期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
FreeLink DSLAM
1
《通讯世界》 2004年第4期97-97,共1页
关键词 烽火科技公司 FREELINK DSLAM 体系结构 ADSL接入 流控功能
下载PDF
Dysfunctional Audit Behaviour: The Effects of Employee Performance, Turnover Intentions and Locus of Control
2
作者 Halil Paino Zubaidah Ismail Malcolm Smith 《Journal of Modern Accounting and Auditing》 2011年第4期418-423,共6页
Dy Ov sfunctional audit behaviour (DAB) and staff turnover are associated with decreased audit quality (Public ersight Board, 2000). This study develops and tests a theoretical model that turnover intentions and l... Dy Ov sfunctional audit behaviour (DAB) and staff turnover are associated with decreased audit quality (Public ersight Board, 2000). This study develops and tests a theoretical model that turnover intentions and locus of control as antecedents of attitudes toward DAB survey results from 225 auditors support the theoretical model identifies employee performance, Using a path analysis technique, 展开更多
关键词 dysfunctional audit behaviour (DAB) employee performance turnover intentions locus of control
下载PDF
Systematic Logic Controller Design as Sequential Function Chart Starting from Informal Specifications
3
作者 Sven Lohmann Sebastian Engell 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第1期43-47,共5页
Today's automation industry is driven by the need for an increased productivity, higher flexibility, and higher individuality, and characterized by tailor-made and more complex control solutions. In the processing in... Today's automation industry is driven by the need for an increased productivity, higher flexibility, and higher individuality, and characterized by tailor-made and more complex control solutions. In the processing industry, logic controller design is often a manual, experience-based, and thus an error-prone procedure. Typically, the specifications are given by a set of informal requirements and a technical flowchart and both are used to be directly translated into the control code. This paper proposes a method in which the control program is constructed as a sequential function chart (SFC) by transforming the requirements via clearly defined intermediate formats. For the purpose of analysis, the resulting SFC can be translated algorithmically into timed automata. A rigorous verification can be used to determine whether all specifications are satisfied if a formal model of the plant is available which is then composed with the automata model of the logic controller (LC). 展开更多
关键词 logic controller design systematic approach informal requirements VERIFICATION
下载PDF
The scheme optimization on construction diversion with discharge control feature of upstream operational reservoir
4
作者 Liu Quan Hu Zhigen +2 位作者 Fan Wuyi Ni Jinchu Li Qinjun 《Engineering Sciences》 EI 2012年第4期61-67,82,共8页
There is a discharge control feature of construction diversion system with the upstream operational reservoir. The risk evaluation model of construction diversion is established by taking into consideration the risk f... There is a discharge control feature of construction diversion system with the upstream operational reservoir. The risk evaluation model of construction diversion is established by taking into consideration the risk factors of construction diversion system with discharge control feature as well as their composition. And the risk factors include the upstream operational reservoir discharge control, the interval flood and branch flood and the diversion system itself. And then based on analyzing of the conversion relation between risk index and investment index of diversion scheme, the risk control and conversion principals of diversion system are put forward, and the feasible diversion scheme model is built. At last, the risk and economic evaluation and scheme economic feasibility analysis method of diversion scheme are shown by an example of construction diversion scheme optimization with the discharge control condition of upstream hydropower station. The study is valuable for establishment and optimization of construction diversion scheme with upstream reservoir discharge control. 展开更多
关键词 construction diversion cascade hydropower development risk analysis scheme optimization
下载PDF
上一页 1 下一页 到第