The FCC unit with addition of various inventories of the FP-DSN type sulfur transfer additive was tested in a commercial scale. The effect of the sulfur transfer additive was analyzed by investigating the indicators r...The FCC unit with addition of various inventories of the FP-DSN type sulfur transfer additive was tested in a commercial scale. The effect of the sulfur transfer additive was analyzed by investigating the indicators related with the regenerator flue gas composition,the dry gas composition before desulfurization,the LPG composition before desulfurization,the acid gas,and the yield of gasoline and diesel. The test results indicated that the sulfur was trans ferred from the feed stream into the dry gas,LPG and acid gas,and the sulfur transfer effect was obvious only when the inventory of sulfur transfer additive exceeded over 2.0% of total FCC catalyst inventory.展开更多
The reaction heat effect analysis for the aromatization process of Liquefied Petroleum Gas (LPG) was completed in this paper. In order to characterize this complex reaction system, one set of independent reactions was...The reaction heat effect analysis for the aromatization process of Liquefied Petroleum Gas (LPG) was completed in this paper. In order to characterize this complex reaction system, one set of independent reactions was determined by means of atomic coefficient matrix method. Based on reaction thermodynamic and stoichiometric knowledge, the heat effect, Gibbs free energy change and equilibrium constant for each independent reaction was calculated for the specified conditions. Under these conditions, based on the initial and final composition data from LPG aromatization experiments, the actual extent of reaction for each independent reaction was determined. Furthermore, the global reaction heat and adiabatic temperature rise of LPG aromatization reaction system could be estimated. This work would provide a theoretical guidance for the design and scale-up of reactor for LPG aromatization process, as well as for the selection of proper operating conditions.展开更多
Exposure to CO (carbon monoxide) during cooking in households using LPG (liquefied petroleum gas), natural gas and charcoal as fuels has been conducted. The study aimed at assessing the indoor air quality in order...Exposure to CO (carbon monoxide) during cooking in households using LPG (liquefied petroleum gas), natural gas and charcoal as fuels has been conducted. The study aimed at assessing the indoor air quality in order to address potential hazards associated with CO. Carbon monoxide concentrations and flame temperature were measured at an interval of 1 min for 1 h using CO and thermometer data loggers respectively. While the CO concentration from LPG and natural gas were found below 26 ppm for 1 h, as recommended by WHO (World Health Organization) standards, the average CO concentration from charcoal exceeded the standard limit. In addition closing the kitchen door during cooking increased the CO concentration from 26-295 ppm to 92-597 ppm. According to WHO, the observed CO concentrations from charcoal stove highlights questionable life support atmosphere. It can therefore be suggested that switching to LPG or natural gas from charcoal will reduce CO exposure to persons during cooking.展开更多
PetroChina has got the preliminary approval from the central government for construction of three LNG terminals in the coastal areas of Jiangsu Province, Hebei Province and Liaoning Province. Reportedly, China's Nati...PetroChina has got the preliminary approval from the central government for construction of three LNG terminals in the coastal areas of Jiangsu Province, Hebei Province and Liaoning Province. Reportedly, China's National Development and Reform Commission (NDRC) has given green light to PetroChina to conduct preliminary work in constructing the three terminals”, a PetroChina senior vice-president recently said at an energy forum in Beijing.展开更多
This study carried out full-scale gas water heater combustion experiments and adopted FDS (fire dynamics simulator) to simulate three scenarios--different balcony environments when using water heater, such as airtig...This study carried out full-scale gas water heater combustion experiments and adopted FDS (fire dynamics simulator) to simulate three scenarios--different balcony environments when using water heater, such as airtight balcony, indoor door with openings and force ventilation to compare with full-scale combustion experiments. According to FDS simulation results, 02, CO and CO2 simulation concentration value correspond with full-scale experimental results. When the indoor O2 concentration was lower than 15%, which causes incomplete combustion, the CO concentration would rise rapidly and even reached above 1,500 ppm, causing death in short time. In addition, when the force ventilation model supplied the water heater with enough air to bum, the indoor CO concentration will keep low and harmless to humans. The study also adopted diverse variables, such as the opening area of window, outdoor wind speed and water heater types, to analyze deeply user's safety regarding gas water heater. In a result, while balcony area is larger than 14 mE, the volume of water heater is below 16 L (33.1 kW), and the indoor window, connecting balcony with room, is closed, if the opening on the outdoor window of the balcony is larger than 0.2 mE, this can ensure the personal security of the indoor space.展开更多
文摘The FCC unit with addition of various inventories of the FP-DSN type sulfur transfer additive was tested in a commercial scale. The effect of the sulfur transfer additive was analyzed by investigating the indicators related with the regenerator flue gas composition,the dry gas composition before desulfurization,the LPG composition before desulfurization,the acid gas,and the yield of gasoline and diesel. The test results indicated that the sulfur was trans ferred from the feed stream into the dry gas,LPG and acid gas,and the sulfur transfer effect was obvious only when the inventory of sulfur transfer additive exceeded over 2.0% of total FCC catalyst inventory.
文摘The reaction heat effect analysis for the aromatization process of Liquefied Petroleum Gas (LPG) was completed in this paper. In order to characterize this complex reaction system, one set of independent reactions was determined by means of atomic coefficient matrix method. Based on reaction thermodynamic and stoichiometric knowledge, the heat effect, Gibbs free energy change and equilibrium constant for each independent reaction was calculated for the specified conditions. Under these conditions, based on the initial and final composition data from LPG aromatization experiments, the actual extent of reaction for each independent reaction was determined. Furthermore, the global reaction heat and adiabatic temperature rise of LPG aromatization reaction system could be estimated. This work would provide a theoretical guidance for the design and scale-up of reactor for LPG aromatization process, as well as for the selection of proper operating conditions.
文摘Exposure to CO (carbon monoxide) during cooking in households using LPG (liquefied petroleum gas), natural gas and charcoal as fuels has been conducted. The study aimed at assessing the indoor air quality in order to address potential hazards associated with CO. Carbon monoxide concentrations and flame temperature were measured at an interval of 1 min for 1 h using CO and thermometer data loggers respectively. While the CO concentration from LPG and natural gas were found below 26 ppm for 1 h, as recommended by WHO (World Health Organization) standards, the average CO concentration from charcoal exceeded the standard limit. In addition closing the kitchen door during cooking increased the CO concentration from 26-295 ppm to 92-597 ppm. According to WHO, the observed CO concentrations from charcoal stove highlights questionable life support atmosphere. It can therefore be suggested that switching to LPG or natural gas from charcoal will reduce CO exposure to persons during cooking.
文摘PetroChina has got the preliminary approval from the central government for construction of three LNG terminals in the coastal areas of Jiangsu Province, Hebei Province and Liaoning Province. Reportedly, China's National Development and Reform Commission (NDRC) has given green light to PetroChina to conduct preliminary work in constructing the three terminals”, a PetroChina senior vice-president recently said at an energy forum in Beijing.
文摘This study carried out full-scale gas water heater combustion experiments and adopted FDS (fire dynamics simulator) to simulate three scenarios--different balcony environments when using water heater, such as airtight balcony, indoor door with openings and force ventilation to compare with full-scale combustion experiments. According to FDS simulation results, 02, CO and CO2 simulation concentration value correspond with full-scale experimental results. When the indoor O2 concentration was lower than 15%, which causes incomplete combustion, the CO concentration would rise rapidly and even reached above 1,500 ppm, causing death in short time. In addition, when the force ventilation model supplied the water heater with enough air to bum, the indoor CO concentration will keep low and harmless to humans. The study also adopted diverse variables, such as the opening area of window, outdoor wind speed and water heater types, to analyze deeply user's safety regarding gas water heater. In a result, while balcony area is larger than 14 mE, the volume of water heater is below 16 L (33.1 kW), and the indoor window, connecting balcony with room, is closed, if the opening on the outdoor window of the balcony is larger than 0.2 mE, this can ensure the personal security of the indoor space.