期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
混水平列扩充设计的混偏差的下界 被引量:1
1
作者 雷轶菊 欧祖军 赵国喜 《数学物理学报(A辑)》 CSCD 北大核心 2021年第3期882-891,共10页
扩充设计作为一种新型的试验设计,近年来受到学者越来越广泛地关注.扩充设计包括初始设计与跟随设计两部分.在许多跟随设计中,在跟随阶段可以加入一些另外的2-水平或3-水平因子,因为它们在初始阶段可能被忽略但又十分重要.该文在均匀性... 扩充设计作为一种新型的试验设计,近年来受到学者越来越广泛地关注.扩充设计包括初始设计与跟随设计两部分.在许多跟随设计中,在跟随阶段可以加入一些另外的2-水平或3-水平因子,因为它们在初始阶段可能被忽略但又十分重要.该文在均匀性准则下,给出了列扩充设计在混偏差下的解析表达式及相应的下界,列举了混偏差意义下的混水平列扩充近似均匀设计. 展开更多
关键词 跟随设计 混偏差 下界
下载PDF
麻棉混纺纱混比偏差的成因及控制措施
2
作者 叶汶祥 张一鸣 +1 位作者 俞春兰 吴健恒 《福建轻纺》 2001年第5期7-13,共7页
以纺制 R/C55/4 530 S为例 ,论述了原料、设备、工艺、车间管理、车间环境条件等对麻棉纱混比偏差的影响 。
关键词 麻棉纺纱 偏差 成因 质量控制
下载PDF
Effects of blade rotation angle deviations on mixed-flow pump hydraulic performance 被引量:1
3
作者 BING Hao CAO ShuLiang 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第7期1372-1382,共11页
By model test and numerical simulation, this paper analyzed the effects of different blades with varying rotation angle deviations on the hydraulic performance of a mixed-flow pump. It was found that when some blades ... By model test and numerical simulation, this paper analyzed the effects of different blades with varying rotation angle deviations on the hydraulic performance of a mixed-flow pump. It was found that when some blades had rotation angle deviations, the hydraulic performance curves of the mixed-flow pump would move. With a positive deviation, the curves moved towards the large flow rate; with a negative deviation, the curves moved towards the small flow rate. When some blades had rotation angle deviations, the symmetry and uniformity of the pressure distribution inside the mixed-flow pump flow passage both decreased; the larger the deviation, the greater the decrease. When a single blade had a large rotation angle deviation, a rather clear low pressure area was formed, lowering the cavitation performance. When two adjacent blades changed simultaneously, under the small flow rate condition, adverse pressure gradient and flow separation occurred in the flow field, and a hump appeared in the head curve and the operation stability of the mixed-flow pump dropped significantly. Near the best efficiency point(BEP), the simultaneous change of two alternate blades produced a more significant change of pressure in the flow passage, with an even larger area. Compared to the effect of two adjacent blades, two alternate blades, when changed simultaneously, made the mixed-flow pump slightly less efficient, but with a flatter efficiency curve and relatively wider high efficiency area. By fitting the test results, a functional relation among the BEP of the mixed-flow pump QBEP, the number of deviated blades N, and blade rotation angle deviation α was established, thus realizing an effective prediction of the BEP of the mixed-flow pump when blade rotation angles have deviations. 展开更多
关键词 mixed-flow pump blade rotation angle hydraulic performance model test numerical simulation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部