In order to estimate and detect the surface defect depth of metals, the transmission method of laser ultrasonic surface waves is used in this work. The laser ultrasonic detection platform taking use of thermoelastic m...In order to estimate and detect the surface defect depth of metals, the transmission method of laser ultrasonic surface waves is used in this work. The laser ultrasonic detection platform taking use of thermoelastic mechanism as acoustic signal excitation method and interference receiver as acoustic signal receiver method was built, by which B-scan images of detected specimens with surface defects were collected to establish the relationship between the transmission coefficient and depth of the surface defect. Experimental results show that the amplitude of transmitted acoustic signal is related to the depth of surface defect. At last, a fitted curve of transmission coefficient using measured experimental data is obtained to estimate depth of surface defect on the 6061 aluminum alloy. Furthermore, a surface defect depth of 0.3 mm is estimated by the fitting curve with an estimated error of 16%. Therefore, a experimental method using the transmission method by laser ultrasonic is presented in this paper.展开更多
基金National Natural Science Foundation of China(No.11604304)High School Science and Technology Innovation Project of Shanxi ProvinceApplied Basic Research Project of Shanxi Province(Nos.201701D221127,201801D121160)
文摘In order to estimate and detect the surface defect depth of metals, the transmission method of laser ultrasonic surface waves is used in this work. The laser ultrasonic detection platform taking use of thermoelastic mechanism as acoustic signal excitation method and interference receiver as acoustic signal receiver method was built, by which B-scan images of detected specimens with surface defects were collected to establish the relationship between the transmission coefficient and depth of the surface defect. Experimental results show that the amplitude of transmitted acoustic signal is related to the depth of surface defect. At last, a fitted curve of transmission coefficient using measured experimental data is obtained to estimate depth of surface defect on the 6061 aluminum alloy. Furthermore, a surface defect depth of 0.3 mm is estimated by the fitting curve with an estimated error of 16%. Therefore, a experimental method using the transmission method by laser ultrasonic is presented in this paper.