The traditional ground direct current method is not suitable for leakage detection of underground diaphragm walls in foundation pits because of its low accuracy and poor anti-noise ability.Here,we propose a joint surf...The traditional ground direct current method is not suitable for leakage detection of underground diaphragm walls in foundation pits because of its low accuracy and poor anti-noise ability.Here,we propose a joint surface-borehole observation device for leakage electric fi eld detection to achieve rapid measurement of the electric fi eld distribution characteristics at ground level in the foundation pit,thus enabling rapid localization of leakage points.We first establish the mechanism and basic equation of the leakage electric field response by combining the electric field formed by electrokinetic effect(EK)and the stable electric fi eld formed by conduction current in a combined leakage channel.Then,the fi nite–infi nite element coupling method is used to solve the electric fi eld equation to simulate the responses of a three-dimensional foundation pit leakage model.Furthermore,we conduct numerical simulations of diff erent pit models to investigate the infl uencing factors of the detection device and response characteristics of the change in the properties of the leakage channel.The results demonstrate that the proposed joint surface-borehole observation device can effi ciently reveal anomalous potential caused by leakage,and the amplitude of the electric fi eld generated by EK can eff ectively strengthen the leakage electric fi eld signal at the leakage,thus improving detection accuracy and effi ciency.展开更多
This work is focused on the theoretical investigation of internal leakage of a newly developed pi lotscale fluid switcherenergy recovery device (FSERD) for reverse osmosis (RO) system. For the purpose of in creasi...This work is focused on the theoretical investigation of internal leakage of a newly developed pi lotscale fluid switcherenergy recovery device (FSERD) for reverse osmosis (RO) system. For the purpose of in creasing FSERD efficiency and reducing the operating cost of RO, it is required to control the internal leakage in a low level. In this work, the internal leakage rates at different leakage gaps and retentate brine pressures are investigated by computational fluid dynamics (CFD) method and validating experiments. It is found that the internal leak age has a linear relationship with the retentate brine pressure and a polynomial relationship with the scale of leakage gap. The results of the present work imply that low internal leakage and high retentate brine pressure bring benefits to achieve high FSRD efficiency.展开更多
基金partially supported by the National Natural Science Foundation of China (Nos. 41864004 and 41674077)Jiangxi Provincial Academic Leaders (Youth) Training Program (No. 20204BCJL23058)Open Fund from Engineering Research Center for Seismic Disaster Prevention and Engineering Geological Disaster Detection of Jiangxi Province (SDGD202102)。
文摘The traditional ground direct current method is not suitable for leakage detection of underground diaphragm walls in foundation pits because of its low accuracy and poor anti-noise ability.Here,we propose a joint surface-borehole observation device for leakage electric fi eld detection to achieve rapid measurement of the electric fi eld distribution characteristics at ground level in the foundation pit,thus enabling rapid localization of leakage points.We first establish the mechanism and basic equation of the leakage electric field response by combining the electric field formed by electrokinetic effect(EK)and the stable electric fi eld formed by conduction current in a combined leakage channel.Then,the fi nite–infi nite element coupling method is used to solve the electric fi eld equation to simulate the responses of a three-dimensional foundation pit leakage model.Furthermore,we conduct numerical simulations of diff erent pit models to investigate the infl uencing factors of the detection device and response characteristics of the change in the properties of the leakage channel.The results demonstrate that the proposed joint surface-borehole observation device can effi ciently reveal anomalous potential caused by leakage,and the amplitude of the electric fi eld generated by EK can eff ectively strengthen the leakage electric fi eld signal at the leakage,thus improving detection accuracy and effi ciency.
基金Supported by the Research and Development Programs of Tianjin(10JCYBJC04700,10ZCKFSH02100)
文摘This work is focused on the theoretical investigation of internal leakage of a newly developed pi lotscale fluid switcherenergy recovery device (FSERD) for reverse osmosis (RO) system. For the purpose of in creasing FSERD efficiency and reducing the operating cost of RO, it is required to control the internal leakage in a low level. In this work, the internal leakage rates at different leakage gaps and retentate brine pressures are investigated by computational fluid dynamics (CFD) method and validating experiments. It is found that the internal leak age has a linear relationship with the retentate brine pressure and a polynomial relationship with the scale of leakage gap. The results of the present work imply that low internal leakage and high retentate brine pressure bring benefits to achieve high FSRD efficiency.