期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
泥驳液压开体系统技术改造
1
作者 丁华 《中国修船》 北大核心 1999年第6期11-11,26,共2页
通过泥驳液压开体系统的挂钩感应开关传动机构的技术改造, 有效地解决了经常发生的船体开体挂钩打不开的故障, 并且改造后的感应开关维修保养方便、传动机构简单可靠。
关键词 泥驳 传动机构 技术改造 液压开体 疏浚
下载PDF
Quick determination of gas pressure before uncovering coal in cross-cuts and shafts 被引量:22
2
作者 JIANG Cheng-lin WANG Chen LI Xiao-wei CHEN Yu-jia XIE Qing-xue LIU Ying TANG Jun YANG Fei-long WANG Fa-kai DENG Su-hua ZHANG Chao-jie CHENG Song-li LV Shu-wen 《Journal of China University of Mining and Technology》 EI 2008年第4期494-499,共6页
The determination of gas pressure before uncovering coal in cross-cuts and in shafts is one of the important steps in pre- dicting coal and gas outbursts. However, the time spent for testing gas pressure is, at presen... The determination of gas pressure before uncovering coal in cross-cuts and in shafts is one of the important steps in pre- dicting coal and gas outbursts. However, the time spent for testing gas pressure is, at present, very long, seriously affecting the ap- plication of outburst prediction techniques in opening coal seams in cross-cuts and shafts. In order to reduce the time needed in gas pressure tests and to improve the accuracy of tests, we analyzed the process of gas pressure tests and examined the effect of the length of boreholes in coal seams in tests. The result shows that 1) the shorter the borehole, the easier the real pressure value of gas can be obtained and 2) the main factors affecting the time spent in gas pressure tests are the length of the borehole in coal seams, the gas emission time after the borehole has been formed and the quality of the borehole-sealing. The longer the length of the bore- hole, the longer the gas emission time and the larger the pressure-relief circle formed around the borehole, the longer the time needed for pressure tests. By controlling the length of the borehole in a test case in the Huainan mining area, and adopting a quick sealing technique using a sticky liquid method, the sealing quality was clearly improved and the gas emission time as well as the amount of gas discharged greatly decreased. Before the method described, the time required for the gas pressure to increase during the pressure test process, was more than 10 days. With our new method the required time is only 5 hours. In addition, the accuracy of the gas pressure test is greatly improved. 展开更多
关键词 gas pressure sticky liquid sealing quick test cross-cut SHAFT
下载PDF
Factors affecting cerebrospinal fluid opening pressure in patients with spontaneous intracranial hypotension 被引量:2
3
作者 Ling-ling YAO Xing-yue HU 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2017年第7期577-585,共9页
Objective: Spontaneous intracranial hypotension (SIH) is recognized far more commonly than ever before. Though usually characterized by low cerebrospinal fluid (CSF) pressure, some patients with SIH are observed ... Objective: Spontaneous intracranial hypotension (SIH) is recognized far more commonly than ever before. Though usually characterized by low cerebrospinal fluid (CSF) pressure, some patients with SIH are observed to have normal pressure values. In this study, we aimed to confirm the proportion of patients with normal CSF opening pressure (CSF OP) and explore the factors affecting CSF OP in SIH patients. Methods: We retrospectively reviewed 206 consecutive SIH patients and analyzed their clinical and imaging variables (including demographic data, body mass index (BMI), duration of symptoms, and brain imaging findings). Univariate and multiVariate analyses were performed to identify the potential factors affecting CSF OP. Results: In a total of 114 (55.3%) cases the CSF OP was 〈60 mmH2O (1 mmH2O=9.80665 Pa), in 90 (43.7%) cases it was between 60 and 200 mmH2O, and in 2 (1.0%) cases it was 〉200 mmH2O. Univadate analysis showed that the duration of symptoms (P〈0.001), BMI (P〈0.001), and age (P=0.024) were positively correlated with CSF OP. However, multivariate analysis suggested that only the duration of symptoms (P〈0.001) and BMI (P〈0.001) were strongly correlated with CSF OP. A relatively high R2 of 0.681 was obtained for the multivariate model. Conclusions: Our study indicated that in patients without a low CSF OP, a diagnosis of SIH should not be excluded. BMI and the duration of symptoms can influence CSF OP in SIH patients, and other potential factors need further investigation. 展开更多
关键词 Spontaneous intracranial hypotension Low cerebrospinal fluid opening pressure Body mass index Magnetic resonance imaging
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部