It is of importance to study and predict the possible buckling of submarine pipeline under thermal stress in pipeline design.Since soil resistance is not strong enough to restrain the large deformation of pipeline,hig...It is of importance to study and predict the possible buckling of submarine pipeline under thermal stress in pipeline design.Since soil resistance is not strong enough to restrain the large deformation of pipeline,high-order buckling modes occur very easily.Analytical solutions to high-order buckling modes were obtained in this paper.The relationships between buckling temperature and the amplitude or the wavelength of buckling modes were established.Analytical solutions were obtained to predict the occurrence and consequence of in-service buckling of a heated pipeline in an oil field.The effects of temperature difference and properties of subsoil on buckling modes were investigated.The results show that buckling will occur once temperature difference exceeds safe temperature;high-order pipeline buckling occurs very easily;the larger the friction coefficients are,the safer the submarine pipeline will be.展开更多
Knowledge of oxygen consumption rates and asphyxiation points in fish is important to determine appropriate stocking and water quality management in aquaculture. The oxygen consumption rate and asphyxiation point in C...Knowledge of oxygen consumption rates and asphyxiation points in fish is important to determine appropriate stocking and water quality management in aquaculture. The oxygen consumption rate and asphyxiation point in Chanodichthys mongolicus were detected under laboratory conditions using an improved respirometer chamber. The results revealed that more accurate estimates can be obtained by adjusting the volume of the respirometer chamber, which may avoid system errors caused by either repeatedly adjusting fish density or selecting different equipment specifications. The oxygen consumption rate and asphyxiation point of C. mongolicus increased with increasing water temperature and decreasing fish size. Changes in the C. mongolicus oxygen consumption rate were divided into three stages at water temperatures of 11-33~C: (I) a low temperature oxygen consumption rate stage when water temperature was 11-19~C, (2) the optimum temperature oxygen consumption rate stage when water temperature was 19-23~C, and (3) a high temperature oxygen consumption rate stage when water temperature was 〉27~C. The temperature quotients (Q10) obtained suggested that C. mongolicus preferred a temperature range of 19-23~C. At 19~C, C. mongolicus exhibited higher oxygen consumption rates during the day when the maximum values were observed at 10:00 and 14:00 than at night when the minimum occurred at 02:00.展开更多
For ground source heat utilization systems, pile heat exchangers are sometimes used. In order for these systems to achieve high performance, control of the system dynamics is important, and the underground temperature...For ground source heat utilization systems, pile heat exchangers are sometimes used. In order for these systems to achieve high performance, control of the system dynamics is important, and the underground temperature must he known. Typically, underground temperature is measured using a thermometer in a borehole. However, in the case of pile heat exchangers, a different method is required, making the system expensive to set up. To overcome this problem, the installation of underground thermometers in the heat exchanger piles themselves is proposed in the present study. The proposed thermometer system consists of thermocouples packed in grout such as silica sand within the piles. However, there is a possibility of measurement errors due to vertical thermal conduction in the steel pipes, and it is important to estimate the measurement accuracy before the development of this system. In the present study, the measurement accuracy is estimated using numerical simulations and then confirmed experimentally. The underground temperature profiles inside and outside the pile are compared. The results indicate that the proposed system offers sufficient accuracy for application to pile heat exchangers.展开更多
High-temperature heating surface such as superheater and reheater of large-sized utility boiler all experiences a relatively severe working conditions. The failure of boiler tubes will directly impact the safe and eco...High-temperature heating surface such as superheater and reheater of large-sized utility boiler all experiences a relatively severe working conditions. The failure of boiler tubes will directly impact the safe and economic operation of boiler. An on-line life monitoring model of high-temperature heating surface was set up according to the well-known L-M formula of the creep damages. The tube wall metal temperature and working stress was measured by on-line monitoring, and with this model, the real-time calculation of the life expenditure of the heating surface tube bundles were realized. Based on the technique the on-line life monitoring and management system of high-temperature heating surface was developed for a 300 MW utility boiler. An effective device was thus suggested for the implementation of the safe operation and the condition-based maintenance of utility boilers.展开更多
It is known that localized corrosion attack takes a preponderant role in the onset of stress corrosion cracking of pipeline steels in high pH conditions. Carbonate/bicarbonate solutions can be employed to study the lo...It is known that localized corrosion attack takes a preponderant role in the onset of stress corrosion cracking of pipeline steels in high pH conditions. Carbonate/bicarbonate solutions can be employed to study the localized corrosion behavior of these materials. In addition to the presence of chloride ions in the electrolyte, the solution temperature is also of prime importance to the onset of pitting corrosion. The aim of this work is to evaluate the influence of the testing temperature on the corrosion behavior of the API 5L X70 pipeline steel which is a standard material for gas pipelines in Brazil. Samples were exposed to a solution consisting of Na2CO3, NaHCO3 and NaCl at three different temperatures: RT (room temperature), 40 ℃ and 60 ℃. The corrosion morphology was observed using SEM (scanning electron microscopy). The results showed that pitting corrosion became facilitated when the steel was immersed at higher temperatures.展开更多
In recent years, PV (photovoltaic) systems have been installed rapidly around the world. However, there is often a delay in the practical application of fault detection in PV systems. In this study, the temperature ...In recent years, PV (photovoltaic) systems have been installed rapidly around the world. However, there is often a delay in the practical application of fault detection in PV systems. In this study, the temperature of BD (bypass diodes) mounted on PV modules was measured for simple and practical fault detection. The temperature of the BD of Module 31 was higher than other modules and a large current passed through one of the BDs. Measuring BD temperatures is easier than other conventional methods of fault detection. From the results of the rise in BD temperature under dark conditions, the increase in temperature increased linearly with increasing current flow. There is a proportional relationship between heat generated and the increasing temperature of the terminal box. The experimental results about surface temperature of the junction box in actual system operation suggested that the electric current through a BD in a terminal box can be known by measuring the surface temperature of the terminal box for PV module fault detection without a system shutdown. Moreover, we tried to evaluate temperature distribution of a terminal box using heat conduction equations. The evaluated results agreed well with the measured results.展开更多
The heat conduction equation is solved in this paper under specific boundary conditions.The coefficients of the obtained distribution equation are simplified with the piecewise integral method.Then the associated mode...The heat conduction equation is solved in this paper under specific boundary conditions.The coefficients of the obtained distribution equation are simplified with the piecewise integral method.Then the associated model for the cylindrical thermal equipment is established.The relationship of the surface temperatures,the material properties and the inner wall state of the cylindrical thermal equipment is described in the associated model.This model is applied to the inner wall running state monitoring of the main pipe.A multi-channel distributed optical fiber temperature measurement system is designed to acquire the external surface temperatures of the main pipe.Then the associated model can be used to analyze the surface temperature data of the main pipe.The location and the physical dimension of the inner wall defect can be got.Therefore,the inner wall defect monitoring of the main pipe can be realized.The feasibility of this method is verified by experiment.This method also provides a theoretical basis for the real-time monitoring of the main pipe’s internal state.展开更多
In order to clarify the structure of the cold flow discharged from the counter-flow vortex tube(VT), the temperature and pressure of the cold flow were measured, and the existence and behavior of the reversed flow at ...In order to clarify the structure of the cold flow discharged from the counter-flow vortex tube(VT), the temperature and pressure of the cold flow were measured, and the existence and behavior of the reversed flow at the cold exit was studied using a simple flow visualization technique consisting of a 0.75mm-diameter needle, and an oil paint droplet. It is observed through this experiment that the Pitot pressure at the cold exit center can either be lower or higher than atmospheric pressure, depending on the inlet pressure and the cold fraction, and that a reversed flow is observed when the Pitot pressure at the cold exit center is lower than atmospheric pressure. In addition, it is observed that when reducing the cold fraction from unity at any arbitrary inlet pressure, the region of reversed and colder flow in the central part of cold exit extends in the downstream direction.展开更多
In this paper, we present a stable single-photon detection method based on Si-avalanche photodiode(Si-APD) operating in Geiger mode with a large temperature variation range. By accurate temperature sensing and direct ...In this paper, we present a stable single-photon detection method based on Si-avalanche photodiode(Si-APD) operating in Geiger mode with a large temperature variation range. By accurate temperature sensing and direct current(DC) bias voltage compensation, the single-photon detector can work stably in Geiger mode from-40 °C to 35 °C with an almost constant avalanche gain. It provides a solution for single-photon detection at outdoor operation in all-weather conditions.展开更多
In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors(RADFETs) in experimental. The possible t...In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors(RADFETs) in experimental. The possible traps and defects induced by ions implantation in the gate-oxide and their further impacting on the sensitivity and dose range of RADFETs were analyzed qualitatively. Our devices had the dry/wet/dry sandwich gate-oxide of 420 nm thick. Different ion-implanting doses and post-annealing temperatures were carried out during the RADFETs fabrication. We built a real time auto-measurement system to realize the auto-state-switch between irradiation and read-out modes, and in-situ measurement of output voltage for ten devices in turn at once of radiation experiment. The threshold voltage, dose range and sensitivity of RADFETs were extracted and analyzed in detail. The results showed that the highest sensitivity of 229 mV/Gy achieved when the implant dose was2.2×1011 cm.2 and the post-annealing temperature was 1000°C, and the dose range of 34 Gy as well.展开更多
基金Supported by Innovative Research Groups of the National Natural Science Foundation of China(No.51021004)National Natural Science Foundation of China(No.40776055)+1 种基金Program for New Century Excellent Talents in University(NCET-11-0370)State Key Laboratory of Ocean Engineering Foundation(1002)
文摘It is of importance to study and predict the possible buckling of submarine pipeline under thermal stress in pipeline design.Since soil resistance is not strong enough to restrain the large deformation of pipeline,high-order buckling modes occur very easily.Analytical solutions to high-order buckling modes were obtained in this paper.The relationships between buckling temperature and the amplitude or the wavelength of buckling modes were established.Analytical solutions were obtained to predict the occurrence and consequence of in-service buckling of a heated pipeline in an oil field.The effects of temperature difference and properties of subsoil on buckling modes were investigated.The results show that buckling will occur once temperature difference exceeds safe temperature;high-order pipeline buckling occurs very easily;the larger the friction coefficients are,the safer the submarine pipeline will be.
基金Supported by the Central-Level Non-Profit Scientific Research Institutes Special Funds(Nos.2014A07XK04,HSY201403)the Harbin Science and Technology Project(No.2012AA6CN037)the National Key Technology Research and Development Program of China(No.2012BAD25B09)
文摘Knowledge of oxygen consumption rates and asphyxiation points in fish is important to determine appropriate stocking and water quality management in aquaculture. The oxygen consumption rate and asphyxiation point in Chanodichthys mongolicus were detected under laboratory conditions using an improved respirometer chamber. The results revealed that more accurate estimates can be obtained by adjusting the volume of the respirometer chamber, which may avoid system errors caused by either repeatedly adjusting fish density or selecting different equipment specifications. The oxygen consumption rate and asphyxiation point of C. mongolicus increased with increasing water temperature and decreasing fish size. Changes in the C. mongolicus oxygen consumption rate were divided into three stages at water temperatures of 11-33~C: (I) a low temperature oxygen consumption rate stage when water temperature was 11-19~C, (2) the optimum temperature oxygen consumption rate stage when water temperature was 19-23~C, and (3) a high temperature oxygen consumption rate stage when water temperature was 〉27~C. The temperature quotients (Q10) obtained suggested that C. mongolicus preferred a temperature range of 19-23~C. At 19~C, C. mongolicus exhibited higher oxygen consumption rates during the day when the maximum values were observed at 10:00 and 14:00 than at night when the minimum occurred at 02:00.
文摘For ground source heat utilization systems, pile heat exchangers are sometimes used. In order for these systems to achieve high performance, control of the system dynamics is important, and the underground temperature must he known. Typically, underground temperature is measured using a thermometer in a borehole. However, in the case of pile heat exchangers, a different method is required, making the system expensive to set up. To overcome this problem, the installation of underground thermometers in the heat exchanger piles themselves is proposed in the present study. The proposed thermometer system consists of thermocouples packed in grout such as silica sand within the piles. However, there is a possibility of measurement errors due to vertical thermal conduction in the steel pipes, and it is important to estimate the measurement accuracy before the development of this system. In the present study, the measurement accuracy is estimated using numerical simulations and then confirmed experimentally. The underground temperature profiles inside and outside the pile are compared. The results indicate that the proposed system offers sufficient accuracy for application to pile heat exchangers.
文摘High-temperature heating surface such as superheater and reheater of large-sized utility boiler all experiences a relatively severe working conditions. The failure of boiler tubes will directly impact the safe and economic operation of boiler. An on-line life monitoring model of high-temperature heating surface was set up according to the well-known L-M formula of the creep damages. The tube wall metal temperature and working stress was measured by on-line monitoring, and with this model, the real-time calculation of the life expenditure of the heating surface tube bundles were realized. Based on the technique the on-line life monitoring and management system of high-temperature heating surface was developed for a 300 MW utility boiler. An effective device was thus suggested for the implementation of the safe operation and the condition-based maintenance of utility boilers.
文摘It is known that localized corrosion attack takes a preponderant role in the onset of stress corrosion cracking of pipeline steels in high pH conditions. Carbonate/bicarbonate solutions can be employed to study the localized corrosion behavior of these materials. In addition to the presence of chloride ions in the electrolyte, the solution temperature is also of prime importance to the onset of pitting corrosion. The aim of this work is to evaluate the influence of the testing temperature on the corrosion behavior of the API 5L X70 pipeline steel which is a standard material for gas pipelines in Brazil. Samples were exposed to a solution consisting of Na2CO3, NaHCO3 and NaCl at three different temperatures: RT (room temperature), 40 ℃ and 60 ℃. The corrosion morphology was observed using SEM (scanning electron microscopy). The results showed that pitting corrosion became facilitated when the steel was immersed at higher temperatures.
文摘In recent years, PV (photovoltaic) systems have been installed rapidly around the world. However, there is often a delay in the practical application of fault detection in PV systems. In this study, the temperature of BD (bypass diodes) mounted on PV modules was measured for simple and practical fault detection. The temperature of the BD of Module 31 was higher than other modules and a large current passed through one of the BDs. Measuring BD temperatures is easier than other conventional methods of fault detection. From the results of the rise in BD temperature under dark conditions, the increase in temperature increased linearly with increasing current flow. There is a proportional relationship between heat generated and the increasing temperature of the terminal box. The experimental results about surface temperature of the junction box in actual system operation suggested that the electric current through a BD in a terminal box can be known by measuring the surface temperature of the terminal box for PV module fault detection without a system shutdown. Moreover, we tried to evaluate temperature distribution of a terminal box using heat conduction equations. The evaluated results agreed well with the measured results.
基金supported by the Special Foundation for State Major Basic Research Program of China(Grant No.2011ZX04002-101)
文摘The heat conduction equation is solved in this paper under specific boundary conditions.The coefficients of the obtained distribution equation are simplified with the piecewise integral method.Then the associated model for the cylindrical thermal equipment is established.The relationship of the surface temperatures,the material properties and the inner wall state of the cylindrical thermal equipment is described in the associated model.This model is applied to the inner wall running state monitoring of the main pipe.A multi-channel distributed optical fiber temperature measurement system is designed to acquire the external surface temperatures of the main pipe.Then the associated model can be used to analyze the surface temperature data of the main pipe.The location and the physical dimension of the inner wall defect can be got.Therefore,the inner wall defect monitoring of the main pipe can be realized.The feasibility of this method is verified by experiment.This method also provides a theoretical basis for the real-time monitoring of the main pipe’s internal state.
文摘In order to clarify the structure of the cold flow discharged from the counter-flow vortex tube(VT), the temperature and pressure of the cold flow were measured, and the existence and behavior of the reversed flow at the cold exit was studied using a simple flow visualization technique consisting of a 0.75mm-diameter needle, and an oil paint droplet. It is observed through this experiment that the Pitot pressure at the cold exit center can either be lower or higher than atmospheric pressure, depending on the inlet pressure and the cold fraction, and that a reversed flow is observed when the Pitot pressure at the cold exit center is lower than atmospheric pressure. In addition, it is observed that when reducing the cold fraction from unity at any arbitrary inlet pressure, the region of reversed and colder flow in the central part of cold exit extends in the downstream direction.
基金supported by the National Natural Science Foundation of China(No.11374105)
文摘In this paper, we present a stable single-photon detection method based on Si-avalanche photodiode(Si-APD) operating in Geiger mode with a large temperature variation range. By accurate temperature sensing and direct current(DC) bias voltage compensation, the single-photon detector can work stably in Geiger mode from-40 °C to 35 °C with an almost constant avalanche gain. It provides a solution for single-photon detection at outdoor operation in all-weather conditions.
基金supported by the National Basic Research Program of China(Grant No.2015CB352100)
文摘In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors(RADFETs) in experimental. The possible traps and defects induced by ions implantation in the gate-oxide and their further impacting on the sensitivity and dose range of RADFETs were analyzed qualitatively. Our devices had the dry/wet/dry sandwich gate-oxide of 420 nm thick. Different ion-implanting doses and post-annealing temperatures were carried out during the RADFETs fabrication. We built a real time auto-measurement system to realize the auto-state-switch between irradiation and read-out modes, and in-situ measurement of output voltage for ten devices in turn at once of radiation experiment. The threshold voltage, dose range and sensitivity of RADFETs were extracted and analyzed in detail. The results showed that the highest sensitivity of 229 mV/Gy achieved when the implant dose was2.2×1011 cm.2 and the post-annealing temperature was 1000°C, and the dose range of 34 Gy as well.