To improve the dust removal performance of the wet electrostatic precipitator(WESP), a flow field optimization scheme was proposed via CFD simulation in different scales. The simplified models of perforated and collec...To improve the dust removal performance of the wet electrostatic precipitator(WESP), a flow field optimization scheme was proposed via CFD simulation in different scales. The simplified models of perforated and collection plates were determined firstly. Then the model parameters for the resistance of perforated and collection plates, obtained by small-scale flow simulation, were validated by medium-scale experiments. Through the comparison of the resistance and velocity distribution between simulation results and experimental data, the simplified model is proved to present the resistance characteristics of perforated and collection plates accurately. Numerical results show that after optimization, both the flow rate and the pressure drop in the upper room of electric field regions are basically equivalent to those of the lower room, and the velocity distribution in flue inlet of WESP becomes more uniform. Through the application in practice, the effectiveness and reliability of the optimization scheme are proved, which can provide valuable reference for further optimization of WESP.展开更多
This paper proposes the financial index of payback period analysis in order to evaluate the economic performance of lighting system. Conventional designs and proposed optimal design using the Energy Conversation Promo...This paper proposes the financial index of payback period analysis in order to evaluate the economic performance of lighting system. Conventional designs and proposed optimal design using the Energy Conversation Promotion Act (No. 2) B.E. 2550 of Ministry of Energy (Section--The Type or Size of Building Standards and Rules and Procedures, Building Design for Energy Conservation, Act B.E. 2552) are compared based on illumination standard for office building in term of energy consumption, return of investment and environmental impact. Firstly, the Type or Size of Building Standards and Rule and Procedures, Building Design for Energy Conservation, Act B.E. 2552 is reviewed and compared with the conventional designs of lighting system for office building. Next, the lifetime energy consumption of fluorescent lamp T5 with electronic ballast, fluorescent lamp T8 with standard ballast and fluorescent lamp T8 with electronic ballast are simulated using DIALux software program in three sizes office buildings. Then, the payback period and CO2 emission of lighting system for selected office building are simulated by various scenarios, which the analytical results show are the optimal lighting system for office building under the present situation. Finally, the optimal design of lighting system for designated office building in Thailand will be discussed with respect to the energy performance with environmental friendly.展开更多
文摘To improve the dust removal performance of the wet electrostatic precipitator(WESP), a flow field optimization scheme was proposed via CFD simulation in different scales. The simplified models of perforated and collection plates were determined firstly. Then the model parameters for the resistance of perforated and collection plates, obtained by small-scale flow simulation, were validated by medium-scale experiments. Through the comparison of the resistance and velocity distribution between simulation results and experimental data, the simplified model is proved to present the resistance characteristics of perforated and collection plates accurately. Numerical results show that after optimization, both the flow rate and the pressure drop in the upper room of electric field regions are basically equivalent to those of the lower room, and the velocity distribution in flue inlet of WESP becomes more uniform. Through the application in practice, the effectiveness and reliability of the optimization scheme are proved, which can provide valuable reference for further optimization of WESP.
文摘This paper proposes the financial index of payback period analysis in order to evaluate the economic performance of lighting system. Conventional designs and proposed optimal design using the Energy Conversation Promotion Act (No. 2) B.E. 2550 of Ministry of Energy (Section--The Type or Size of Building Standards and Rules and Procedures, Building Design for Energy Conservation, Act B.E. 2552) are compared based on illumination standard for office building in term of energy consumption, return of investment and environmental impact. Firstly, the Type or Size of Building Standards and Rule and Procedures, Building Design for Energy Conservation, Act B.E. 2552 is reviewed and compared with the conventional designs of lighting system for office building. Next, the lifetime energy consumption of fluorescent lamp T5 with electronic ballast, fluorescent lamp T8 with standard ballast and fluorescent lamp T8 with electronic ballast are simulated using DIALux software program in three sizes office buildings. Then, the payback period and CO2 emission of lighting system for selected office building are simulated by various scenarios, which the analytical results show are the optimal lighting system for office building under the present situation. Finally, the optimal design of lighting system for designated office building in Thailand will be discussed with respect to the energy performance with environmental friendly.