Ion chromatography (IC) is a suitable analytical method for the determination of anions. As analytical methods for the halogen compounds in flue gas, those of bromine compound, fluorine compound, chlorine (Cl2) an...Ion chromatography (IC) is a suitable analytical method for the determination of anions. As analytical methods for the halogen compounds in flue gas, those of bromine compound, fluorine compound, chlorine (Cl2) and hydrogen chloride (HCI) are listed in JIS. However, IC has not been adopted in JIS except for HCI and C12. Because the carbon dioxide in flue gas is absorbed in a 0.1 M sodium hydroxide solution as an absorber, it is interfered with the measurement of F^- and Cl^- ions. This paper describes the development of the pretreatment equipment for the flue gas analysis by IC, and its applications to real flue gas analysis. The F^-, Cl^-, Br^- and SO4^2- in the absorbing solution can be clearly separated by IC using the pretreatment equipment. The halogen compounds and sulfur oxides in flue gas can be simultaneously determined by IC.展开更多
We previously isolated a natural product, namely guaiazulene-2,9-dione showing strong antibacterial activity against Vibrio anguillarum, from a gorgonian Muriceides collaris collected in South China Sea. In this exper...We previously isolated a natural product, namely guaiazulene-2,9-dione showing strong antibacterial activity against Vibrio anguillarum, from a gorgonian Muriceides collaris collected in South China Sea. In this experiment, guaiazulene-2,9-dione was quantitatively synthesized with an optimized one-step bromine oxidation method using guaiazulene as the raw material. The key reaction condition including reaction time and temperature, drop rate of bromine, concentration of aqueous THF solution, respective molar ratio of guaiazulene to bromine and acetic acid, and concentration of guaiazulene in aqueous THF solution, were investigated individually at five levels each for optimization. Combined with the verification test to show the absolute yield of each optimization step, the final optimal condition was determined as: when a solution of 0.025 mmol m L-1 guaiazulene in 80% aqueous THF was treated with four volumes of bromine at a drop rate of 0.1 m L min-1 and four volumes of acetic acid at-5℃ for three hours, the yield of guaiazulene-2,9-dione was 23.72%. This was the first report concerning optimized one-step synthesis to provide a convenient method for the large preparation of guaiazulene-2,9-dione.展开更多
文摘Ion chromatography (IC) is a suitable analytical method for the determination of anions. As analytical methods for the halogen compounds in flue gas, those of bromine compound, fluorine compound, chlorine (Cl2) and hydrogen chloride (HCI) are listed in JIS. However, IC has not been adopted in JIS except for HCI and C12. Because the carbon dioxide in flue gas is absorbed in a 0.1 M sodium hydroxide solution as an absorber, it is interfered with the measurement of F^- and Cl^- ions. This paper describes the development of the pretreatment equipment for the flue gas analysis by IC, and its applications to real flue gas analysis. The F^-, Cl^-, Br^- and SO4^2- in the absorbing solution can be clearly separated by IC using the pretreatment equipment. The halogen compounds and sulfur oxides in flue gas can be simultaneously determined by IC.
基金supported by National Natural Science Foundation of China (No. 21102136)Changjiang Scholars and Innovative Research Team in University (PCSIRT,No. IRT0944)
文摘We previously isolated a natural product, namely guaiazulene-2,9-dione showing strong antibacterial activity against Vibrio anguillarum, from a gorgonian Muriceides collaris collected in South China Sea. In this experiment, guaiazulene-2,9-dione was quantitatively synthesized with an optimized one-step bromine oxidation method using guaiazulene as the raw material. The key reaction condition including reaction time and temperature, drop rate of bromine, concentration of aqueous THF solution, respective molar ratio of guaiazulene to bromine and acetic acid, and concentration of guaiazulene in aqueous THF solution, were investigated individually at five levels each for optimization. Combined with the verification test to show the absolute yield of each optimization step, the final optimal condition was determined as: when a solution of 0.025 mmol m L-1 guaiazulene in 80% aqueous THF was treated with four volumes of bromine at a drop rate of 0.1 m L min-1 and four volumes of acetic acid at-5℃ for three hours, the yield of guaiazulene-2,9-dione was 23.72%. This was the first report concerning optimized one-step synthesis to provide a convenient method for the large preparation of guaiazulene-2,9-dione.