RCS测量标校中采用无人机吊放标准球的解决方案研究 被引量:7
1
作者 孙军 孙保杰 《舰船电子对抗》 2016年第4期19-24,共6页
研究设计了采用无人机吊放金属标准球进行雷达截面(RCS)标校的方案,旨在解决目前RCS测量中采用气球或风筝吊放方式受天气影响等标校成功率不高的瓶颈问题。设计方案在相关飞行性能评估平台进行了测试验证,结果表明能满足RCS测量中标校... 研究设计了采用无人机吊放金属标准球进行雷达截面(RCS)标校的方案,旨在解决目前RCS测量中采用气球或风筝吊放方式受天气影响等标校成功率不高的瓶颈问题。设计方案在相关飞行性能评估平台进行了测试验证,结果表明能满足RCS测量中标校的需求。 展开更多
关键词 无人机 雷达截面 测量标校
下载PDF
大中型矩形风管风量风速测量及标校技术研究
2
作者 杨世杰 《测控技术》 CSCD 2018年第B11期113-115,共3页
首先梳理、分析了大中型管道风流速流量测量及标校疑难点问题,其次对风量风速测量标校的关键点进行研究,在此基础上,提出了大中型矩形风管风量风速测量及标校方案。
关键词 大中型 矩形风管 风量风速 测量标校
下载PDF
Infrared radiation measurement of the aerial target based on temperature calibration and target images 被引量:2
3
作者 CAO Xi-zheng GUO Li-hong LI Zhuo 《Optoelectronics Letters》 EI 2006年第6期463-467,共5页
The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acqu... The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acquisition.The equivalent blackbody temperature is obtained by the temperature calibration model that represents the quantitative relation,at a certain integration time,between the gray level value and the equivalent blackbody temperature.The temperature calibration model has been acquired by the curve fitting with the experimental data of blackbody temperature calibration using Origin 6.0.Then the target radiance can be determined by the radiant flux equivalence model built on condition that the target radiant flux received by the infrared detector is equivalent to that of the blackbody placed in front of the infrared detector at a close distance.This measuring method is based on the temperature calibration parameters and real image information,so it can avoid subjectivity of the traditional theory modeling methods. 展开更多
关键词 红外线辐射测量 温度 图像 滤波算法
下载PDF
Performance Calibration of Articulated Arm Coordinate Measuring Machine 被引量:5
4
作者 Unai Mutilba Gorka Kortaberria Aitor Olarra Antonio Gutierrez 《Journal of Mechanics Engineering and Automation》 2013年第10期602-608,共7页
This paper presents the method for the performance calibration of AACMM (articulated arm coordinate measuring machines) according to ASME B89.4.22 Standard. The growing use of this class of measurement equipment has... This paper presents the method for the performance calibration of AACMM (articulated arm coordinate measuring machines) according to ASME B89.4.22 Standard. The growing use of this class of measurement equipment has been accompanied by an absence of authorized laboratories to provide calibration certificates for its performance. Due to ASME B89.4.22 and VD12617-9 are nowadays the unique standards in the field of AACMM verification, IK4 Tekniker has compared both of them in order to develop internal test procedures to yield reliable performance calibration results. As a result, IK4 Tekniker has been recognized by the Spanish Accreditation Body (ENAC) in the field of AACMM calibration. Internal test procedures and uncertainty evaluation analysis have been developed as well as ENAC certificated reference test equipments have been acquired to ensure a suitable AACMM calibration process. 展开更多
关键词 AACMM performance calibration ASME B89.4.22 ENAC UNCERTAINTY
下载PDF
Study of Stability of Saturated Salt Solutions Cells
5
作者 Essam Eldin Mahmoud 《Journal of Physical Science and Application》 2015年第5期330-333,共4页
This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. Th... This paper study stability of saturated salt solutions cells at 25 ℃. These cells were prepared and measured at National Institute for Standard (NIS-Egypt) to study the stability of the saturated salt solutions. The study was carried out using three saturated salt solutions, which are Potassium Acetate 22.5%, Potassium Iodide 68.9% and Potassium Sulphate 97.3% to cover low, medium and high relative humidity. The study was carried out using different shapes and volumes half liter spherical, liter spherical and liter conical per each salt which was prepared. The apparatus which used in measurement system in the first time are the same which used after ten years. The results show that the change of relative humidity value after ten years ranged from 0.1% to 0.7%. This value is suitable within uncertainty + 2%. The period of stability for each run for all cells was found to be more than five hours and this period enough for calibration. The measurements show that the cells are stable for more than ten years with accepted value. 展开更多
关键词 Saturated salt solutions STABILITY relative humidity dew-point sensor and cells.
下载PDF