This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. Th...This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. The study was carried out using three saturated salt solutions, which are Potassium Acetate 22.5%, Potassium Iodide 68.9% and Potassium Sulphate 97.3% to cover low, medium and high relative humidity. The study was carried out using different shapes and volumes half liter spherical, liter spherical and liter conical per each salt which was prepared. The apparatus which used in measurement system in the first time are the same which used after ten years. The results show that the change of relative humidity value after ten years ranged from 0.1% to 0.7%. This value is suitable within uncertainty + 2%. The period of stability for each run for all cells was found to be more than five hours and this period enough for calibration. The measurements show that the cells are stable for more than ten years with accepted value.展开更多
A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measur...A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.展开更多
Objective: The objective of this work was to establish adequate tolerance limits based on a certain defined institutional indices and generate published data presenting our results to the radiotherapy community. Metho...Objective: The objective of this work was to establish adequate tolerance limits based on a certain defined institutional indices and generate published data presenting our results to the radiotherapy community. Methods: One hundred paediatric patients were treated using 6-MV X-ray beams produced by Siemens ONCOR Expression linear accelerator. The clinical step-and-shoot intensity-modulated radiation therapy (IMRT) treatment plans were designed using KonRad release 2.2.23. For two treatment sites (abdomen, head and neck), the fluence maps generated by the treatment planning system were all delivered for the quality assurance (QA) which included absolute dose verification for all treatment fields, relative dose verification for each treatment field. Results: The 724 fluence maps were analyzed at three different criteria using the gamma index tool. The 3% dose difference of local prescribed dose /3 mm was considered adequate. The passing rate for all fields of all plans always exceeded 70%. The dose differences between the measured and calculated doses ranged from -2.2% to +4% [mean and standard deviation (s): 1.4 ± 1.5] for the abdominal case, and from -3.3% to +5.6% (1.3 ± 1.6) for head and neck case with total confidence limit 0.046 (4.6%). The 14/100 (14%) of the absolute point dose measurements were out of ±3% from the dose predicted by the treatment planning system. Only two cases were below -3%, while 12 cases over +3%. Conclusion: At 3% dose difference of local prescribed dose /3 mm criteria, a 75% passing a gamma criterion and 3% for absolute point dose can be achieved for abdomen and head and neck treatments site. We considered the tolerance limits based on these indices for IMRT QA adequate.展开更多
文摘This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. The study was carried out using three saturated salt solutions, which are Potassium Acetate 22.5%, Potassium Iodide 68.9% and Potassium Sulphate 97.3% to cover low, medium and high relative humidity. The study was carried out using different shapes and volumes half liter spherical, liter spherical and liter conical per each salt which was prepared. The apparatus which used in measurement system in the first time are the same which used after ten years. The results show that the change of relative humidity value after ten years ranged from 0.1% to 0.7%. This value is suitable within uncertainty + 2%. The period of stability for each run for all cells was found to be more than five hours and this period enough for calibration. The measurements show that the cells are stable for more than ten years with accepted value.
文摘A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.
文摘Objective: The objective of this work was to establish adequate tolerance limits based on a certain defined institutional indices and generate published data presenting our results to the radiotherapy community. Methods: One hundred paediatric patients were treated using 6-MV X-ray beams produced by Siemens ONCOR Expression linear accelerator. The clinical step-and-shoot intensity-modulated radiation therapy (IMRT) treatment plans were designed using KonRad release 2.2.23. For two treatment sites (abdomen, head and neck), the fluence maps generated by the treatment planning system were all delivered for the quality assurance (QA) which included absolute dose verification for all treatment fields, relative dose verification for each treatment field. Results: The 724 fluence maps were analyzed at three different criteria using the gamma index tool. The 3% dose difference of local prescribed dose /3 mm was considered adequate. The passing rate for all fields of all plans always exceeded 70%. The dose differences between the measured and calculated doses ranged from -2.2% to +4% [mean and standard deviation (s): 1.4 ± 1.5] for the abdominal case, and from -3.3% to +5.6% (1.3 ± 1.6) for head and neck case with total confidence limit 0.046 (4.6%). The 14/100 (14%) of the absolute point dose measurements were out of ±3% from the dose predicted by the treatment planning system. Only two cases were below -3%, while 12 cases over +3%. Conclusion: At 3% dose difference of local prescribed dose /3 mm criteria, a 75% passing a gamma criterion and 3% for absolute point dose can be achieved for abdomen and head and neck treatments site. We considered the tolerance limits based on these indices for IMRT QA adequate.