A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardwa...A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardware and software of this apparatus were designed,and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism,and the relationship between convection,evaporation,radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method,using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other,and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A:100%,region B:0%). Accordingly,it is feasible to measure BGL with COEM.展开更多
A colorimetric method has been established for a-glucosidase activity assay and its inhibitor screening. The method is based on the specific recognition between 1,4-phenylenediboronic acid (PDBA) and 4-aminophenyl-a...A colorimetric method has been established for a-glucosidase activity assay and its inhibitor screening. The method is based on the specific recognition between 1,4-phenylenediboronic acid (PDBA) and 4-aminophenyl-a-D-glucopyranoside (pAPG), which may induce aggregation of pAPG-functionalized gold nano- particles (AuNPs) to achieve color change of the test solution. Because pAPG is the substrate of α-glucosidase, the aggregation of AuNPs will be influenced by α-glucosidase since there is no coordination reactivity between PDBA and 4-aminobenzene, the hydrolyzed product of pAPG catalyzed by the enzyme. Therefore, a simple and easily-operated colorimetric method for the assay of a-glucosidase activity can be developed. Under the optimized experimental conditions, the ratios of absorbance at a wavelength of 650 nm to that at 520 nm vary linearly with the α-glucosidase activity within a range from 0.05 to 1.1 U/mL with a lowest detection limit of 0.004 U/mL. Moreover, using the proposed method, the inhibition effect of gallic acid and quercetin on a-glucosidase activity can be tested with IC50 values of 1.16 mM and 1.82 μM, respectively. Thus, the method has a great potential not only for the detection of a-glucosidase activity, but also for the screening of its inhibitors.展开更多
基金Project(07JJ6133) supported by the Natural Science Foundation of Hunan Province, China
文摘A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardware and software of this apparatus were designed,and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism,and the relationship between convection,evaporation,radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method,using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other,and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A:100%,region B:0%). Accordingly,it is feasible to measure BGL with COEM.
文摘A colorimetric method has been established for a-glucosidase activity assay and its inhibitor screening. The method is based on the specific recognition between 1,4-phenylenediboronic acid (PDBA) and 4-aminophenyl-a-D-glucopyranoside (pAPG), which may induce aggregation of pAPG-functionalized gold nano- particles (AuNPs) to achieve color change of the test solution. Because pAPG is the substrate of α-glucosidase, the aggregation of AuNPs will be influenced by α-glucosidase since there is no coordination reactivity between PDBA and 4-aminobenzene, the hydrolyzed product of pAPG catalyzed by the enzyme. Therefore, a simple and easily-operated colorimetric method for the assay of a-glucosidase activity can be developed. Under the optimized experimental conditions, the ratios of absorbance at a wavelength of 650 nm to that at 520 nm vary linearly with the α-glucosidase activity within a range from 0.05 to 1.1 U/mL with a lowest detection limit of 0.004 U/mL. Moreover, using the proposed method, the inhibition effect of gallic acid and quercetin on a-glucosidase activity can be tested with IC50 values of 1.16 mM and 1.82 μM, respectively. Thus, the method has a great potential not only for the detection of a-glucosidase activity, but also for the screening of its inhibitors.