Although FireWire-based memory acquisition method has been introduced for several years, the methodologies are not discussed in detail and still lack of practical tools. Besides, the existing method is not working sta...Although FireWire-based memory acquisition method has been introduced for several years, the methodologies are not discussed in detail and still lack of practical tools. Besides, the existing method is not working stably when dealing with different versions of Windows. In this paper, we try to compare different memory acquisition methods and discuss their virtues and disadvantages. Then, the methodologies of FireWire-based memory acquisition are discussed. Finally, we give a practical implementation of FireWire-based acquisition tool that can work well with different versions of Windows without causing BSoD problems.展开更多
A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is t...A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants.展开更多
In micro electrical discharge machining (micro EDM), it is difficult for servo controlling the narrow discharge gap with the characters of non-linear and quick change. In this paper, aiming at solving the problems a...In micro electrical discharge machining (micro EDM), it is difficult for servo controlling the narrow discharge gap with the characters of non-linear and quick change. In this paper, aiming at solving the problems above, a self-adaptive fuzzy controller with formulary rule (SAFCFR) is presented based on the dual feedbacks composed by gap electric signal and discharge-ratio statistics. To ensure the properties of self-optimizing and fast stabilization, the formulary rule was designed with a tuning factor. In addition, the fast-convergence algorithms were introduced to adjust control target center and output scale factor. In this way, the normal discharge ratio can tend to the highest value during micro-EDM process. Experimental results show that the proposed algorithms are effective in improving the servo-control performance. According to the drilling-micro-EDM experiments, the machining efficiency is improved by 20% through applying SAFCFR. Moreover, SAFCFR is a prompt way to optimize parameters of discharge-gap servo control.展开更多
The in-orbit verification of a refueling test system has been completed successfully.The test system based on a surface tension tank was developed by the Beijing Institute of Control Engineering(BICE),CAST and launc...The in-orbit verification of a refueling test system has been completed successfully.The test system based on a surface tension tank was developed by the Beijing Institute of Control Engineering(BICE),CAST and launched into spacewith the Tianyuan 1 satellite aboard a LM-7 carrier rocket on June 25.The lifetime of any spacecraft is constrained by fuel it carried.展开更多
基金This work is supported by the National Natural Science Foundation of China (61070163) and Shandong Natural Science Foundation (Y2008G35).
文摘Although FireWire-based memory acquisition method has been introduced for several years, the methodologies are not discussed in detail and still lack of practical tools. Besides, the existing method is not working stably when dealing with different versions of Windows. In this paper, we try to compare different memory acquisition methods and discuss their virtues and disadvantages. Then, the methodologies of FireWire-based memory acquisition are discussed. Finally, we give a practical implementation of FireWire-based acquisition tool that can work well with different versions of Windows without causing BSoD problems.
基金Project(217/s/458)supported by Azarbaijan Shahid Madani University,Iran
文摘A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants.
基金Supported by the National High Technology Research and Development Program of China (No. 2007AA04Z346) , the National Natural Science Foundation of China ( No. 50905094) and China Postdoctoral Science Foundation ( No. 20080440378, 200902097).
文摘In micro electrical discharge machining (micro EDM), it is difficult for servo controlling the narrow discharge gap with the characters of non-linear and quick change. In this paper, aiming at solving the problems above, a self-adaptive fuzzy controller with formulary rule (SAFCFR) is presented based on the dual feedbacks composed by gap electric signal and discharge-ratio statistics. To ensure the properties of self-optimizing and fast stabilization, the formulary rule was designed with a tuning factor. In addition, the fast-convergence algorithms were introduced to adjust control target center and output scale factor. In this way, the normal discharge ratio can tend to the highest value during micro-EDM process. Experimental results show that the proposed algorithms are effective in improving the servo-control performance. According to the drilling-micro-EDM experiments, the machining efficiency is improved by 20% through applying SAFCFR. Moreover, SAFCFR is a prompt way to optimize parameters of discharge-gap servo control.
文摘The in-orbit verification of a refueling test system has been completed successfully.The test system based on a surface tension tank was developed by the Beijing Institute of Control Engineering(BICE),CAST and launched into spacewith the Tianyuan 1 satellite aboard a LM-7 carrier rocket on June 25.The lifetime of any spacecraft is constrained by fuel it carried.