[Objective] This research aimed to study the pre-treatment conditions of head space so as to establish a HS-GC determination method, which is suitable for China's conditions, for trace volatile organic compounds i...[Objective] This research aimed to study the pre-treatment conditions of head space so as to establish a HS-GC determination method, which is suitable for China's conditions, for trace volatile organic compounds in drinking water. [Method]The preparation method of head space was adopted for the volatile organic compounds in drinking water. [Result] The 20 kinds of volatile organic compounds in drinking water all could be detected simultaneously by using HS-GC-FID method,and they all could be separated well. The HS-GC-FID method could analyze the detected substances qualitatively and quantitatively. In addition, this detection method was characterized by larger linear range of concentration, higher precision, higher detection limit and higher recovery rate. [Conclusion] Under certain conditions, HSGC can reduce the loss of volatile organic compound in drinking water and improve the sensitivity of detection. Moreover, the detection results meet the requirements by quality control.展开更多
A flow-based iodometric extraction method for the determination of selenium sulfide was developed and applied to cosmeceutical products. Iodine which was generated from the reduction of selenium(IV) ions by iodide i...A flow-based iodometric extraction method for the determination of selenium sulfide was developed and applied to cosmeceutical products. Iodine which was generated from the reduction of selenium(IV) ions by iodide ion was on-line extracted using a polypropylene HFM (hollow fiber membrane) liquid extraction technique. The HFM extraction unit was constructed and used to support an organic solvent (hexane) and separate between the organic phase and aqueous phase. The resulting purple extract was carried to a fiber optic spectrophotometric detector for the measurement at 521 nm. Parameters which affected the extraction efficiency, sensitivity and sample throughput such as iodide (selenium molar ratio, extraction time and washing time between the cycles) were investigated and optimized. A linear dynamic range of 80-373 mg.Lt selenium solution was obtained with an extraction time of 60 sec. The total analysis time including washing was about 180 sec which provided a sample throughput of approximately 20 samples'hr1 and excluded the sample pre-treatment. The recoveries for the determination of selenium in the forms of selenium dioxide and selenium sulfide were in the range of 103%-104% with 1%-3% RSD (relative standard deviation). The relative errors of this method which was applied for determination of selenium sulfide levels in an anti-dandruff shampoo and a cosmeceutical bead sample were both less than 2.5%.展开更多
A novel approach, which can handle ambiguous data from weak targets, is proposed within the randomized Hough transform track-before-detect(RHT-TBD) framework. The main idea is that, without the pre-detection and ambig...A novel approach, which can handle ambiguous data from weak targets, is proposed within the randomized Hough transform track-before-detect(RHT-TBD) framework. The main idea is that, without the pre-detection and ambiguity resolution step at each time step, the ambiguous measurements are mapped by the multiple hypothesis ranging(MHR) procedure. In this way, all the information, based on the relativity in time and pulse repetition frequency(PRF) domains, can be gathered among different PRFs and integrated over time via a batch procedure. The final step is to perform the RHT with all the extended measurements, and the ambiguous data is unfolded while the detection decision is confirmed at the end of the processing chain.Unlike classic methods, the new approach resolves the problem of range ambiguity and detects the true track for targets. Finally, its application is illustrated to analyze and compare the performance between the proposed approach and the existing approach. Simulation results exhibit the effectiveness of this approach.展开更多
文摘[Objective] This research aimed to study the pre-treatment conditions of head space so as to establish a HS-GC determination method, which is suitable for China's conditions, for trace volatile organic compounds in drinking water. [Method]The preparation method of head space was adopted for the volatile organic compounds in drinking water. [Result] The 20 kinds of volatile organic compounds in drinking water all could be detected simultaneously by using HS-GC-FID method,and they all could be separated well. The HS-GC-FID method could analyze the detected substances qualitatively and quantitatively. In addition, this detection method was characterized by larger linear range of concentration, higher precision, higher detection limit and higher recovery rate. [Conclusion] Under certain conditions, HSGC can reduce the loss of volatile organic compound in drinking water and improve the sensitivity of detection. Moreover, the detection results meet the requirements by quality control.
文摘A flow-based iodometric extraction method for the determination of selenium sulfide was developed and applied to cosmeceutical products. Iodine which was generated from the reduction of selenium(IV) ions by iodide ion was on-line extracted using a polypropylene HFM (hollow fiber membrane) liquid extraction technique. The HFM extraction unit was constructed and used to support an organic solvent (hexane) and separate between the organic phase and aqueous phase. The resulting purple extract was carried to a fiber optic spectrophotometric detector for the measurement at 521 nm. Parameters which affected the extraction efficiency, sensitivity and sample throughput such as iodide (selenium molar ratio, extraction time and washing time between the cycles) were investigated and optimized. A linear dynamic range of 80-373 mg.Lt selenium solution was obtained with an extraction time of 60 sec. The total analysis time including washing was about 180 sec which provided a sample throughput of approximately 20 samples'hr1 and excluded the sample pre-treatment. The recoveries for the determination of selenium in the forms of selenium dioxide and selenium sulfide were in the range of 103%-104% with 1%-3% RSD (relative standard deviation). The relative errors of this method which was applied for determination of selenium sulfide levels in an anti-dandruff shampoo and a cosmeceutical bead sample were both less than 2.5%.
基金supported by National Natural Science Foundation of China (Grant Nos. 61179018, 61372027, 61501489)Special Foundation for Mountain Tai Scholars
文摘A novel approach, which can handle ambiguous data from weak targets, is proposed within the randomized Hough transform track-before-detect(RHT-TBD) framework. The main idea is that, without the pre-detection and ambiguity resolution step at each time step, the ambiguous measurements are mapped by the multiple hypothesis ranging(MHR) procedure. In this way, all the information, based on the relativity in time and pulse repetition frequency(PRF) domains, can be gathered among different PRFs and integrated over time via a batch procedure. The final step is to perform the RHT with all the extended measurements, and the ambiguous data is unfolded while the detection decision is confirmed at the end of the processing chain.Unlike classic methods, the new approach resolves the problem of range ambiguity and detects the true track for targets. Finally, its application is illustrated to analyze and compare the performance between the proposed approach and the existing approach. Simulation results exhibit the effectiveness of this approach.