This paper presents The investigation of laser resonance ionization mass spectroscopy of lutetium with our laser ionization mass spectrometry system manufactured by our own. The optimum radius of laser focal spot over...This paper presents The investigation of laser resonance ionization mass spectroscopy of lutetium with our laser ionization mass spectrometry system manufactured by our own. The optimum radius of laser focal spot overlapped with atomic beam is calculated theoretical.Lutetium ionic signal at The rate of 1.8 ×105 s- 1is detected The Sample she of 1 μg lutetium.. With laser resonance ionization and The of atomizer,it is possible that The detection ho reaches 106 atoms. The effect of laser-induce isotopic discrimination on The measurement of isotope ratio is discussed. It is proposed that laser bandwidth and wavelength tuning effects are The main factors of deviation of lutetium isotopic ratios with this broad bandwidth laser.展开更多
The state-of-art of the isotopic analysis technique in the laser resonance ionization mass spectrometry (LRIMS) in northwest institute of nuclear technology was founded. Main technique obstacles and feasible resolvent...The state-of-art of the isotopic analysis technique in the laser resonance ionization mass spectrometry (LRIMS) in northwest institute of nuclear technology was founded. Main technique obstacles and feasible resolvents with the application of 1,RIMS in isotopic analysis were discussed. In order to obtain accurate isotope ratio determined by LRIMS, the new method combined with experimental process and correction factor calculated by numerical computation method was proposed and applied to measure lutetium isotope ratio. The natural lutetium isotope ratio determined by use of this method was less than 0.8% by thermal ionization mass spectrometry (TIMS), This method can also be applied to determine abundance ratios of some other elements.展开更多
文摘This paper presents The investigation of laser resonance ionization mass spectroscopy of lutetium with our laser ionization mass spectrometry system manufactured by our own. The optimum radius of laser focal spot overlapped with atomic beam is calculated theoretical.Lutetium ionic signal at The rate of 1.8 ×105 s- 1is detected The Sample she of 1 μg lutetium.. With laser resonance ionization and The of atomizer,it is possible that The detection ho reaches 106 atoms. The effect of laser-induce isotopic discrimination on The measurement of isotope ratio is discussed. It is proposed that laser bandwidth and wavelength tuning effects are The main factors of deviation of lutetium isotopic ratios with this broad bandwidth laser.
文摘The state-of-art of the isotopic analysis technique in the laser resonance ionization mass spectrometry (LRIMS) in northwest institute of nuclear technology was founded. Main technique obstacles and feasible resolvents with the application of 1,RIMS in isotopic analysis were discussed. In order to obtain accurate isotope ratio determined by LRIMS, the new method combined with experimental process and correction factor calculated by numerical computation method was proposed and applied to measure lutetium isotope ratio. The natural lutetium isotope ratio determined by use of this method was less than 0.8% by thermal ionization mass spectrometry (TIMS), This method can also be applied to determine abundance ratios of some other elements.