In order to obtain the primary parameters and operating characteristics of a DC motor without directly measuring its torque and rational speed, it is proposed to use a PC and a data acquisition card to acquire both th...In order to obtain the primary parameters and operating characteristics of a DC motor without directly measuring its torque and rational speed, it is proposed to use a PC and a data acquisition card to acquire both the dynamic and static data of armature current to establish the performance of a DC permanent magnet motor. The accuracy and validity of this virtual test system proposed were verified by comparing the measurements made with the system proposed with the measurements made with conventional torque meters. It is concluded from the results of comparison that from the mathematic model established for the DC permant magnet motors, both major parameters and operating characteristics can be directly established for the DC motors without measuring their torques and rotational speed, a perfect on line measurement and test system has been established for the DC permanent magnet motors using the theory of virtual test system. The system proposed features shorter test time, higher efficiency and lower cost.展开更多
A benchmark solution is of great importance in validating algorithms and codes for magnetohydrodynamic(MHD) flows.Hunt and Shercliff's solutions are usually employed as benchmarks for MHD flows in a duct with insu...A benchmark solution is of great importance in validating algorithms and codes for magnetohydrodynamic(MHD) flows.Hunt and Shercliff's solutions are usually employed as benchmarks for MHD flows in a duct with insulated walls or with thin conductive walls,in which wall effects on MHD are represented by the wall conductance ratio.With wall thickness resolved,it is stressed that the solution of Sloan and Smith's and the solution of Butler's can be used to check the error of the thin wall approximation condition used for Hunt's solutions.It is noted that Tao and Ni's solutions can be used as a benchmark for MHD flows in a duct with wall symmetrical or unsymmetrical,thick or thin.When the walls are symmetrical,Tao and Ni's solutions are reduced to Sloan and Smith's solution and Butler's solution,respectively.展开更多
Using data from the Cluster spacecraft from January 2003 to December 2004, we perform a statistical study on some properties of the field-aligned electron(FAE) events and interplanetary magnetic field(IMF) By dependen...Using data from the Cluster spacecraft from January 2003 to December 2004, we perform a statistical study on some properties of the field-aligned electron(FAE) events and interplanetary magnetic field(IMF) By dependence of FAE events with different durations in high-altitude polar regions. A total of 1335 FAE events were observed by the C3 spacecraft. More down-flowing events were observed in the Southern Hemisphere, and more up-flowing events were observed in the Northern Hemisphere. It proves that down-flowing events mainly originate from magnetosphere or solar wind and up-flowing events are mainly derived from ionosphere. Short-lifetime events showed a morning concentration in the magnetic local time distribution, and long-lifetime events were concentrated both before and after noon. For the IMF By dependence of the FAE events, short-lifetime events were much affected by IMF By and resulted in a morning concentration, while the long-lifetime events were almost unaffected by IMF By. With further analysis, we determined that the short-lifetime and long-lifetime events had different sources.展开更多
文摘In order to obtain the primary parameters and operating characteristics of a DC motor without directly measuring its torque and rational speed, it is proposed to use a PC and a data acquisition card to acquire both the dynamic and static data of armature current to establish the performance of a DC permanent magnet motor. The accuracy and validity of this virtual test system proposed were verified by comparing the measurements made with the system proposed with the measurements made with conventional torque meters. It is concluded from the results of comparison that from the mathematic model established for the DC permant magnet motors, both major parameters and operating characteristics can be directly established for the DC motors without measuring their torques and rotational speed, a perfect on line measurement and test system has been established for the DC permanent magnet motors using the theory of virtual test system. The system proposed features shorter test time, higher efficiency and lower cost.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11125212 and 50936066)the National Magnetic Confinement Fusion Science Program of China (Grant No. 2009GB10401)
文摘A benchmark solution is of great importance in validating algorithms and codes for magnetohydrodynamic(MHD) flows.Hunt and Shercliff's solutions are usually employed as benchmarks for MHD flows in a duct with insulated walls or with thin conductive walls,in which wall effects on MHD are represented by the wall conductance ratio.With wall thickness resolved,it is stressed that the solution of Sloan and Smith's and the solution of Butler's can be used to check the error of the thin wall approximation condition used for Hunt's solutions.It is noted that Tao and Ni's solutions can be used as a benchmark for MHD flows in a duct with wall symmetrical or unsymmetrical,thick or thin.When the walls are symmetrical,Tao and Ni's solutions are reduced to Sloan and Smith's solution and Butler's solution,respectively.
基金supported by the National Natural Science Foundation of China(Grant Nos.4127414641474137 and 41374169)the Specialized Research Fund for State Key Laboratory in China
文摘Using data from the Cluster spacecraft from January 2003 to December 2004, we perform a statistical study on some properties of the field-aligned electron(FAE) events and interplanetary magnetic field(IMF) By dependence of FAE events with different durations in high-altitude polar regions. A total of 1335 FAE events were observed by the C3 spacecraft. More down-flowing events were observed in the Southern Hemisphere, and more up-flowing events were observed in the Northern Hemisphere. It proves that down-flowing events mainly originate from magnetosphere or solar wind and up-flowing events are mainly derived from ionosphere. Short-lifetime events showed a morning concentration in the magnetic local time distribution, and long-lifetime events were concentrated both before and after noon. For the IMF By dependence of the FAE events, short-lifetime events were much affected by IMF By and resulted in a morning concentration, while the long-lifetime events were almost unaffected by IMF By. With further analysis, we determined that the short-lifetime and long-lifetime events had different sources.