A novel bonding method using silicate gel as bonding medium is developed.High reflective SiO 2/Si mirrors deposited on silicon substrates by e-beam deposition are bonded to the active layers at a low temperature of ...A novel bonding method using silicate gel as bonding medium is developed.High reflective SiO 2/Si mirrors deposited on silicon substrates by e-beam deposition are bonded to the active layers at a low temperature of 350℃ without any special treatment on bonding surfaces.The reflectivities of the mirrors can be as high as 99 9%.A Si-based narrow band response InGaAs photodetector is successfully fabricated,with a quantum efficiency of 22 6% at the peak wavelength of 1 54μm,and a full width at half maximum of about 27nm.This method has a great potential for industry processes.展开更多
For the question of applying high-pressure water injection to increase gas extraction efficiency by increasing the permeability of water to drive gas action, an independently designed gas desorption experimental measu...For the question of applying high-pressure water injection to increase gas extraction efficiency by increasing the permeability of water to drive gas action, an independently designed gas desorption experimental measuring device was used under the condition of external solution invasion. The law of water effect on gas desorption was obtained after water invasion through experiment for the first time. The results show that water's later invasion not only can make the quantity of gas dcsorp- tion greatly reduced, but also can make gas desorption end early. Therefore, when evaluating the applications of high-pressure water injection to increase gas extraction efficiency, we should take water damaging effects on gas desorption into account.展开更多
A new concept of neutron detector based on Gas Electron Multiplier(GEM) technology is presented in this paper,in which a novel multi-layer high density polyethylene(HDPE) as neutron-to-proton converter is proposed and...A new concept of neutron detector based on Gas Electron Multiplier(GEM) technology is presented in this paper,in which a novel multi-layer high density polyethylene(HDPE) as neutron-to-proton converter is proposed and studied with Geant4 toolkit for fast 14 MeV neutron.Our preliminary results show that the detection efficiency of the detector with 400 converter units is higher than 2.3% and reconstruction accuracy of the incident neutron position is higher than 2.6%.展开更多
文摘A novel bonding method using silicate gel as bonding medium is developed.High reflective SiO 2/Si mirrors deposited on silicon substrates by e-beam deposition are bonded to the active layers at a low temperature of 350℃ without any special treatment on bonding surfaces.The reflectivities of the mirrors can be as high as 99 9%.A Si-based narrow band response InGaAs photodetector is successfully fabricated,with a quantum efficiency of 22 6% at the peak wavelength of 1 54μm,and a full width at half maximum of about 27nm.This method has a great potential for industry processes.
文摘For the question of applying high-pressure water injection to increase gas extraction efficiency by increasing the permeability of water to drive gas action, an independently designed gas desorption experimental measuring device was used under the condition of external solution invasion. The law of water effect on gas desorption was obtained after water invasion through experiment for the first time. The results show that water's later invasion not only can make the quantity of gas dcsorp- tion greatly reduced, but also can make gas desorption end early. Therefore, when evaluating the applications of high-pressure water injection to increase gas extraction efficiency, we should take water damaging effects on gas desorption into account.
基金supported by the National Natural Science Foundation of China (Grant Nos.11075069,11075068,91026021 and 11135002)
文摘A new concept of neutron detector based on Gas Electron Multiplier(GEM) technology is presented in this paper,in which a novel multi-layer high density polyethylene(HDPE) as neutron-to-proton converter is proposed and studied with Geant4 toolkit for fast 14 MeV neutron.Our preliminary results show that the detection efficiency of the detector with 400 converter units is higher than 2.3% and reconstruction accuracy of the incident neutron position is higher than 2.6%.