In order to overcome the inconvenience of manual bubble counting, a bubble counter based on photoelectric technique aiming for automatically detecting and measuring minute gas leakage of cryogenic valves is proposed. ...In order to overcome the inconvenience of manual bubble counting, a bubble counter based on photoelectric technique aiming for automatically detecting and measuring minute gas leakage of cryogenic valves is proposed. Experiments have been conducted on a self-built apparatus, testing the performance with different gas inlet strategies (bottom gas-inlet strategy and side gas-inlet strategy) and the influence of gas pipe length (0, 1, 2, 4, 6, 8, 10 m) and leakage rate (around 10, 20, 30, 40 bubbles/min) on first bubble time and bubble rate. A buffer of 110 cm3 is inserted between leakage source and gas pipe to simulate the down- stream cavum adjacent to the valve clack. Based on analyzing the experimental data, experiential parameters have also been summarized to guide leakage detection and measurement for engineering applications. A practical system has already been suc- cessfully applied in a cryogenic testing apparatus for cryogenic valves.展开更多
An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane de...An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane desalter was used to reduce the high concentrations of sodium salts in samples. In this method, trace nitrate was eluted from the concentrator column to the analytical columns, while the matrix fl owed to waste. Neither chemical pre-treatment nor sample dilution was required. In the optimized separation conditions, the method showed good linearity( R >0.99) in the 0.05 and 50 mg/L concentration range, and satisfactory repeatability(RSD<5%, n =6). The limit of detection for nitrate was 0.02 mg/L. Results showed that the valve switching system was suitable and practical for the determination of trace nitrate in seawater.展开更多
In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The...In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve.展开更多
基金Project (Nos. 50776075 and 50536040) supported by the National Natural Science Foundation of China
文摘In order to overcome the inconvenience of manual bubble counting, a bubble counter based on photoelectric technique aiming for automatically detecting and measuring minute gas leakage of cryogenic valves is proposed. Experiments have been conducted on a self-built apparatus, testing the performance with different gas inlet strategies (bottom gas-inlet strategy and side gas-inlet strategy) and the influence of gas pipe length (0, 1, 2, 4, 6, 8, 10 m) and leakage rate (around 10, 20, 30, 40 bubbles/min) on first bubble time and bubble rate. A buffer of 110 cm3 is inserted between leakage source and gas pipe to simulate the down- stream cavum adjacent to the valve clack. Based on analyzing the experimental data, experiential parameters have also been summarized to guide leakage detection and measurement for engineering applications. A practical system has already been suc- cessfully applied in a cryogenic testing apparatus for cryogenic valves.
基金Supported by the National Special Fund for Major Research Instrumentation Development(No.2012YQ090229)the Instrument Functional Exploitation and Technical Innovation Fund,Chinese Academy of Sciences(No.yg2010072)the Shandong Provincial Technology Development Plan Fund(Nos.2011SJGZ06,2012SJGZ12,2012424012)
文摘An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane desalter was used to reduce the high concentrations of sodium salts in samples. In this method, trace nitrate was eluted from the concentrator column to the analytical columns, while the matrix fl owed to waste. Neither chemical pre-treatment nor sample dilution was required. In the optimized separation conditions, the method showed good linearity( R >0.99) in the 0.05 and 50 mg/L concentration range, and satisfactory repeatability(RSD<5%, n =6). The limit of detection for nitrate was 0.02 mg/L. Results showed that the valve switching system was suitable and practical for the determination of trace nitrate in seawater.
基金Supported by China Coal Research Institute Innovation Item(2007CX06)
文摘In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve.