期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
减速顶压力阀流量—压力特性分析
1
作者 左金池 《郑铁科技》 2009年第1期1-4,10,共5页
通过分析现在铁路编组场使用最多的两种形式的减速顶压力阀流量—压力特性,指出了影响压力阀流量—压力特性的主要因素,为编组场线路的一些特殊区段安装减速顶提供确定开启压力的依据。
关键词 减速顶 流量—压力特性 压力 铁路编组场
原文传递
Structure optimization and flow field simulation of plate type high speed on-off valve 被引量:7
2
作者 WANG Xiao-jing LI Wen-jie +1 位作者 LI Chun-hui PENG Yi-wen 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第5期1557-1571,共15页
There is a relatively complex flow state inside the high speed on-off valve,which often produces low pressure area and oil reflux in the high-speed opening and closing process of the spool,causing cavitation and vorte... There is a relatively complex flow state inside the high speed on-off valve,which often produces low pressure area and oil reflux in the high-speed opening and closing process of the spool,causing cavitation and vortex and other phenomena.These phenomena will affect the stability of the internal flow field of the plate valve and the flow characteristics of the high speed on-off valve.Aiming at the problems of small flow rate and instability of internal flow field,a new spool structure was designed.The flow field models of two-hole and three-hole plate spools with different openings were established,and software ANSYS Workbench was chosen to mesh the model.The standard k−εturbulence model was selected for numerical simulation using FLUENT software.The pressure distribution and velocity distribution under the same pressure and different opening degree were obtained.The structure and parameters of the optimization model were also obtained.The stability analysis of flow field under different pressure was carried out.The results demonstrate that the three-hole spool has a similar flow field change with the two-hole spool,but it does not create a low pressure zone,and the three-hole spool can work stably at 2 MPa or less.This method improves the appearance of low pressure area and oil backflow in the process of high speed opening and closing of spool.The stability of flow field and the flow rate of high speed switch valve are improved.Finally,the products designed in this paper are compared with existing hydraulic valve products.The results show that the three-hole plate type high speed on-off valve designed in this paper maintains the stability of the internal flow field under the condition of 200 Hz and large opening degree,and realizes the increase of flow rate. 展开更多
关键词 high speed on-off valve flow field simulation pressure and flow characteristics
下载PDF
Flow characteristics of variable hydraulic transformer 被引量:2
3
作者 杨冠中 姜继海 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第6期2137-2148,共12页
A new kind of hydraulic transformer, called variable hydraulic transformer(VHT), is proposed to control its load flow rate. The hydraulic transformer evolves from a pressure transducer to a power transducer. The flow ... A new kind of hydraulic transformer, called variable hydraulic transformer(VHT), is proposed to control its load flow rate. The hydraulic transformer evolves from a pressure transducer to a power transducer. The flow characteristics of VHT, such as its instantaneous flow rates, average flow rates, and flow pulsations in the ports, are investigated. Matlab software is used to simulate and calculate. There are five controlled angles of the port plate that can help to define the flow characteristics of VHT. The relationships between the flow characteristics and the structure in VHT are shown. Also, the plus-minus change of the average flow rates and the continuity of the instantaneous flow rates in the ports are presented. The results demonstrate the performance laws of VHT when the controlled angles of the port plate and of the swash plate change. The results also reveal that the special principle of the flow pulsation in the ports and the jump points of the instantaneous curves are the two basic causes of its loud noise, and that the control angles of the port plate and the swash plate and the pressures in the ports are the three key factors of the noise. 展开更多
关键词 hydraulic transformer ENERGY-SAVING instantaneous flow rate average flow rate flow pulsation noise
下载PDF
Flow Fields with Vortex in a Small Semi-open Axial Fan 被引量:12
4
作者 Norimasa. Shiomi Yoichi Kinoue +2 位作者 Ying zi Jin Toshiaki Setoguchi Kenji Kaneko 《Journal of Thermal Science》 SCIE EI CAS CSCD 2009年第4期294-300,共7页
In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of tes... In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC-4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm. 展开更多
关键词 FAN semi-open type VORTEX tip clearance
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部