Numerical simulation of transient mass transfer to a single dropcontrolled by the internal resistance or by the resistance in bothphases was mathematically formulated and simulated in aboundary-fitted orthogonal coord...Numerical simulation of transient mass transfer to a single dropcontrolled by the internal resistance or by the resistance in bothphases was mathematically formulated and simulated in aboundary-fitted orthogonal coordinate system. The simulated resultson the transient mass transfer dominated by the internal resistanceare in good agreement with the Newman and Kronig-Brink models fordrops with low Reynolds number. When the drop Reynolds number is upto 200, the mass transfer coefficient from numerical simulation isvery low as compared with The Handlos-Baron model.展开更多
Characteristics of thermal-hydraulic interaction of LBE (45w%Pb-55w%Bi) and lead with subcooled water in pool water were investigated experimentally. Two kinds of interaction zones (deformation and fragmentation) ...Characteristics of thermal-hydraulic interaction of LBE (45w%Pb-55w%Bi) and lead with subcooled water in pool water were investigated experimentally. Two kinds of interaction zones (deformation and fragmentation) and three kinds of interaction zones (solidification, deformation and fragmentation) were observed during LBE droplet/water interaction and lead droplet/water interaction, respectively. The fragmentation zone (FZ) could be identified exactly by two border lines: spontaneous nucleation temperature and minimum film boiling temperature. Within fragmentation zone, 10% to 35% tiny debris (diameter 〈 1 mm) of LBE and 5 to 8 kPa peak pressure generated with increasing the LBE temperature and no effect with increasing the subcooling of water. Only 2%-4% tiny debris (diameter 〈 1 mm) of lead and 2 kPa peak pressure generated regardless of lead and water temperature.展开更多
The contact angle is one of important parameters to simulate droplet spreading and impingement phenomena on the surface. In the most numerical research, it is assumed constant value and it is implemented as boundary c...The contact angle is one of important parameters to simulate droplet spreading and impingement phenomena on the surface. In the most numerical research, it is assumed constant value and it is implemented as boundary condition. However, contact angle is changed according to contact line velocity and time. Hence, for accurate simulation, dynamic contact angle which has various values as time elapsed is adopted. In the present study, the numerical analysis is performed on the droplet spreading phenomena considering dynamic contact angle function which is obtained from single droplet spreading experiment on the flat and bare surface. The CIP (cubic interpolated pseudo-particle) method by Yabe is used for analysis of interface between liquid and gas phases. The numerical results considering contact angle function which newly modeled as time and contact angle are compared with numerical results considering Hoffman's function and experimental data for range of Weber number which are 4.427 and 11.334. In contrast of numerical result considering Hoffman's function, the numerical result shows good agreement with experimental data as time elapsed in contact angle evolution, deformation of droplet spreading radius and height. Indeed, overall, the results display the increasing maximum spreading radius and the decreasing height as Weber numbers increased.展开更多
Recently, much attention has been paid to investigate the latent heat storage system. Using of ice heat storage system brings an equalization of electric power demand, because it will solved the electric -power-demand...Recently, much attention has been paid to investigate the latent heat storage system. Using of ice heat storage system brings an equalization of electric power demand, because it will solved the electric -power-demand-concentration on day-time of summer by the air conditioning. The flowable latent heat storage material, Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enable to transport the latent heat in a pipe. The flowable latent heat storage material can realize the pipe size reduction and system efficiency improvement. Supercooling phenomenon of the dispersed latent heat storage material in continuous phase brings the obstruction of latent heat storage. The latent heat storage rates of dispersed water drops in W/O (Water/Oil) emulsion are investigated experimentally in this study. The water drops in emulsion has the diameter within 3 ~ 25μm, the averaged water drop diameter is 7.3μm and the standard deviation is 2.9μm. The direct contact heat exchange method is chosen as the phase change rate evaluation of water drops in W/O emulsion. The supercooled temperature and the cooling rate are set as parameters of this study. The evaluation is performed by comparison between the results of this study and the past research. The obtained experimental result is shown that the 35K or more degree from melting point brings 100% latent heat storage rate of W/O emulsion. It was clarified that the supercooling rate of dispersed water particles in emulsion shows the larger value than that of the bulk water.展开更多
基金Supported by the National Natural Science Foundation of China (No. 29792074, No. 29836130} and SINOPEC.
文摘Numerical simulation of transient mass transfer to a single dropcontrolled by the internal resistance or by the resistance in bothphases was mathematically formulated and simulated in aboundary-fitted orthogonal coordinate system. The simulated resultson the transient mass transfer dominated by the internal resistanceare in good agreement with the Newman and Kronig-Brink models fordrops with low Reynolds number. When the drop Reynolds number is upto 200, the mass transfer coefficient from numerical simulation isvery low as compared with The Handlos-Baron model.
文摘Characteristics of thermal-hydraulic interaction of LBE (45w%Pb-55w%Bi) and lead with subcooled water in pool water were investigated experimentally. Two kinds of interaction zones (deformation and fragmentation) and three kinds of interaction zones (solidification, deformation and fragmentation) were observed during LBE droplet/water interaction and lead droplet/water interaction, respectively. The fragmentation zone (FZ) could be identified exactly by two border lines: spontaneous nucleation temperature and minimum film boiling temperature. Within fragmentation zone, 10% to 35% tiny debris (diameter 〈 1 mm) of LBE and 5 to 8 kPa peak pressure generated with increasing the LBE temperature and no effect with increasing the subcooling of water. Only 2%-4% tiny debris (diameter 〈 1 mm) of lead and 2 kPa peak pressure generated regardless of lead and water temperature.
文摘The contact angle is one of important parameters to simulate droplet spreading and impingement phenomena on the surface. In the most numerical research, it is assumed constant value and it is implemented as boundary condition. However, contact angle is changed according to contact line velocity and time. Hence, for accurate simulation, dynamic contact angle which has various values as time elapsed is adopted. In the present study, the numerical analysis is performed on the droplet spreading phenomena considering dynamic contact angle function which is obtained from single droplet spreading experiment on the flat and bare surface. The CIP (cubic interpolated pseudo-particle) method by Yabe is used for analysis of interface between liquid and gas phases. The numerical results considering contact angle function which newly modeled as time and contact angle are compared with numerical results considering Hoffman's function and experimental data for range of Weber number which are 4.427 and 11.334. In contrast of numerical result considering Hoffman's function, the numerical result shows good agreement with experimental data as time elapsed in contact angle evolution, deformation of droplet spreading radius and height. Indeed, overall, the results display the increasing maximum spreading radius and the decreasing height as Weber numbers increased.
文摘Recently, much attention has been paid to investigate the latent heat storage system. Using of ice heat storage system brings an equalization of electric power demand, because it will solved the electric -power-demand-concentration on day-time of summer by the air conditioning. The flowable latent heat storage material, Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enable to transport the latent heat in a pipe. The flowable latent heat storage material can realize the pipe size reduction and system efficiency improvement. Supercooling phenomenon of the dispersed latent heat storage material in continuous phase brings the obstruction of latent heat storage. The latent heat storage rates of dispersed water drops in W/O (Water/Oil) emulsion are investigated experimentally in this study. The water drops in emulsion has the diameter within 3 ~ 25μm, the averaged water drop diameter is 7.3μm and the standard deviation is 2.9μm. The direct contact heat exchange method is chosen as the phase change rate evaluation of water drops in W/O emulsion. The supercooled temperature and the cooling rate are set as parameters of this study. The evaluation is performed by comparison between the results of this study and the past research. The obtained experimental result is shown that the 35K or more degree from melting point brings 100% latent heat storage rate of W/O emulsion. It was clarified that the supercooling rate of dispersed water particles in emulsion shows the larger value than that of the bulk water.