The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acqu...The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acquisition.The equivalent blackbody temperature is obtained by the temperature calibration model that represents the quantitative relation,at a certain integration time,between the gray level value and the equivalent blackbody temperature.The temperature calibration model has been acquired by the curve fitting with the experimental data of blackbody temperature calibration using Origin 6.0.Then the target radiance can be determined by the radiant flux equivalence model built on condition that the target radiant flux received by the infrared detector is equivalent to that of the blackbody placed in front of the infrared detector at a close distance.This measuring method is based on the temperature calibration parameters and real image information,so it can avoid subjectivity of the traditional theory modeling methods.展开更多
This paper presents the method for the performance calibration of AACMM (articulated arm coordinate measuring machines) according to ASME B89.4.22 Standard. The growing use of this class of measurement equipment has...This paper presents the method for the performance calibration of AACMM (articulated arm coordinate measuring machines) according to ASME B89.4.22 Standard. The growing use of this class of measurement equipment has been accompanied by an absence of authorized laboratories to provide calibration certificates for its performance. Due to ASME B89.4.22 and VD12617-9 are nowadays the unique standards in the field of AACMM verification, IK4 Tekniker has compared both of them in order to develop internal test procedures to yield reliable performance calibration results. As a result, IK4 Tekniker has been recognized by the Spanish Accreditation Body (ENAC) in the field of AACMM calibration. Internal test procedures and uncertainty evaluation analysis have been developed as well as ENAC certificated reference test equipments have been acquired to ensure a suitable AACMM calibration process.展开更多
This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. Th...This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. The study was carried out using three saturated salt solutions, which are Potassium Acetate 22.5%, Potassium Iodide 68.9% and Potassium Sulphate 97.3% to cover low, medium and high relative humidity. The study was carried out using different shapes and volumes half liter spherical, liter spherical and liter conical per each salt which was prepared. The apparatus which used in measurement system in the first time are the same which used after ten years. The results show that the change of relative humidity value after ten years ranged from 0.1% to 0.7%. This value is suitable within uncertainty + 2%. The period of stability for each run for all cells was found to be more than five hours and this period enough for calibration. The measurements show that the cells are stable for more than ten years with accepted value.展开更多
基金Supported by Innovation Project of Chinese Academy of Sciences(Grant No.C04708Z)
文摘The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acquisition.The equivalent blackbody temperature is obtained by the temperature calibration model that represents the quantitative relation,at a certain integration time,between the gray level value and the equivalent blackbody temperature.The temperature calibration model has been acquired by the curve fitting with the experimental data of blackbody temperature calibration using Origin 6.0.Then the target radiance can be determined by the radiant flux equivalence model built on condition that the target radiant flux received by the infrared detector is equivalent to that of the blackbody placed in front of the infrared detector at a close distance.This measuring method is based on the temperature calibration parameters and real image information,so it can avoid subjectivity of the traditional theory modeling methods.
文摘This paper presents the method for the performance calibration of AACMM (articulated arm coordinate measuring machines) according to ASME B89.4.22 Standard. The growing use of this class of measurement equipment has been accompanied by an absence of authorized laboratories to provide calibration certificates for its performance. Due to ASME B89.4.22 and VD12617-9 are nowadays the unique standards in the field of AACMM verification, IK4 Tekniker has compared both of them in order to develop internal test procedures to yield reliable performance calibration results. As a result, IK4 Tekniker has been recognized by the Spanish Accreditation Body (ENAC) in the field of AACMM calibration. Internal test procedures and uncertainty evaluation analysis have been developed as well as ENAC certificated reference test equipments have been acquired to ensure a suitable AACMM calibration process.
文摘This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. The study was carried out using three saturated salt solutions, which are Potassium Acetate 22.5%, Potassium Iodide 68.9% and Potassium Sulphate 97.3% to cover low, medium and high relative humidity. The study was carried out using different shapes and volumes half liter spherical, liter spherical and liter conical per each salt which was prepared. The apparatus which used in measurement system in the first time are the same which used after ten years. The results show that the change of relative humidity value after ten years ranged from 0.1% to 0.7%. This value is suitable within uncertainty + 2%. The period of stability for each run for all cells was found to be more than five hours and this period enough for calibration. The measurements show that the cells are stable for more than ten years with accepted value.