Valveless piezoelectric pump is widely used in the medical,however,there is a general and difficult problem to be solved:Low vortex and large flow rate are not compatible,resulting in the blood prone to thrombosis dur...Valveless piezoelectric pump is widely used in the medical,however,there is a general and difficult problem to be solved:Low vortex and large flow rate are not compatible,resulting in the blood prone to thrombosis during blood delivery.In this paper,a new valveless piezoelectric(PZT)pump with streamlined flow tubes(streamlined pump)is proposed.The design method and the working principle of the pump are analyzed.The velocity streamlines are simulated,and the results demonstrate that there are no obvious vortexes in the flow tube of the streamlined pump.Five prototype pumps(two cone pumps and three streamlined pumps)are designed and fabricated to perform flow rate and flow resistance experiments.The experimental results illustrate that the maximum flow rate of the streamlined pump is 142 mL/min,which is 179%higher than that of the cone piezoelectric pump,demonstrating that the streamlined pump has a large flow rate performance.This research provides an inspiration for future research on simple structure,low vortex and large flow rate volume-type pumps,and also provides a useful solution for thrombosis preventing.展开更多
The characteristics of the dual bluff body vortex shedding is investigated, and the possibility to use dual bluff body combinations to strengthen the hydrodynamic vibration around the bluff body objects is explored. T...The characteristics of the dual bluff body vortex shedding is investigated, and the possibility to use dual bluff body combinations to strengthen the hydrodynamic vibration around the bluff body objects is explored. The numerical and experimental approaches were utilized to examine the time dependent flow field and the pressure oscillation around the bluff bodies. The numerical data were obtained by the advanced large eddy simulation model. The experiment was conducted on a laboratory scale of Karman vortex flowmeter with 40 mm diameter. It is revealed that the optimized dual bluff body combinations strengthened the hydrodynamic vibration. It was also found that the hydrodynamic vibration with 180° phase difference occurred at the axisymmetric points of circular pipe on the lateral faces of the equilateral triangle-section bluff bodies. Using the dual bluff body configuration and the differential sensing technique, a novel prototype of vortex flowmeter with excellent noise immunity and improved sensibility was developed.展开更多
The Gaussian vortex beam is assumed to be linearly polarized.The analytical expression of the electric field of a linearly polarized Gaussian vortex beam propagating in free space is derived by using the vectorial Ray...The Gaussian vortex beam is assumed to be linearly polarized.The analytical expression of the electric field of a linearly polarized Gaussian vortex beam propagating in free space is derived by using the vectorial Rayleigh-Sommerfeld integral formulae.The propagating magnetic field of the linearly polarized Gaussian vortex beam is presented by taking the curl of the electric field.By employing the electromagnetic field of the linearly polarized Gaussian vortex beam beyond the paraxial approximation,the analytical expression of the angular momentum density of the linearly polarized Gaussian vortex beam is derived.The three components of the angular momentum density of a linearly polarized Gaussian vortex beam are demonstrated in the reference plane.The effects of the linearly polarized angle and the topological charge on the three components of the angular momentum density are investigated.To acquire the more longitudinal angular momentum density requires such an optimal choice that the linearly polarized angle is set to be zero and the topological charge increases.This research is useful to the optical trapping,the optical guiding,and the optical manipulation.展开更多
The grating eddy current displacement sensor (GECDS) for distance or position measurement used in watertight electronic calipers was described. The sensor relies on repetitive variation of inductance against displacem...The grating eddy current displacement sensor (GECDS) for distance or position measurement used in watertight electronic calipers was described. The sensor relies on repetitive variation of inductance against displacement caused by the change of coupling areas between moving coils and static reflectors. The investigations focused on setting up and utilizing a computer model of the 3D eddy current fields and geometry to analyze causes of the production of measurement blind areas, and to investigate effects of the sensor parameters, such as axial gap between coils and reflectors, reflector length and reflector width on characteristics of the sensor. Simulation results indicated that the sensor has the smallest nonlinearity error of 0.15%, which agrees well with the experimental results.展开更多
基金supported by the National Natural Science Foundation of China (No. 51375227)the Introduction of Talent Research Start-up Fund of Nanjing Institute of Technology(No. YKJ201960).
文摘Valveless piezoelectric pump is widely used in the medical,however,there is a general and difficult problem to be solved:Low vortex and large flow rate are not compatible,resulting in the blood prone to thrombosis during blood delivery.In this paper,a new valveless piezoelectric(PZT)pump with streamlined flow tubes(streamlined pump)is proposed.The design method and the working principle of the pump are analyzed.The velocity streamlines are simulated,and the results demonstrate that there are no obvious vortexes in the flow tube of the streamlined pump.Five prototype pumps(two cone pumps and three streamlined pumps)are designed and fabricated to perform flow rate and flow resistance experiments.The experimental results illustrate that the maximum flow rate of the streamlined pump is 142 mL/min,which is 179%higher than that of the cone piezoelectric pump,demonstrating that the streamlined pump has a large flow rate performance.This research provides an inspiration for future research on simple structure,low vortex and large flow rate volume-type pumps,and also provides a useful solution for thrombosis preventing.
基金Supported by the National Natural Science Foundation of China (No. 59835160) and Scientific Research Foundation of State Education Ministry for Returned Overseas Chinese Scholars.
文摘The characteristics of the dual bluff body vortex shedding is investigated, and the possibility to use dual bluff body combinations to strengthen the hydrodynamic vibration around the bluff body objects is explored. The numerical and experimental approaches were utilized to examine the time dependent flow field and the pressure oscillation around the bluff bodies. The numerical data were obtained by the advanced large eddy simulation model. The experiment was conducted on a laboratory scale of Karman vortex flowmeter with 40 mm diameter. It is revealed that the optimized dual bluff body combinations strengthened the hydrodynamic vibration. It was also found that the hydrodynamic vibration with 180° phase difference occurred at the axisymmetric points of circular pipe on the lateral faces of the equilateral triangle-section bluff bodies. Using the dual bluff body configuration and the differential sensing technique, a novel prototype of vortex flowmeter with excellent noise immunity and improved sensibility was developed.
基金supported by the National Natural Science Foundation of China(Grant Nos.61178016 and 10974179)Zhejiang Provincial Natural Science Foundation of China(Grant No.Y1090073)
文摘The Gaussian vortex beam is assumed to be linearly polarized.The analytical expression of the electric field of a linearly polarized Gaussian vortex beam propagating in free space is derived by using the vectorial Rayleigh-Sommerfeld integral formulae.The propagating magnetic field of the linearly polarized Gaussian vortex beam is presented by taking the curl of the electric field.By employing the electromagnetic field of the linearly polarized Gaussian vortex beam beyond the paraxial approximation,the analytical expression of the angular momentum density of the linearly polarized Gaussian vortex beam is derived.The three components of the angular momentum density of a linearly polarized Gaussian vortex beam are demonstrated in the reference plane.The effects of the linearly polarized angle and the topological charge on the three components of the angular momentum density are investigated.To acquire the more longitudinal angular momentum density requires such an optimal choice that the linearly polarized angle is set to be zero and the topological charge increases.This research is useful to the optical trapping,the optical guiding,and the optical manipulation.
文摘The grating eddy current displacement sensor (GECDS) for distance or position measurement used in watertight electronic calipers was described. The sensor relies on repetitive variation of inductance against displacement caused by the change of coupling areas between moving coils and static reflectors. The investigations focused on setting up and utilizing a computer model of the 3D eddy current fields and geometry to analyze causes of the production of measurement blind areas, and to investigate effects of the sensor parameters, such as axial gap between coils and reflectors, reflector length and reflector width on characteristics of the sensor. Simulation results indicated that the sensor has the smallest nonlinearity error of 0.15%, which agrees well with the experimental results.