期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
GUM法和自适应MCM法在海水盐度测量仪器检定装置不确定度评定中的应用分析 被引量:1
1
作者 王朋朋 赵士伟 +1 位作者 刘园园 孟文蓉 《计量学报》 CSCD 北大核心 2020年第S01期183-188,共6页
通过GUM法和自适应蒙特卡洛法(自适应MCM法)分别对海水盐度测量仪器检定装置进行测量不确定度评定,并采用自适应MCM法对GUM法进行了验证,同时设计了4种方案进行了空气浮力项等的影响分析。结果表明,基于自适应MCM法得到的测量不确定度... 通过GUM法和自适应蒙特卡洛法(自适应MCM法)分别对海水盐度测量仪器检定装置进行测量不确定度评定,并采用自适应MCM法对GUM法进行了验证,同时设计了4种方案进行了空气浮力项等的影响分析。结果表明,基于自适应MCM法得到的测量不确定度评定结果与GUM法非常接近,GUM法在各个检测点均通过了验证,但自适应MCM法更为简便准确,为建立军用盐度标准提供一种简便的方法;空气浮力项引起的盐度估计值误差为±0.0003,且引入的不确定度较小;操作者和环境是测量不确定度评定中的重要部分,特别对低盐度检测点的影响较大,这对盐度量值溯源传递会产生一定的影响。 展开更多
关键词 计量学 GUM法 自适应蒙特卡洛法 海水盐度测量仪器检定装置 空气浮力项 测量不确定度
下载PDF
新一代CTD系统
2
作者 布良,NL 陈汉权 《南海研究与开发》 1989年第4期65-71,共7页
关键词 CTD系统 海水电导率 海水仪器
下载PDF
A long-term in situ calibration system for chemistry analysis of seawater
3
作者 Chun-yang TAN Bo JIN +2 位作者 Kang DING William E. SEYFRIED Jr. Ying CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2010年第9期701-708,共8页
An in situ calibration system is a versatile exploration instrument for electrochemical sensors investigating the biochemical properties of the marine environment. The purpose of this paper is to describe the design o... An in situ calibration system is a versatile exploration instrument for electrochemical sensors investigating the biochemical properties of the marine environment. The purpose of this paper is to describe the design of an auto-calibrating system for electrochemical (pH) sensors, which permits two-point in situ calibration, suitable for long-term measurement in deep sea aqueous environments. Holding multiple sensors, the instrument is designed to perform long-term measurements and in situ calibrations at abyssal depth (up to 4000 m). The instrument is composed of a compact fluid control system which is pressure-equilibrated and designed for deep-sea operation. In situ calibration capability plays a key role in the quality and reproducibility of the data. This paper focuses on methods for extending the lifetime of the instrument, considering the fluidics design, mechanical design, and low-power consumption of the electronics controller. The instrument can last 46 d under normal operating conditions, fulfilling the need for long-term operation. Data concerning pH measured during the KNOX18RR cruise (Mid-Atlantic Ridge, July-August, 2008) illustrate the desirable properties of the instrument. Combined with different electrodes (pH, H2, H2S, etc.), it should be of great utility for the study of deep ocean environments, including water column and diffuse-flow hydrothermal fluids. 展开更多
关键词 PH LONG-TERM In situ calibration Flow control Low power
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部