期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
煤气发生炉中火层的重要性
1
作者 李耀刚 《化肥工业》 CAS 2002年第1期37-38,共2页
在煤气发生炉的生产操作中 ,出现火层吹翻、有效气体成份低、流炭等现象都与火层有关。
关键词 煤气发生炉 温度 火层厚度 炉箅
下载PDF
阻火器的设计和选用 被引量:12
2
作者 高岭 高庆贵 《化工设计》 CAS 2011年第2期24-27,1,共4页
阻火器的设计和选用直接影响化工生产操作和安全。本文从工作原理、分类、设计计算和选用等方面,论述阻火器设计、选用方法和应注意的因素。
关键词 最大试验安全间隙(MESG) 焰速度 熄灭直径 火层厚度 器压力降
下载PDF
Elevated temperature oxidation behavior of HVOF sprayed TiB_2 cermet coating 被引量:7
3
作者 Behnam LOTFI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2010年第2期243-247,共5页
Oxidation behaviors of Ni(Cr)-TiB2 coating deposited by HVOF technique were studied at 800,900 and 1 000℃in air. The microstructures of as-sprayed and oxidized coatings were characterized by X-ray diffractometry(XRD)... Oxidation behaviors of Ni(Cr)-TiB2 coating deposited by HVOF technique were studied at 800,900 and 1 000℃in air. The microstructures of as-sprayed and oxidized coatings were characterized by X-ray diffractometry(XRD)and scanning electron microscopy(SEM).After oxidation at 800℃,a thin and adherent oxide layer was formed on the surface of the coating.With increasing exposure temperature,the thickness of the oxide layer increased;and at 1 000℃the oxide layer separated from the coating.Investigation of the kinetics of oxidation by using the thermogravimetric analysis(TGA)technique shows a parabolic oxidation rate. 展开更多
关键词 TIB2 cermet coating thermal spraying oxidation
下载PDF
矿用防爆柴油机栅栏式排气阻火器结构优化 被引量:1
4
作者 邹润 杨世文 +3 位作者 苏铁熊 韩文艳 张翼 申进杰 《煤矿安全》 CAS 北大核心 2017年第1期103-106,共4页
采用FLUENT软件对栅栏式排气阻火器的二维模型进行数值模拟,分析阻火器的阻火层厚度、栅栏间隙对淬熄距离和压力损失的影响。对模拟结果进行回归分析,得到了优化目标的回归模型;采用线性加权法合并淬熄距离和压力损失的回归模型,得到多... 采用FLUENT软件对栅栏式排气阻火器的二维模型进行数值模拟,分析阻火器的阻火层厚度、栅栏间隙对淬熄距离和压力损失的影响。对模拟结果进行回归分析,得到了优化目标的回归模型;采用线性加权法合并淬熄距离和压力损失的回归模型,得到多目标函数;在一定约束条件下,对多目标函数进行最优求解。结果表明,阻火层厚度变大和栅栏间隙变小时,淬熄距离变小,压力损失变大;阻火层厚度为50 mm,栅栏间隙为0.25 mm时,栅栏式阻火器火焰淬熄距离和压力损失最小。 展开更多
关键词 防爆柴油机 栅栏式阻 火层厚度 栅栏间隙 淬熄距离
原文传递
Rational concrete cover of prestressed concrete beams and slabs for fire resistance
5
作者 郑文忠 侯晓萌 许名鑫 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第5期593-600,共8页
As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire ... As the influence of the ratio of the characteristic value of structural resistance to that of frequent combination effect, K, on the thickness of concrete cover of prestressed concrete (PC) beams and slabs for fire resistance is not considered sufficiently in design criteria for concrete structures in China and other countries at present, numerical analyses were carried out by ANSYS software on unbonded prestressed concrete (UPC) oneway simply-supported and continuous slabs and beams, and bonded PC simply-supported and continuous beams subjected to fire in 186 cases. In the analysis, K, section dimensions and the thickness of concrete cover are regarded as independent variables and some calculation parameters determined by trial and error based on test resuits. Calculation formula for fire endurance of UPC simply-supported and continuous slabs was proposed, and the recommended thicknesses of cover of PC beams and slabs was presented in consideration of the influence of K and section dimensions as well as fire endurance requirements. Comparison analysis of relevant design criterions in China and other countries was performed to verify the rationale of the proposed values. 展开更多
关键词 prestressed concrete (PC) beams and slabs fire resistance fire endurance COVER
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部