期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
35kV线路接地故障的处理方法 被引量:1
1
作者 薄新全 李壮和 《煤矿机电》 北大核心 2001年第5期37-38,共2页
对35kV线路引发接地故障的原因进行分析 。
关键词 35KV线路 接地故障 解决方法 供电系统 电容 中性点经消弧圈接地
下载PDF
Application of DC component to select fault branch in arc suppression coil grounding system 被引量:2
2
作者 Zhi-Jie WANG Yan-Wen WANG 《Journal of Coal Science & Engineering(China)》 2013年第3期396-401,共6页
When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is... When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system. 展开更多
关键词 DC component arc suppression coil fault line selection transient state
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
3
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation Grounding current detection Zero sequence voltage detection
下载PDF
基于智能一次设备构架的自动化模块变电站设计研究
4
作者 程智余 黄战 于晓蕾 《自动化与仪器仪表》 2024年第4期135-138,143,共5页
随着科学技术与互联网的发展,变电站逐渐趋于智能化和自动化,对传统变电站的升级已是不可逆转的趋势。研究依据国家规定和行业相关要求,基于一次设备对变母线,断路器和主接线等进行规划选型,利用自动化模块技术设计了智能变电站,并对其... 随着科学技术与互联网的发展,变电站逐渐趋于智能化和自动化,对传统变电站的升级已是不可逆转的趋势。研究依据国家规定和行业相关要求,基于一次设备对变母线,断路器和主接线等进行规划选型,利用自动化模块技术设计了智能变电站,并对其进行仿真验证。测试结果表明,自动化模块变电站选择的一次设备绝缘性能良好,且断路器具有较强的断弧能力。自动化模块智能变电站平均故障率为1.78%,传统变电站平均故障率为3.98%,自动化模块智能变电站有效地降低变电站的故障率,提高变电站的安全性。在工程造价方面,自动化模块智能变电站比传统变电站动态投资和静态投资分别节约了567和582万元。以上结果说明基于智能一次设备构架自动化模块设计的变电站故障发生概率较低,安全性较高,在建设变电站领域具备较好的实用性和经济性。 展开更多
关键词 变电站 自动化模块 一次设备 断路器 消弧圈
原文传递
上一页 1 下一页 到第