Two-phase flow distributions in the merged pipe distributor have still remained mal-uniformity problem and the causes have not clearly discovered yet. Therefore, the enhancement study is needed, absolutely. The experi...Two-phase flow distributions in the merged pipe distributor have still remained mal-uniformity problem and the causes have not clearly discovered yet. Therefore, the enhancement study is needed, absolutely. The experimental was carried out upon the distributor constructed by acrylics resembling merged triple pipe, 8 mm in diameter of inlet channel and two set 5 mm in diameter of each outlet channel, set horizontally sideways. Three flow patterns were fed, i.e., bubble, slug and stratified flow, observed via high speed video camera. The pressure distribution was measured by series of U-tube water gauge manometer. The flow patterns, phase distribution and pressure drop were analyzed by CFD software, validated by experimental data and compared by existing correlation, analytically. The experiment is extended by modeling, in order to vary three inclinations of distributor: horizontally, 45° and vertically up-ward as well as to vary three outlet channel lengths with length ratio lc/dc: 3.2, 10 and 70. It was revealed that the two-phase flow distribution tends to be mal-uniform and to transform to different flow pattern in outlet channels. These are promoted by different: outlet channel length, feeding two-phase flow pattern in inlet distributor and inclination angle. The changing of flow pattern is driven by fluctuating velocity in both upper and lower outlet channel.展开更多
This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investi...This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investigated tip geometries include fiat tip as the baseline and suction side squealer tip. The tip clearance of the baseline is 0.5% of the blade span. The static pressure rise characteristic curves of both the rotor and the stage are measured. The flow field at the exit of the rotor is measured by a 5-hole probe under design and off-design conditions. The static pressure on the endwall of the rotor passage is also obtained. The results show that the pressure rise characteristic curves obtained by measuring the pressure on the end wall are almost unchanged by using the suction side squealer tip. The measuring results of the 5-hole probe show the static pressure and the total pressure in tip region is slightly greater than that of the flat tip at the design condition at the exit of the rotor. It also leads to greater averaged static pressure rise and total pressure. At the near stall condition, the averaged static pressure and total pressure is lower than the baseline which is related to the redistribution of the blade load caused by the suction side squealer tip.展开更多
文摘Two-phase flow distributions in the merged pipe distributor have still remained mal-uniformity problem and the causes have not clearly discovered yet. Therefore, the enhancement study is needed, absolutely. The experimental was carried out upon the distributor constructed by acrylics resembling merged triple pipe, 8 mm in diameter of inlet channel and two set 5 mm in diameter of each outlet channel, set horizontally sideways. Three flow patterns were fed, i.e., bubble, slug and stratified flow, observed via high speed video camera. The pressure distribution was measured by series of U-tube water gauge manometer. The flow patterns, phase distribution and pressure drop were analyzed by CFD software, validated by experimental data and compared by existing correlation, analytically. The experiment is extended by modeling, in order to vary three inclinations of distributor: horizontally, 45° and vertically up-ward as well as to vary three outlet channel lengths with length ratio lc/dc: 3.2, 10 and 70. It was revealed that the two-phase flow distribution tends to be mal-uniform and to transform to different flow pattern in outlet channels. These are promoted by different: outlet channel length, feeding two-phase flow pattern in inlet distributor and inclination angle. The changing of flow pattern is driven by fluctuating velocity in both upper and lower outlet channel.
基金funded by the National Natural Science Foundation of China,Grant No.51161130525 and 51136003supported by the 111 Project,No.B07009
文摘This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investigated tip geometries include fiat tip as the baseline and suction side squealer tip. The tip clearance of the baseline is 0.5% of the blade span. The static pressure rise characteristic curves of both the rotor and the stage are measured. The flow field at the exit of the rotor is measured by a 5-hole probe under design and off-design conditions. The static pressure on the endwall of the rotor passage is also obtained. The results show that the pressure rise characteristic curves obtained by measuring the pressure on the end wall are almost unchanged by using the suction side squealer tip. The measuring results of the 5-hole probe show the static pressure and the total pressure in tip region is slightly greater than that of the flat tip at the design condition at the exit of the rotor. It also leads to greater averaged static pressure rise and total pressure. At the near stall condition, the averaged static pressure and total pressure is lower than the baseline which is related to the redistribution of the blade load caused by the suction side squealer tip.