This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transfor...This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transformers, this diagnostic method has become more important in recent years. The current state, basics and principles of operations, proceedings as well as advantages of PD-measurement methods are covered. Furthermore problems and proposed solutions are discussed. Bushings and tap changers are not discussed in detail. In many cases, one single diagnostic method does not have the ability to sufficiently evaluate a power transformer. Therefore, a variety of diagnostic methods came up over times, which are commonly used by now. To expand the evaluation opportunities of power transformers, science strives to develop new diagnostic methods as well as to improve the existing ones. Furthermore, environmentally friendly and hardly inflammable ester liquids are examined for the use at power transformers and PD-measurement at HVDC (high voltage direct current) converter transformers as well. Potential diagnostic options and respectively current developments and findings in the field of oil-paper-insulation systems are outlined conclusively.展开更多
Gas puffing ( GP ) is one of the fuelling ways for raising electron density and for plasma establishment. The HL-2A discharge relies only on ohmic transformer without pre-ionization.
Due to the difficulty and weakness of current stress measurement methods in deep soft rock, a new rheological stress recovery method of the determination of the three-dimensional(3D) stress tensor is proposed. It is s...Due to the difficulty and weakness of current stress measurement methods in deep soft rock, a new rheological stress recovery method of the determination of the three-dimensional(3D) stress tensor is proposed. It is supposed that rock stresses will recovery gradually with time and can be measured by embedding transducers into the borehole. In order to explore the applicability and accuracy of this method, analytical solutions are developed for stress measurement with the rheological stress recovery method in a viscoelastic surrounding rock, the rheological properties of which are depicted as both the Burger's model and a 3-parameter solid model. In such conditions, explicit analytical expressions for predicting time-dependent pressures on the transducer are derived. A parametric analysis is then adopted to investigate the influences of the grout solidification time and the mechanical properties of the grout layer. The results indicate that this method is suitable for stress measurement in deep soft rock, the characteristics of which are soft, fractured and subjected to high geo-stress.展开更多
文摘This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transformers, this diagnostic method has become more important in recent years. The current state, basics and principles of operations, proceedings as well as advantages of PD-measurement methods are covered. Furthermore problems and proposed solutions are discussed. Bushings and tap changers are not discussed in detail. In many cases, one single diagnostic method does not have the ability to sufficiently evaluate a power transformer. Therefore, a variety of diagnostic methods came up over times, which are commonly used by now. To expand the evaluation opportunities of power transformers, science strives to develop new diagnostic methods as well as to improve the existing ones. Furthermore, environmentally friendly and hardly inflammable ester liquids are examined for the use at power transformers and PD-measurement at HVDC (high voltage direct current) converter transformers as well. Potential diagnostic options and respectively current developments and findings in the field of oil-paper-insulation systems are outlined conclusively.
文摘Gas puffing ( GP ) is one of the fuelling ways for raising electron density and for plasma establishment. The HL-2A discharge relies only on ohmic transformer without pre-ionization.
基金supported by the National Basic Research Program of China (No.2014CB046904)the National Natural Science Foundation of China (Nos.41130742 and 11302242)
文摘Due to the difficulty and weakness of current stress measurement methods in deep soft rock, a new rheological stress recovery method of the determination of the three-dimensional(3D) stress tensor is proposed. It is supposed that rock stresses will recovery gradually with time and can be measured by embedding transducers into the borehole. In order to explore the applicability and accuracy of this method, analytical solutions are developed for stress measurement with the rheological stress recovery method in a viscoelastic surrounding rock, the rheological properties of which are depicted as both the Burger's model and a 3-parameter solid model. In such conditions, explicit analytical expressions for predicting time-dependent pressures on the transducer are derived. A parametric analysis is then adopted to investigate the influences of the grout solidification time and the mechanical properties of the grout layer. The results indicate that this method is suitable for stress measurement in deep soft rock, the characteristics of which are soft, fractured and subjected to high geo-stress.