For those refineries which have to deal with different types of crude oil, blending is an attractive solution to obtain a quality feedstock. In this paper, a novel scheduling strategy is proposed for a practical crude...For those refineries which have to deal with different types of crude oil, blending is an attractive solution to obtain a quality feedstock. In this paper, a novel scheduling strategy is proposed for a practical crude oil blending process. The objective is to keep the property of feedstock, mainly described by the true boiling point (TBP) data, consistent and suitable. Firstly, the mathematical model is established. Then, a heuristically initialized hybrid iterative (HIHI) algorithm based on a two-level optimization structure, in which tabu search (TS) and differential evolution (DE) are used for upper-level and lower-level optimization, respectively, is proposed to get the model solution. Finally, the effectiveness and efficiency of the scheduling strategy is validated via real data from a certain refinery.展开更多
Based on the log-linear virtual age process, an imperfect preventive maintenance policy for numerical control(NC)machine tools with random maintenance quality is proposed. The proposed model is a combination of the Ki...Based on the log-linear virtual age process, an imperfect preventive maintenance policy for numerical control(NC)machine tools with random maintenance quality is proposed. The proposed model is a combination of the Kijima type virtual age model and the failure intensity adjustment model. Maintenance intervals of the proposed hybrid model are derived when the failure intensity increase factor and the restoration factor are both random variables with uniform distribution. The optimal maintenance policy in infinite time horizon is presented. A numerical example is given when the failures of NC machine tools are described by the log-linear process. Finally, a discussion is presented to show how the optimal results depend on the different cost parameters.展开更多
According to the complex nonlinear relationship between gas emission and its effect factors, and the shortcomings that basic colony algorithm is slow, prone to early maturity and stagnation during the search, we intro...According to the complex nonlinear relationship between gas emission and its effect factors, and the shortcomings that basic colony algorithm is slow, prone to early maturity and stagnation during the search, we introduced a hybrid optimization strategy into a max-rain ant colony algorithm, then use this improved ant colony algorithm to estimate the scope of RBF network parameters. According to the amount of pheromone of discrete points, the authors obtained from the interval of net- work parameters, ants optimize network parameters. Finally, local spatial expansion is introduced to get further optimization of the network. Therefore, we obtain a better time efficiency and solution efficiency optimization model called hybrid improved max-min ant system (H1-MMAS). Simulation experiments, using these theory to predict the gas emission from the working face, show that the proposed method have high prediction feasibility and it is an effective method to predict gas emission.展开更多
This paper investigates on the base stations(BSs) sleeping control and energy saving in wireless network. The objective is to find the sleeping control and energy saving configuration between total power consumption a...This paper investigates on the base stations(BSs) sleeping control and energy saving in wireless network. The objective is to find the sleeping control and energy saving configuration between total power consumption and average video's quality. On the Software Defined Network(SDN) access network architecture, a type of sleeping control and active BSs' optimal transmitting time strategy is considered, the BS sleeps when there is no active users, and wakes up after a period of vacation time. In this paper, we study the active users grouping strategy, In order to spare more BSs into sleeping mode. Then this paper proposes an active BS transmitting time optimal strategy according to the users' Qo S. In the proposed strategy, the active BSs' transmitting time is minimized in order to save energy. This paper employs the mixed integer-programming model to present this optimization problem. Then we utilized a novel algorithm to save the energy in access networks and also meet the Qo S requirements. Both the analytical and simulation results show that the algorithm can effectively save energy in the access network BSs.展开更多
Mixed redundancy strategies are generally used in cloud-based systems,with different node switch mechanisms from traditional fault-tolerant strategies.Existing studies often concentrate on optimizing a single strategy...Mixed redundancy strategies are generally used in cloud-based systems,with different node switch mechanisms from traditional fault-tolerant strategies.Existing studies often concentrate on optimizing a single strategy in cloud computing environment and ignore the impact of mixed redundancy strategies.Therefore,a model is proposed to evaluate and optimize the reliability and performance of cloud-based degraded systems subject to a mixed active and cold standby redundancy strategy.In this strategy,node switching is triggered by a continual monitoring and detection mechanism when active nodes fail.To evaluate the transient availability and the expected job completion rate of systems with such kind of strategy,a continuous-time Markov chain model is built on the state transition process and a numerical method is used to solve the model.To choose the optimal redundancy for the mixed strategy under system constraints,a greedy search algorithm is proposed after sensitivity analysis.Illustrative examples were presented to explain the process of calculating the transient probability of each system state and in turn,the availability and performance of the whole system.It was shown that the near-optimal redundancy solution could be obtained using the optimizationmethod.The comparison with optimization of the traditional mixed redundancy strategy proved that the system behavior was different using different kinds of mixed strategies and less redundancy was assigned for the new type of mixed strategy under the same system constraint.展开更多
This paper presents a control strategy of a hybrid fuel cell/battery distributed generation (HDG) system in distribution systems. The overall structure of the HDG system is given, dynamic models for the solid oxide fu...This paper presents a control strategy of a hybrid fuel cell/battery distributed generation (HDG) system in distribution systems. The overall structure of the HDG system is given, dynamic models for the solid oxide fuel cell (SOFC) power plant, battery bank and its power electronic interfacing are briefly described, and controller design methodologies for the power conditioning units and fuel cell to control the power flow from the hybrid power plant to the utility grid are presented. To distribute the power between the fuel cell power plant and the battery energy storage, a neuro-fuzzy controller has been developed. Also, for controlling the active and reactive power independently in distribution systems, the current control strategy based on two fuzzy logic controllers has been presented. A Matlab/Simulink simulation model is developed for the HDG system by combining the individual component models and their controllers. Simulation results show the overall system performance including load-following and power management of the HDG system.展开更多
基金Supported by the National High Technology Research and Development Program of China (2007AA04Z193) the National Natural Science Foundation of China (60974008 60704032)
文摘For those refineries which have to deal with different types of crude oil, blending is an attractive solution to obtain a quality feedstock. In this paper, a novel scheduling strategy is proposed for a practical crude oil blending process. The objective is to keep the property of feedstock, mainly described by the true boiling point (TBP) data, consistent and suitable. Firstly, the mathematical model is established. Then, a heuristically initialized hybrid iterative (HIHI) algorithm based on a two-level optimization structure, in which tabu search (TS) and differential evolution (DE) are used for upper-level and lower-level optimization, respectively, is proposed to get the model solution. Finally, the effectiveness and efficiency of the scheduling strategy is validated via real data from a certain refinery.
基金Project(51465034)supported by the National Natural Science Foundation of China
文摘Based on the log-linear virtual age process, an imperfect preventive maintenance policy for numerical control(NC)machine tools with random maintenance quality is proposed. The proposed model is a combination of the Kijima type virtual age model and the failure intensity adjustment model. Maintenance intervals of the proposed hybrid model are derived when the failure intensity increase factor and the restoration factor are both random variables with uniform distribution. The optimal maintenance policy in infinite time horizon is presented. A numerical example is given when the failures of NC machine tools are described by the log-linear process. Finally, a discussion is presented to show how the optimal results depend on the different cost parameters.
基金Supported by the National Natural Science Foundation (70971059) the Liaoning Provincial Programs lbr Science and Technology Development (2011229011)
文摘According to the complex nonlinear relationship between gas emission and its effect factors, and the shortcomings that basic colony algorithm is slow, prone to early maturity and stagnation during the search, we introduced a hybrid optimization strategy into a max-rain ant colony algorithm, then use this improved ant colony algorithm to estimate the scope of RBF network parameters. According to the amount of pheromone of discrete points, the authors obtained from the interval of net- work parameters, ants optimize network parameters. Finally, local spatial expansion is introduced to get further optimization of the network. Therefore, we obtain a better time efficiency and solution efficiency optimization model called hybrid improved max-min ant system (H1-MMAS). Simulation experiments, using these theory to predict the gas emission from the working face, show that the proposed method have high prediction feasibility and it is an effective method to predict gas emission.
基金supported by the National High-Tech R&D Program (863 Program2015AA01A705)in part by Beijing Municipal Commission of Education (The City's Vehicle Sensing Grid Construction Based on Public Transportation Network)
文摘This paper investigates on the base stations(BSs) sleeping control and energy saving in wireless network. The objective is to find the sleeping control and energy saving configuration between total power consumption and average video's quality. On the Software Defined Network(SDN) access network architecture, a type of sleeping control and active BSs' optimal transmitting time strategy is considered, the BS sleeps when there is no active users, and wakes up after a period of vacation time. In this paper, we study the active users grouping strategy, In order to spare more BSs into sleeping mode. Then this paper proposes an active BS transmitting time optimal strategy according to the users' Qo S. In the proposed strategy, the active BSs' transmitting time is minimized in order to save energy. This paper employs the mixed integer-programming model to present this optimization problem. Then we utilized a novel algorithm to save the energy in access networks and also meet the Qo S requirements. Both the analytical and simulation results show that the algorithm can effectively save energy in the access network BSs.
基金supported by the National Natural Science Foundation of China(Grant No.61309005)the Basic and Frontier Research Program of Chongqing(Grant No.cstc2014jcyj A40015)
文摘Mixed redundancy strategies are generally used in cloud-based systems,with different node switch mechanisms from traditional fault-tolerant strategies.Existing studies often concentrate on optimizing a single strategy in cloud computing environment and ignore the impact of mixed redundancy strategies.Therefore,a model is proposed to evaluate and optimize the reliability and performance of cloud-based degraded systems subject to a mixed active and cold standby redundancy strategy.In this strategy,node switching is triggered by a continual monitoring and detection mechanism when active nodes fail.To evaluate the transient availability and the expected job completion rate of systems with such kind of strategy,a continuous-time Markov chain model is built on the state transition process and a numerical method is used to solve the model.To choose the optimal redundancy for the mixed strategy under system constraints,a greedy search algorithm is proposed after sensitivity analysis.Illustrative examples were presented to explain the process of calculating the transient probability of each system state and in turn,the availability and performance of the whole system.It was shown that the near-optimal redundancy solution could be obtained using the optimizationmethod.The comparison with optimization of the traditional mixed redundancy strategy proved that the system behavior was different using different kinds of mixed strategies and less redundancy was assigned for the new type of mixed strategy under the same system constraint.
文摘This paper presents a control strategy of a hybrid fuel cell/battery distributed generation (HDG) system in distribution systems. The overall structure of the HDG system is given, dynamic models for the solid oxide fuel cell (SOFC) power plant, battery bank and its power electronic interfacing are briefly described, and controller design methodologies for the power conditioning units and fuel cell to control the power flow from the hybrid power plant to the utility grid are presented. To distribute the power between the fuel cell power plant and the battery energy storage, a neuro-fuzzy controller has been developed. Also, for controlling the active and reactive power independently in distribution systems, the current control strategy based on two fuzzy logic controllers has been presented. A Matlab/Simulink simulation model is developed for the HDG system by combining the individual component models and their controllers. Simulation results show the overall system performance including load-following and power management of the HDG system.