Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop me...Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sectional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is confirmed by a fundamental fluid dynamics analysis.展开更多
An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characte...An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characteristics,boiling heat transfer coefficient(HTC)increases with mass velocity of R245fa,while it decreases with the increment of saturation temperature and heat flux.With the increase of vapor quality,HTC has a maximum and the corresponding vapor quality is about 0.4,which varies with the operating conditions.When vapor quality is larger than the transition point,HTC can be promoted more remarkably at higher mass velocity or lower saturation temperature.Among the four selected correlations,KANDLIKAR correlation matches with 91.6%of experimental data within the deviation range of±25%,and the absolute mean deviation is 11.2%.Also,in terms of frictional pressure drop characteristics of flow boiling,the results of this study show that frictional pressure drop increases with mass velocity and heat flux of R245fa,while it decreases with the increment of saturation temperature.MULLER-STEINHAGEN-HECK correlation shows the best prediction accuracy for frictional pressure drop among the four widely used correlations.It covers 84.1%of experimental data within the deviation range of±20%,and the absolute mean deviation is 10.1%.展开更多
The transition from froth to spray regime on sieve trays was experimentally studied in an air/water simulator with 300mm diameter. It has been found that the regime transition occurs as the clear liquid height is equa...The transition from froth to spray regime on sieve trays was experimentally studied in an air/water simulator with 300mm diameter. It has been found that the regime transition occurs as the clear liquid height is equal to the residual pressure drop on the trays. A convenient and accurate technique was proposed for determination of the regime transition point. Based on analysis of the transition process at a sieve hole, a new formula which can be used to correlate the experimental results was provided.展开更多
The time-dependent liquid film thickness and pressure drop were measured by using parallel-wire conductance probes and capacitance differential-pressure transducers. Applying the eddy viscosity theory and an appropria...The time-dependent liquid film thickness and pressure drop were measured by using parallel-wire conductance probes and capacitance differential-pressure transducers. Applying the eddy viscosity theory and an appropriate correlation of interfacial sear stress,a new two-dimensional separated model of holdup and pressure drop of turbulent/turbulent gas-liquid stratified flow was presented. Prediction results agreed well with experimental data.展开更多
The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the P...The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the PCS with the voltage phase jump detection method which is one of the main causes of the disconnection. We modeled it in the simulation. When fault occurs, even though the residual voltage is more than 20% and the voltage sag time is within 1.0 s, the PCS disconnected by the voltage phase jump detection was confirmed in the simulation results. Ifa large number of PV systems are interconnected in the power system, this study is verified through the simulation that the interaction caused by the disconnection which generated by the voltage phase jump detection. This study is proposed threshold limit value of islanding detection. The validity of proposed method was verified through the simulation in this study.展开更多
A predictive current control algorithm for the Buck-Boost DC-DC converter is presented in this paper. The continuous time model of the system is properly introduced, then, by imposing a proper PWM modulation pattern, ...A predictive current control algorithm for the Buck-Boost DC-DC converter is presented in this paper. The continuous time model of the system is properly introduced, then, by imposing a proper PWM modulation pattern, its discrete time model is achieved. This last one is successfully employed in determining the steady state locus of the Buck-Boost converter, both in CCM (continuous conduction mode) and DCM (discontinuous conduction mode). A novel continuous time equivalent circuit of the converter is introduced too, with the aim of determining a ripple free representation of the state variables of the system, over both transient and steady state operation. Then, a predictive current control algorithm, suitable in both CCM and DCM, is developed and properly checked by means of computer simulations. The corresponding results have highlighted the effectiveness of the proposed modelling and of the predictive control algorithm, both in CCM and DCM.展开更多
文摘Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sectional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is confirmed by a fundamental fluid dynamics analysis.
基金Project(51606162)supported by the National Natural Science Foundation of ChinaProject(2018JJ2399)supported by the Natural Science Foundation of Hunan Province,China
文摘An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characteristics,boiling heat transfer coefficient(HTC)increases with mass velocity of R245fa,while it decreases with the increment of saturation temperature and heat flux.With the increase of vapor quality,HTC has a maximum and the corresponding vapor quality is about 0.4,which varies with the operating conditions.When vapor quality is larger than the transition point,HTC can be promoted more remarkably at higher mass velocity or lower saturation temperature.Among the four selected correlations,KANDLIKAR correlation matches with 91.6%of experimental data within the deviation range of±25%,and the absolute mean deviation is 11.2%.Also,in terms of frictional pressure drop characteristics of flow boiling,the results of this study show that frictional pressure drop increases with mass velocity and heat flux of R245fa,while it decreases with the increment of saturation temperature.MULLER-STEINHAGEN-HECK correlation shows the best prediction accuracy for frictional pressure drop among the four widely used correlations.It covers 84.1%of experimental data within the deviation range of±20%,and the absolute mean deviation is 10.1%.
基金Supported by the National Natural Science Foundation of China(No.29170288)
文摘The transition from froth to spray regime on sieve trays was experimentally studied in an air/water simulator with 300mm diameter. It has been found that the regime transition occurs as the clear liquid height is equal to the residual pressure drop on the trays. A convenient and accurate technique was proposed for determination of the regime transition point. Based on analysis of the transition process at a sieve hole, a new formula which can be used to correlate the experimental results was provided.
文摘The time-dependent liquid film thickness and pressure drop were measured by using parallel-wire conductance probes and capacitance differential-pressure transducers. Applying the eddy viscosity theory and an appropriate correlation of interfacial sear stress,a new two-dimensional separated model of holdup and pressure drop of turbulent/turbulent gas-liquid stratified flow was presented. Prediction results agreed well with experimental data.
文摘The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the PCS with the voltage phase jump detection method which is one of the main causes of the disconnection. We modeled it in the simulation. When fault occurs, even though the residual voltage is more than 20% and the voltage sag time is within 1.0 s, the PCS disconnected by the voltage phase jump detection was confirmed in the simulation results. Ifa large number of PV systems are interconnected in the power system, this study is verified through the simulation that the interaction caused by the disconnection which generated by the voltage phase jump detection. This study is proposed threshold limit value of islanding detection. The validity of proposed method was verified through the simulation in this study.
文摘A predictive current control algorithm for the Buck-Boost DC-DC converter is presented in this paper. The continuous time model of the system is properly introduced, then, by imposing a proper PWM modulation pattern, its discrete time model is achieved. This last one is successfully employed in determining the steady state locus of the Buck-Boost converter, both in CCM (continuous conduction mode) and DCM (discontinuous conduction mode). A novel continuous time equivalent circuit of the converter is introduced too, with the aim of determining a ripple free representation of the state variables of the system, over both transient and steady state operation. Then, a predictive current control algorithm, suitable in both CCM and DCM, is developed and properly checked by means of computer simulations. The corresponding results have highlighted the effectiveness of the proposed modelling and of the predictive control algorithm, both in CCM and DCM.