemented.The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 2000.To generate main longitudinal vortex flows through the tested section,V-baffles with an attack angle of 45°are mounted in tandem and in-line arrangement on the opposite positions of the circular tube.Effects of tube blockage ratio,flow direction on heat transfer and pressure drop in the tube are studied.It is apparent that a pair of longitudinal twisted vortices(P-vortex)created by a V-baffle can induce impingement on a wall of the inter-baffle cavity and lead a drastic increase in heat transfer rate at tube wall.In addition,the larger blockage ratio results in the higher Nusselt number and friction factor values.The computational results show that the optimum thermal enhancement factor is around 3.20 at baffle height of B=0.20 and B=0.25 times of the tube diameter for the V-upstream and V-downstream,respectively.展开更多
The convective heat transfer and friction behaviors of turbulent tube flow through a straight tape with double-sided delta wings(T-W)have been studied experimentally.In the current work,the T-W formed on the tape was ...The convective heat transfer and friction behaviors of turbulent tube flow through a straight tape with double-sided delta wings(T-W)have been studied experimentally.In the current work,the T-W formed on the tape was used as vortex generators for enhancing the heat transfer coefficient by breakdown of thermal boundary layer and by mixing of fluid flow in tubes.The T-W characteristics are(1)T-W with forward/backward-wing arrangement,(2)T-W with alternate axis(T-WA),(3)three wing-width ratios and(4)wing-pitch ratios.The experimental result reveals that for using the T-W,the increases in the mean Nusselt number(Nu)and friction factor are,respectively,up to 165%and 14.8 times of the plain tube and the maximum thermal performance factor is 1.19.It is also obvious that the T-W with forward-wing gives higher heat transfer rate than one with backward-wing around 7%. The present investigation also shows that the heat transfer rate and friction factor obtained from the T-WA is higher than that from the T-W.In addition,the flow pattern and temperature fields in the T-W tube with both backward and forward wings were also examined numerically.展开更多
This research work numerically analyzes 2D,steady state,mixed convective heat transfer for Newtonian fluids in lid driven square enclosure with centered triangular block(blockage—10%or 30%)maintained either at the ...This research work numerically analyzes 2D,steady state,mixed convective heat transfer for Newtonian fluids in lid driven square enclosure with centered triangular block(blockage—10%or 30%)maintained either at the constant wall temperature or constant heat flux thermal conditions.The fluid flow in the enclosure is initiated by top moving wall in+x-direction,while all other walls are stationary.The top and bottom walls are thermally insulated.In particular,the governing field equations are solved for range of governing parameters such as,Reynolds number(1–1000),Prandtl number(1–100),and Grashof number展开更多
基金Supported by the King Mongkut's Institute of Technology Ladkrabang research fund,Thailand(KREF015611)
文摘A 3D numerical investigation has been carried out to examine periodic laminar flow and heat transfer characteristics in a circular tube with 45°V-baffles with isothermal wall.The computations are based on the finite volume method(FVM),and the SIMPLE algorithm has been implemented.The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 2000.To generate main longitudinal vortex flows through the tested section,V-baffles with an attack angle of 45°are mounted in tandem and in-line arrangement on the opposite positions of the circular tube.Effects of tube blockage ratio,flow direction on heat transfer and pressure drop in the tube are studied.It is apparent that a pair of longitudinal twisted vortices(P-vortex)created by a V-baffle can induce impingement on a wall of the inter-baffle cavity and lead a drastic increase in heat transfer rate at tube wall.In addition,the larger blockage ratio results in the higher Nusselt number and friction factor values.The computational results show that the optimum thermal enhancement factor is around 3.20 at baffle height of B=0.20 and B=0.25 times of the tube diameter for the V-upstream and V-downstream,respectively.
基金Supported by the Thailand Research Fund(TRF),Office of Higher Education Commission and Mahanakorn University of Technology
文摘The convective heat transfer and friction behaviors of turbulent tube flow through a straight tape with double-sided delta wings(T-W)have been studied experimentally.In the current work,the T-W formed on the tape was used as vortex generators for enhancing the heat transfer coefficient by breakdown of thermal boundary layer and by mixing of fluid flow in tubes.The T-W characteristics are(1)T-W with forward/backward-wing arrangement,(2)T-W with alternate axis(T-WA),(3)three wing-width ratios and(4)wing-pitch ratios.The experimental result reveals that for using the T-W,the increases in the mean Nusselt number(Nu)and friction factor are,respectively,up to 165%and 14.8 times of the plain tube and the maximum thermal performance factor is 1.19.It is also obvious that the T-W with forward-wing gives higher heat transfer rate than one with backward-wing around 7%. The present investigation also shows that the heat transfer rate and friction factor obtained from the T-WA is higher than that from the T-W.In addition,the flow pattern and temperature fields in the T-W tube with both backward and forward wings were also examined numerically.
文摘This research work numerically analyzes 2D,steady state,mixed convective heat transfer for Newtonian fluids in lid driven square enclosure with centered triangular block(blockage—10%or 30%)maintained either at the constant wall temperature or constant heat flux thermal conditions.The fluid flow in the enclosure is initiated by top moving wall in+x-direction,while all other walls are stationary.The top and bottom walls are thermally insulated.In particular,the governing field equations are solved for range of governing parameters such as,Reynolds number(1–1000),Prandtl number(1–100),and Grashof number