Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is ...Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is associated with a substantial EE, often exceeding 20%, possibly due to intrinsic variability of mechanical efficiency. Methods 1850 adults (68% men), aged 18 to 91 years, underwent maximal cycle ergometer cardiopulmonary exercise testing. Cardiorespiratory fitness (CRF) was assessed relative to sex and age [younger (18 to 35 years), middle-aged (36 to 60 years) and older (〉 60 years)]. VO2max [mL.(kg.min)-1] was directly measured by assessment of gas exchange and estimated using sex and population specific-equations. Measured and estimated values of VO2max and related EE were compared among the three age- and sex-specific groups. Results Directly measured VO2max of men and women were 29.5 ± 10.5 mL.(kg.min)-1 and 24.2 ± 9.0 mL.(kg·min) -1 (P 〈 0.01). EE [mL·(kg·min)-1] and percent errors (%E) for men and women had similar values, 0.5 ± 3.2 and 0.4 ± 2.9 mL·(kg·min)-1, and -0.8 ± 13.1% and -1.7 ± 15.4% (P 〉 0.05), respectively. EE and %E for each age-group were, respectively, for men: younger = 1.9 ± 4.1 mL·(kg·min)-1 and 3.8 ± 10.5%, middle-aged = 0.6 ± 3.1 mL.(kg·min)-1 and 0.4 ± 10.3%, older = -0.2 ± 2.7 mL·(kg·min) -1 and -4.2 ± 16.6% (P 〈 0.01); and for women: younger = 1.2 ± 3.1 mL.(kg.min)-1 and 2.7 ±10.0%, middle-aged = 0.7 ± 2.8 mL·(kg·min)-1 and 0.5 ± 11.1%, older = -0.8 ± 2.3 mL-(kg·min)-1 and -9.5 ± 22.4% (P 〈 0.01). Conclusion VO2max were underestimated in younger age-groups and were overestimated in older age groups. Age significantly influences the magnitude of the EE of VO2max in both men and women and should be considered when CRF is estimated using population specific equations, rather than directly measured.展开更多
In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft a...In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft and the spot position on the circular trajectory,the roll angle is calculated quickly and conveniently using a simple algorithm.Only a mirror,a coupler and a fine shaft are contained in the measurement system besides the photoelectronic autocollimator.Aiming at the terrible measurement error induced by the axis wobbly error,two measurement schemes are proposed,which are linking the fine precision shaft to the measured shaft for reducing the axis wobbly error and using the segment measurement to enlarge the radius of the circular trajectory.The experimental results show that the measurement error is decreased by ±0.38°.The roll angle error of the mechanism is ±0.14°,and the measurement precision is about ±2′.The proposed method can be widely used in the engineering fields.展开更多
文摘Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is associated with a substantial EE, often exceeding 20%, possibly due to intrinsic variability of mechanical efficiency. Methods 1850 adults (68% men), aged 18 to 91 years, underwent maximal cycle ergometer cardiopulmonary exercise testing. Cardiorespiratory fitness (CRF) was assessed relative to sex and age [younger (18 to 35 years), middle-aged (36 to 60 years) and older (〉 60 years)]. VO2max [mL.(kg.min)-1] was directly measured by assessment of gas exchange and estimated using sex and population specific-equations. Measured and estimated values of VO2max and related EE were compared among the three age- and sex-specific groups. Results Directly measured VO2max of men and women were 29.5 ± 10.5 mL.(kg.min)-1 and 24.2 ± 9.0 mL.(kg·min) -1 (P 〈 0.01). EE [mL·(kg·min)-1] and percent errors (%E) for men and women had similar values, 0.5 ± 3.2 and 0.4 ± 2.9 mL·(kg·min)-1, and -0.8 ± 13.1% and -1.7 ± 15.4% (P 〉 0.05), respectively. EE and %E for each age-group were, respectively, for men: younger = 1.9 ± 4.1 mL·(kg·min)-1 and 3.8 ± 10.5%, middle-aged = 0.6 ± 3.1 mL.(kg·min)-1 and 0.4 ± 10.3%, older = -0.2 ± 2.7 mL·(kg·min) -1 and -4.2 ± 16.6% (P 〈 0.01); and for women: younger = 1.2 ± 3.1 mL.(kg.min)-1 and 2.7 ±10.0%, middle-aged = 0.7 ± 2.8 mL·(kg·min)-1 and 0.5 ± 11.1%, older = -0.8 ± 2.3 mL-(kg·min)-1 and -9.5 ± 22.4% (P 〈 0.01). Conclusion VO2max were underestimated in younger age-groups and were overestimated in older age groups. Age significantly influences the magnitude of the EE of VO2max in both men and women and should be considered when CRF is estimated using population specific equations, rather than directly measured.
基金supported by the National Natural Science Foundation of China(Nos.111742741117427961205021 and 11204299)
文摘In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft and the spot position on the circular trajectory,the roll angle is calculated quickly and conveniently using a simple algorithm.Only a mirror,a coupler and a fine shaft are contained in the measurement system besides the photoelectronic autocollimator.Aiming at the terrible measurement error induced by the axis wobbly error,two measurement schemes are proposed,which are linking the fine precision shaft to the measured shaft for reducing the axis wobbly error and using the segment measurement to enlarge the radius of the circular trajectory.The experimental results show that the measurement error is decreased by ±0.38°.The roll angle error of the mechanism is ±0.14°,and the measurement precision is about ±2′.The proposed method can be widely used in the engineering fields.