To realize automatic control of automobile transmission performance test stand Methods The automatic control technique of the lubricant temperature,the program- controll- edautomaticshifting of the transmission,the c...To realize automatic control of automobile transmission performance test stand Methods The automatic control technique of the lubricant temperature,the program- controll- edautomaticshifting of the transmission,the continuous adjusting of revolution speed and load, data-acquisition and data real-time processing were adopted.Results The lubricant temperature was controlled at the set temperature ±2℃.The automatic shifting of the trans- mission is simple,reliable and accurate.The automatic adjusting of load and rotation speed is rapidandaccurate,the torque divergence is ±1N·m,the rotation speed divergence is ±5r/min Conclusion The four kinds of techniques are applied into the automobile transmission perfor- mance test stand successfully. mancetest stand successfully.展开更多
In order to solve the problem of artificial generation and low efficiency of test sequences for zone controller (ZC), a model-based automatic generation method of test sequence is proposed. Firstly, the timed automata...In order to solve the problem of artificial generation and low efficiency of test sequences for zone controller (ZC), a model-based automatic generation method of test sequence is proposed. Firstly, the timed automata model is established based on function analysis of the zone controller, and the correctness of the model is verified by UPPAAL. Then by parsing the timed automata model files, state information and transition conditions can be extracted to generate test case sets. Finally, according to the serialization conditions of test cases, the test cases are serialized into test sequences by using the improved depth first search algorithm. A case, the ZC controls the train running within its jurisdiction, shows that the method is correct and can effectively improve the efficiency of test sequence generation.展开更多
Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is ...Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is associated with a substantial EE, often exceeding 20%, possibly due to intrinsic variability of mechanical efficiency. Methods 1850 adults (68% men), aged 18 to 91 years, underwent maximal cycle ergometer cardiopulmonary exercise testing. Cardiorespiratory fitness (CRF) was assessed relative to sex and age [younger (18 to 35 years), middle-aged (36 to 60 years) and older (〉 60 years)]. VO2max [mL.(kg.min)-1] was directly measured by assessment of gas exchange and estimated using sex and population specific-equations. Measured and estimated values of VO2max and related EE were compared among the three age- and sex-specific groups. Results Directly measured VO2max of men and women were 29.5 ± 10.5 mL.(kg.min)-1 and 24.2 ± 9.0 mL.(kg·min) -1 (P 〈 0.01). EE [mL·(kg·min)-1] and percent errors (%E) for men and women had similar values, 0.5 ± 3.2 and 0.4 ± 2.9 mL·(kg·min)-1, and -0.8 ± 13.1% and -1.7 ± 15.4% (P 〉 0.05), respectively. EE and %E for each age-group were, respectively, for men: younger = 1.9 ± 4.1 mL·(kg·min)-1 and 3.8 ± 10.5%, middle-aged = 0.6 ± 3.1 mL.(kg·min)-1 and 0.4 ± 10.3%, older = -0.2 ± 2.7 mL·(kg·min) -1 and -4.2 ± 16.6% (P 〈 0.01); and for women: younger = 1.2 ± 3.1 mL.(kg.min)-1 and 2.7 ±10.0%, middle-aged = 0.7 ± 2.8 mL·(kg·min)-1 and 0.5 ± 11.1%, older = -0.8 ± 2.3 mL-(kg·min)-1 and -9.5 ± 22.4% (P 〈 0.01). Conclusion VO2max were underestimated in younger age-groups and were overestimated in older age groups. Age significantly influences the magnitude of the EE of VO2max in both men and women and should be considered when CRF is estimated using population specific equations, rather than directly measured.展开更多
文摘To realize automatic control of automobile transmission performance test stand Methods The automatic control technique of the lubricant temperature,the program- controll- edautomaticshifting of the transmission,the continuous adjusting of revolution speed and load, data-acquisition and data real-time processing were adopted.Results The lubricant temperature was controlled at the set temperature ±2℃.The automatic shifting of the trans- mission is simple,reliable and accurate.The automatic adjusting of load and rotation speed is rapidandaccurate,the torque divergence is ±1N·m,the rotation speed divergence is ±5r/min Conclusion The four kinds of techniques are applied into the automobile transmission perfor- mance test stand successfully. mancetest stand successfully.
文摘In order to solve the problem of artificial generation and low efficiency of test sequences for zone controller (ZC), a model-based automatic generation method of test sequence is proposed. Firstly, the timed automata model is established based on function analysis of the zone controller, and the correctness of the model is verified by UPPAAL. Then by parsing the timed automata model files, state information and transition conditions can be extracted to generate test case sets. Finally, according to the serialization conditions of test cases, the test cases are serialized into test sequences by using the improved depth first search algorithm. A case, the ZC controls the train running within its jurisdiction, shows that the method is correct and can effectively improve the efficiency of test sequence generation.
文摘Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is associated with a substantial EE, often exceeding 20%, possibly due to intrinsic variability of mechanical efficiency. Methods 1850 adults (68% men), aged 18 to 91 years, underwent maximal cycle ergometer cardiopulmonary exercise testing. Cardiorespiratory fitness (CRF) was assessed relative to sex and age [younger (18 to 35 years), middle-aged (36 to 60 years) and older (〉 60 years)]. VO2max [mL.(kg.min)-1] was directly measured by assessment of gas exchange and estimated using sex and population specific-equations. Measured and estimated values of VO2max and related EE were compared among the three age- and sex-specific groups. Results Directly measured VO2max of men and women were 29.5 ± 10.5 mL.(kg.min)-1 and 24.2 ± 9.0 mL.(kg·min) -1 (P 〈 0.01). EE [mL·(kg·min)-1] and percent errors (%E) for men and women had similar values, 0.5 ± 3.2 and 0.4 ± 2.9 mL·(kg·min)-1, and -0.8 ± 13.1% and -1.7 ± 15.4% (P 〉 0.05), respectively. EE and %E for each age-group were, respectively, for men: younger = 1.9 ± 4.1 mL·(kg·min)-1 and 3.8 ± 10.5%, middle-aged = 0.6 ± 3.1 mL.(kg·min)-1 and 0.4 ± 10.3%, older = -0.2 ± 2.7 mL·(kg·min) -1 and -4.2 ± 16.6% (P 〈 0.01); and for women: younger = 1.2 ± 3.1 mL.(kg.min)-1 and 2.7 ±10.0%, middle-aged = 0.7 ± 2.8 mL·(kg·min)-1 and 0.5 ± 11.1%, older = -0.8 ± 2.3 mL-(kg·min)-1 and -9.5 ± 22.4% (P 〈 0.01). Conclusion VO2max were underestimated in younger age-groups and were overestimated in older age groups. Age significantly influences the magnitude of the EE of VO2max in both men and women and should be considered when CRF is estimated using population specific equations, rather than directly measured.