The content of dimethylallylamine was determined using glacial acetic acid as solvent, acetic-formic mixture as an anhydrite, perchloric acid-glacial acetic acid as titrant, and 1% crystal violet in acetic acid as ind...The content of dimethylallylamine was determined using glacial acetic acid as solvent, acetic-formic mixture as an anhydrite, perchloric acid-glacial acetic acid as titrant, and 1% crystal violet in acetic acid as indicator in the presence of methylamine and dimethylamine The influences of inert constituents and water on the titration were investigated, and a complete analytical method was determined. The results showed that the determination error of total amines increased with water increasing, while the effect of water on the determination of dimethylallylamine was little when the amount of water was within 5%, the relative error was generally within 1%, and that the end-point was acutely when about 10% chloroform was added. Compared with gas chromatography, this method is simple, convenient and accurate.展开更多
For the mass transfer to single drops during the stage of steady buoyancy-driven motion, experimental measurement is complicated with the terminal effect of additional mass transfer during drop formation and coalescen...For the mass transfer to single drops during the stage of steady buoyancy-driven motion, experimental measurement is complicated with the terminal effect of additional mass transfer during drop formation and coalescence at the drop collector. Analysis reveals that consistent operating conditions and experimental procedure are of critical significance for minimizing the terminal effect of drop coalescence on the accuracy of mass transfer measurements. The novel design of a totally-closed extraction column is proposed for this purpose, which guarantees that the volumetric rate of drop phase injection is exactly equal to that of withdrawal of drops. Tests in two extraction systems demonstrate that the experimental repeatability is improved greatly and the terminal effect of mass transfer during drop coalescence is brought well under control.展开更多
文摘The content of dimethylallylamine was determined using glacial acetic acid as solvent, acetic-formic mixture as an anhydrite, perchloric acid-glacial acetic acid as titrant, and 1% crystal violet in acetic acid as indicator in the presence of methylamine and dimethylamine The influences of inert constituents and water on the titration were investigated, and a complete analytical method was determined. The results showed that the determination error of total amines increased with water increasing, while the effect of water on the determination of dimethylallylamine was little when the amount of water was within 5%, the relative error was generally within 1%, and that the end-point was acutely when about 10% chloroform was added. Compared with gas chromatography, this method is simple, convenient and accurate.
基金the National Natural Science Foundation of China (No. 29792074, No. 29836130) and SINOPEC.
文摘For the mass transfer to single drops during the stage of steady buoyancy-driven motion, experimental measurement is complicated with the terminal effect of additional mass transfer during drop formation and coalescence at the drop collector. Analysis reveals that consistent operating conditions and experimental procedure are of critical significance for minimizing the terminal effect of drop coalescence on the accuracy of mass transfer measurements. The novel design of a totally-closed extraction column is proposed for this purpose, which guarantees that the volumetric rate of drop phase injection is exactly equal to that of withdrawal of drops. Tests in two extraction systems demonstrate that the experimental repeatability is improved greatly and the terminal effect of mass transfer during drop coalescence is brought well under control.