The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field...The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.展开更多
Mg ion-exchanged samples were prepared with acid-washed Shengli lignite.The chemical composition of the ash of the raw sample was determined by X-ray fluorescence.The equilibrium adsorption water contents of samples w...Mg ion-exchanged samples were prepared with acid-washed Shengli lignite.The chemical composition of the ash of the raw sample was determined by X-ray fluorescence.The equilibrium adsorption water contents of samples were determined in a range of relative humidity.The ion-exchange process was characterized by FT-IR,ash content,and p H value.A possible mechanism is proposed for equilibrium adsorption water of ion-exchanged samples at different humidities.The extent of ion-exchange reaction between Mg2+and lignite is controlled by the concentration of Mg2+in Mg SO4solution.The effect of Mg2+on equilibrium adsorption water content varies with relative humidity and content of Mg2+.The factor that controls equilibrium adsorption water content at low relative humidity is water interactions with sorption sites,which are Mg2+–carboxyl group complex.At middle relative humidity capillary force between Mg2+–water clusters Mg+(H2O)nand capillary is more important.At high relative humidity,free water–free water interactions are more significant.展开更多
The study was performed to determine whether the srum concentrations of IL (interleukin)-6 are elevated in patients with RA (rheumatoid arthritis) and to investigate the relationship between IL-6 levels and iron s...The study was performed to determine whether the srum concentrations of IL (interleukin)-6 are elevated in patients with RA (rheumatoid arthritis) and to investigate the relationship between IL-6 levels and iron status in RA patients. 95 serum samples were obtained, 70 of them from patients with RA who had visited the department of Rheumatology at Al-Sadder medical city in Najaf governorate (Iraq) and 25 age and sex-matched healthy controls. The authors assessed the clinical parameters of the disease, including ESR (erythrocyte sedimentation rate), CRP (C-reactive protein), and RF (rheumatoid factor). Serum levels of iron and TIBC (total iron binding capacity) were measured spectrophotometrically, while TS% (transferrin saturation percentage) and transferrin concentration were calculated mathematically. Serum concentrations of IL-6 (interleukin-6) and ferritin were measured using an ELISA (enzyme-linked immunosorbent assay). The results of serum concentration of IL-6 (interleukin-6) and ferritin were significantly elevated (P 〈 0.0001) in patients with RA compared to those of healthy controls. On the other hand, serum concentrations of iron, TIBC (total iron binding capacity), TS% (transferrin saturation percentage) and transferrin concentration were significantly decreased in patients with RA compared with those of healthy controls. These findings suggest that anemia is the most frequent observations in patients with RA and mostly associative with increasing level of interleukin-6.展开更多
Time domain reflectometry (TDR) is a highly accurate and automatic method for determination of porous media water content and electrical conductivity. This paper focuses on the basic principle of TDR technology and it...Time domain reflectometry (TDR) is a highly accurate and automatic method for determination of porous media water content and electrical conductivity. This paper focuses on the basic principle of TDR technology and its application in Caijiachuan watershed, the Loess Plateau, China, the composition and structure of a set of TDR-TRIME. The installation, measurement and calibration of TRJME-TDR in the Loess Plateau has been introduced. The factors that can influence the veracity of the measurement by TDR have also been analyzed in the article.展开更多
基金the National High Technology Research and Development Program of China(2006AA04Z167,2007AA04Z180)
文摘The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.
基金Supported by the National Basic Research Program of China(2012CB214900)the National Natural Science Foundation of China(51274197)+1 种基金the 111 Project(B12030)the Fundamental Research Funds for the Central Universities(2014XT05)
文摘Mg ion-exchanged samples were prepared with acid-washed Shengli lignite.The chemical composition of the ash of the raw sample was determined by X-ray fluorescence.The equilibrium adsorption water contents of samples were determined in a range of relative humidity.The ion-exchange process was characterized by FT-IR,ash content,and p H value.A possible mechanism is proposed for equilibrium adsorption water of ion-exchanged samples at different humidities.The extent of ion-exchange reaction between Mg2+and lignite is controlled by the concentration of Mg2+in Mg SO4solution.The effect of Mg2+on equilibrium adsorption water content varies with relative humidity and content of Mg2+.The factor that controls equilibrium adsorption water content at low relative humidity is water interactions with sorption sites,which are Mg2+–carboxyl group complex.At middle relative humidity capillary force between Mg2+–water clusters Mg+(H2O)nand capillary is more important.At high relative humidity,free water–free water interactions are more significant.
文摘The study was performed to determine whether the srum concentrations of IL (interleukin)-6 are elevated in patients with RA (rheumatoid arthritis) and to investigate the relationship between IL-6 levels and iron status in RA patients. 95 serum samples were obtained, 70 of them from patients with RA who had visited the department of Rheumatology at Al-Sadder medical city in Najaf governorate (Iraq) and 25 age and sex-matched healthy controls. The authors assessed the clinical parameters of the disease, including ESR (erythrocyte sedimentation rate), CRP (C-reactive protein), and RF (rheumatoid factor). Serum levels of iron and TIBC (total iron binding capacity) were measured spectrophotometrically, while TS% (transferrin saturation percentage) and transferrin concentration were calculated mathematically. Serum concentrations of IL-6 (interleukin-6) and ferritin were measured using an ELISA (enzyme-linked immunosorbent assay). The results of serum concentration of IL-6 (interleukin-6) and ferritin were significantly elevated (P 〈 0.0001) in patients with RA compared to those of healthy controls. On the other hand, serum concentrations of iron, TIBC (total iron binding capacity), TS% (transferrin saturation percentage) and transferrin concentration were significantly decreased in patients with RA compared with those of healthy controls. These findings suggest that anemia is the most frequent observations in patients with RA and mostly associative with increasing level of interleukin-6.
文摘Time domain reflectometry (TDR) is a highly accurate and automatic method for determination of porous media water content and electrical conductivity. This paper focuses on the basic principle of TDR technology and its application in Caijiachuan watershed, the Loess Plateau, China, the composition and structure of a set of TDR-TRIME. The installation, measurement and calibration of TRJME-TDR in the Loess Plateau has been introduced. The factors that can influence the veracity of the measurement by TDR have also been analyzed in the article.